Table of Contents

Advertisement

1. Set MMSI ID .............................................................................................................. 5
2. SSB mode ................................................................................................................... 5
3. DSC mode .................................................................................................................. 5
4. Distress transmit ...................................................................................................... 6
1. Selection of Channel .............................................................................................. 6
2. Selection of Frequency ......................................................................................... 6
3. ARQ mode ................................................................................................................. 6
4. FEC mode ................................................................................................................... 6
Chapter 1. Overview ............................................................................................................. 7
1.1. Features ................................................................................................................... 7
1.2. Basic Components ............................................................................................... 8
Chapter 2. Specifications ..................................................................................................... 9
2.1. General specification .......................................................................................... 9
2.2. MF/HF Transmitter............................................................................................... 9
2.3. MF/HF Receiver .................................................................................................... 9
2.4. DSC (Digital Selective Calling) W/K Receiver ......................................... 10
2.5. MF/HF Control .................................................................................................... 10
2.6. Digital Selective Calling (DSC) ...................................................................... 10
2.7. Narrow band direct Printing (NBDP) ......................................................... 11
2.8. Printer (DPU-414) .............................................................................................. 11
2.9. Printer (OKI) ......................................................................................................... 11
Chapter 3. Power Supply ................................................................................................... 12
3.1. Power On .............................................................................................................. 12
3.2. Operation by AC power .................................................................................. 12
3.3. Operation by DC (BATTERY) power ........................................................... 12
3.4. BATTERY Charging ............................................................................................. 12
Chapter 4. Front Panel ....................................................................................................... 13
4.1. About Button, Knob, Lamp ............................................................................ 13
4.2. LCD display ........................................................................................................... 14
4.3. LCD display flow ................................................................................................ 15
Chapter 5. SSB (TEL) mode ............................................................................................... 16
5.1. SSB Mode ............................................................................................................. 16
5.2. SSB Menu .............................................................................................................. 16
Contents
1.1. Self-ID ..................................................................................................... 5
2.1. Channel Selection .............................................................................. 5
2.2. Frequency Selection ......................................................................... 5
2.3. TX, RX ..................................................................................................... 5
3.1. Channel Selection .............................................................................. 5
3.2. Frequency Selection ......................................................................... 5
3.3. Call ........................................................................................................... 6
3.4. DSC Message RX Auto Reply ....................................................... 6
(1) Scan Type Set...................................................................................... 16
(2) Scan Channel Set .............................................................................. 16
(3) Scan Frequency Set .......................................................................... 16
SRG-3150DN Rev.1.1(080409)
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRG-3150DN and is the answer not in the manual?

Questions and answers

Summary of Contents for Samyung ENC SRG-3150DN

  • Page 1: Table Of Contents

    Contents SRG-3150DN Rev.1.1(080409) SRG-3150DN How to operate basic function and Distress transmitting 1. Set MMSI ID ......................5 1.1. Self-ID ..................... 5 2. SSB mode ........................5 2.1. Channel Selection ................5 2.2. Frequency Selection ................. 5 2.3. TX, RX ..................... 5 3.
  • Page 2 11.3. How to Charge ....................36 11.4. In case of over current .................. 36 Chapter 12. Circuit explain ....................37 12.1. Overview of SRG-3150DN ................37 12.2. CONTROL CIRCUIT (T-1110) ............... 38 (1) MF/HF RX Circuit ................38 (2) MF/HF TX Circuit ................38 (3) Local Synthesizer Circuit ..............
  • Page 3 12.6. Front Panel (T-1114) ..................41 12.7. Function Diagram of Rear Side ..............42 Chapter 13. NBDP Terminal ....................43 13.1. NBDP Terminal Main Unit ................43 13.2. Initial Display of Telex (NBDP) mode ............43 (1) Initial screen function explanation ..........43 (2) Initial screen function button explanation ......
  • Page 4 15.1. Overview ......................54 15.2. Measuring Instrument ................... 54 15.3. Maintenance & repair of SRG-3150DN ..........54 (1) Antenna ....................54 (2) Power Supply ..................54 (3) Transmitter ................... 54 (4) Receiver ....................54 (5) DSC Receiver ..................54 (6) Switch and Display ................55 15.4.
  • Page 5: Srg-3150Dn How To Operate Basic Function And Distress Transmitting

    SRG-3150DN How to operate basic function and Distress transmitting 1. Set MMSI ID (Maritime Mobile Service Identity) 2.2. Frequency Selection • 1)Press twice( )and select to [TX] Press button and ON, It stop at the below Input frequency by [No. button]...
  • Page 6: Call

