RAPT Pill Hydrometer & Thermometer Quick Start Guide
Pill
Hydrometer & Thermometer
KL20596
Quick Start Guide
KegLand Distribution PTY LTD
1
11
www.KegLand.com.au
Last Updated 7/12/2021 13:32 PM
Page
of

Advertisement

Table of Contents
loading

Summary of Contents for KegLand RAPT Pill

  • Page 1 RAPT Pill Hydrometer & Thermometer Quick Start Guide Pill Hydrometer & Thermometer KL20596 Quick Start Guide KegLand Distribution PTY LTD www.KegLand.com.au Last Updated 7/12/2021 13:32 PM Page...
  • Page 2 StellarSan Phosphoric Acid. The battery may come preinstalled in the RAPT Pill Hydrometer. If that is the case you will need to remove the blue plastic strip which prevents the battery from completing a connection and draining during shipping. Battery Installation (If required) Only use KegLand approved 18650 rechargeable Lithium-ion batteries (KL26734).
  • Page 3: Led Indicators

    RAPT Pill Hydrometer & Thermometer Quick Start Guide LED INDICATORS The RAPT Pill Hydrometer features two onboard LEDs CHARGING LED (RED): • Solid Red – On when plugged in to USB charger ESP LED (GREEN): • Flashing Green – flashes when the captive portal is enabled •...
  • Page 4 SIGN UP FOR A RAPT ACCOUNT To utilise the Wi-Fi connectivity of the RAPT Pill Hydrometer you will need to sign up for an account on the RAPT portal. This will allow you to track and monitor your specific gravity and fermentation temperature in real time.
  • Page 5 4. Choose the RAPT device you wish to pair with 5. Click Save to finish. NOTE: Only ONE RAPT Pill will be displayed on the paired device (such as a RAPT Fermentation Chamber). The telemetry for each Pill is viewable in the RAPT Portal separately.
  • Page 6 RAPT Pill Hydrometer & Thermometer Quick Start Guide INSTALL THE CIRCUIT BOARD AND ASSEMBLE YOUR DEVICE When installing the circuit board into the housing it is important to insert the circuit board in the correct orientation to ensure the correct weight distribution for accurate readings. The yellow end of the circuit board should be inserted into the yellow housing as shown below.
  • Page 7: Sleep Mode

    For calibration steps refer to the Calibration section below. 1. Submerge your RAPT Pill hydrometer in a glass of pint water to test for leaks prior to placing into your fermenter. 2. Sanitise your RAPT Pill Hydrometer with an approved sanitiser such as...
  • Page 8: Standard Calibration

    1. Plug your Rapt Pill into a charger or computer with a USB-C cable (not included) 2. On your smart phone or tablet, open your Wifi settings and connect to the "RAPT Pill XXX" access point (AP) using the password "kegland1". You may not need to enter the password if you have previously connected your device to the Pill’s Wifi.
  • Page 9: Advanced Calibration

    RAPT Pill Hydrometer & Thermometer Quick Start Guide 2: Advanced Calibration The advanced calibration mode can give greater accuracy across a wider range Advanced calibration is also quite quick and easy, and can provide a more accurate result than Standard Calibration. It is the same procedure as standard calibration, but in addition to water at 1.000, have a solution of a known gravity prepared.
  • Page 10 RAPT Pill Hydrometer & Thermometer Quick Start Guide 2. Repeat this step for solutions of different gravity, making a note of the angle and the gravity at each step. It is easiest to dilute the starting solution in steps of approximately 10 points.
  • Page 11: Troubleshooting

    If you need hardware support, please contact your nearest distributor. The RAPT Pill Hydrometer & Thermometer comes with a 12-month warranty when sold in Australia. To lodge a warranty claim in Australia please forward as many visual pieces of supporting...