General Information
Incorporated with advanced leak detection technology, CLD-100 is
an ideal and economic halogen leak detector.Compact in appearance,
it is stable and easy to operate.
Detect all kinds of halogen refrigerants
Sensitivity can be adjusted at any time and the detector can be adjusted
automatically to the best state of detection.
Inner precise IC with ultra-low circuit consumption offers more stable
function and lengthens battery life.
Two-color visual display of battery voltage.
Excellent sensor brings high sensitivity and longer service time.
All manuals and user guides at all-guides.com
General Information
Operating temperature:
0℃ to 52℃(30℉ to 125℉)
Maximum sensitivity:
6 gr/yr, for all halogenated refrigerants
Battery life:
approximately 20 hours in normal use.
Response time:
instantaneous.
Work mode:
continuous, no limitation.
Fixed probe length:
20cm.
Warm-up time:
approximately 6 seconds.
Reset time:
2-10 seconds.
Power supply:
6V DC, four AAA excellent batteries.
Detection Range
The CLD-100 may also be used to detect leaks in other systems and storage
/recovery containers.It will respond to all halogenated (including Chlorine and
Fluorine) refrigerants. This includes but is not limited to:
CFCs
e.g.R12,R11,R500,R503 etc.
HCFCs
e.g.R22,R123,R124,R502 etc.
HFCs
e.g.R134a,R404a,R125 etc.
Blends such as AZ-50, HP62, MP39 etc.
Detect Ethylene Oxide gas leaks in hospital sterilizing equipment
(it will detect the halogenated carrier gas).
Detect SF-6 in high voltage circuit breakers.
Detect most gases that contain Chlorine, Fluorine and Bromine(ha
logen gases).
Detect cleaning agents used in dry cleaning applications such as
perchloroethylene.
Detect halogen gases in fire-extinguishing system.
Battery lndicator
The forepart light of panel indicates the leak and the battery voltage.
GREEN
Battery voltage is normal, sufficient for proper operation.
ORANGE
Battery voltage is approaching the lower threshold for
operation.
Replace them as soon as possible.

Advertisement

loading

Summary of Contents for Elitech CLD-100

  • Page 1 Excellent sensor brings high sensitivity and longer service time. Detection Range The CLD-100 may also be used to detect leaks in other systems and storage /recovery containers.It will respond to all halogenated (including Chlorine and Fluorine) refrigerants. This includes but is not limited to: CFCs e.g.R12,R11,R500,R503 etc.