  • Page 2 Manual instruction Blood Pressure Monitor MM – 210 ESATTO...
  • Page 3: Table Of Contents

    Contents 1. Before Using This Device ..................23 2. Important Safety Information and Precautions ............23 3. Specifications ......................24 4. About Blood Pressure ..................... 24 5. About blood pressure monitor ................. 25 6. Buttons ........................25 7. Display ........................25 8.
  • Page 4: Before Using This Device

    Thank you for purchasing our product. Please read manual instruction before use. 1. Before Using This Device INDICATIONS FOR USE: This blood pressure monitor is intended to be used to measure blood pressure and pulse rate from upper arm by using the oscillometric method at home. This device is intended for use on adults only and is not for use on groups such as neonatal babies, children, pregnant women, or pre-eclamptic patients.
  • Page 5: Specifications

    3. Specifications. Model MM 210 Esatto Measurement Method Oscillometric Display Measurement Range Pressure: 0 to 299 mmHg Pulse: 40 to 180 beats/minute Accuracy Pressure: Within 3 mmHg Pulse Rate: Within 5% of reading Inflation Automatic inflation by pump Deflation Automatic rapid deflation Pressure Detection Semiconductor pressure sensor Memory...
  • Page 6: About Blood Pressure Monitor

    Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/ stethoscope auscultatory method, within the limits prescribed by European Society of Hypertension International Protocol revision2010 for the validation of blood pressure measuring devices in adults. An irregular heartbeat rhythm is defined as a rhythm that is more than25% slower or 25% faster from the average rhythm detected while the device is measuring the systolic blood pressure and the diastolic blood pressure.
  • Page 7: Battery Installation

    8. Battery installation a. Take off the battery cover on the back of this device.(Figure 1) Figure 1 b. Insert three AA alkaline batteries according to the + and – markings. (Figure 2) Figure 2 c. Snap the battery cover on, ensure it clicks into place. 9.
  • Page 8: Measurements Notes

    12. Measurements notes • After measurements, the blood pressure monitor turns off after 2 minutes after pressing the last button. • To stop the measurement, press the START/STOP button. • Between measurements, keep a minimum break of 5 minutes and try to maintain one body position and breathe evenly and calmly.
  • Page 9: Measurement

    16. Measurement a. This device should be used on bare skin. If necessary, loosely roll up your sleeve to expose arm. Note that your arm cannot be tightened by your sleeve. b. With the hose down the inside of your arm and the bottom of the cuff approx. 1~2cm above your elbow, wrap the cuff around your arm.
  • Page 10: Special Function - Determining The Average Of The Last 3 Measurements

    d. If you desire to delete all stored measurements, press and hold “SET” under the Memory- recall status until “dEL no” is displayed with “no” flashing. Press and release “SET” to switch to “dEL YES” with “YES” flashing. Press “START/STOP” with “dEL YES” to confirm clearing the memory and then blank entry appears on screen, or press “START/STOP”...