    3.3. Call 4. Distress transmit • Press to go to [DSC] mode 4.1. Transmit signal(DISTRESS) select to the channel by dial [CH] Emergency Transmitter KEY (1) Hold on 3 seconds [DISTRESS] and then transmit signal. 3.4. DSC Message RX Auto Reply •...
  • Page 7: Chapter 1. Overview

    W/K Receiver, DSC, Distress alarm telephone is built which relied on a manual Morse code system on in SRG-3150DN, You are able to use itself without 500 kHz and voice radiotelephony on Channel 16 NBDP terminal(SN-100). NBDP function is worked and 2182 kHz.
  • Page 8: Basic Components

    1.2. Basic Components • This equipment is composed of SRG-3150DN and SN-100(NBDP), each item is made by functional PCB and sorted by standard and option. << Standard Components List >> Description Model Q’ty Remark MF/HF-DSC 송 수신기 SRG-3150DN 1set MAIN BOARD...
  • Page 9: Chapter 2. Specifications

    Chapter 2. Specifications 2.1. General specification • This radio equipment SRG-3150DN has been (7) Number of Channels: SSB x 299, ITU x 271, DSC x 19 tested by the recommendation standard of IMO. (8) Modulation type: (1) Power Supply (SP-1250ADC)
  • Page 10: Dsc (Digital Selective Calling) W/K Receiver

    (7) Clearness: ±120Hz (9) SPURIOUS RESPONSE: (8) Overall Distortion & Noise : With a wanted signal of 10㎶ and 31.6㎷ zero With an input voltage of 30uv, the ratio between modulated interference signal which excludes the an audio frequency output of 1000Hz and its range within 750hz of the wanted signal, the unwanted component is more than 20db.
  • Page 11: Narrow Band Direct Printing (Nbdp)

    2.7. Narrow band direct Printing (NBDP) (1) Protocol • Diameter : 48mm CCIR recommendation 625.476-4.490491.492-3 • Length : about 28m & CCIR F130 (2) Calling mode : (5) Etc Individual and group calling with 5 digits and 9 • Power Supply : DC 6.5 ~ 13.6V digits select call number.
  • Page 12: Chapter 3. Power Supply

    Operation by DC (BATTERY) power (3) OFF MODE: Set the middle of switch between AUTO & NORMAL. • When AC power is disconnected, the SRG-3150DN switches to DC operation and [DC] LED on MF/HF control panel will light up automatically.
  • Page 13: Chapter 4. Front Panel

    Chapter 4. Front Panel 4.1. About Button, Knob, Lamp < SRG-3150DN Main Unit > : Selecting "CH" "TX" "RX" in ①. KEY Panel Order. (Be available to select Channel and TX/RX Frequency) ②. Front Panel(LCD) - Mode / Frequency / Channel : Select ATT in order.
  • Page 14: Lcd Display

    : ON/OFF AGC. (14) LED Display (Display LCD left-bottom) [DISTS]: When receive a Distress signal by W/K Adjust automatically gain that bundle receiver or transmit a Distress alarm signal, be amplification of receiver. flickered LED indicator. (Auto Gain Control: It means that system maintain [OTHER]: when receive DSC without DISTRESS to regardless of changing of strength that input signal, be flickered Green LED Indicator.
  • Page 15: Lcd Display Flow

    FIB: 100W) MID : SRG-3150DN (J3E:100W, F1B:100W) MAIN DISPLAY LOW : SRG-3150DN (J3E:50W, F1B:75W) f) F: Display is in use or not. g) AC : Indicate currency situation to POWER SUPPLIER (SP-1250ADC). : AC Power Supply. : battery power supply.
  • Page 16: Chapter 5. Ssb (Tel) Mode

    Chapter 5. SSB (TEL) mode 5.1. SSB Mode [▲][▼] Move, and select to wanted function, Press button on front panel, and then go to SSB mode. Selected. [Number button] Input the value. Set up. Press to back to main screen. [Ref.] ☞...
  • Page 17: Lcd Contrast Set

    6.Tx Power is selected. The below box shows. Select HIGH / MID / LOW b) If Tx Power HIGH, Display "HIGH", SRG-3150DN(J3E:150W, FIB:100W) MID, display "MID", SRG-3150DN(J3E:100W, F1B:100W) LOW, display "LOW". SRG-3150DN(J3E:50W, F1B:75W) ① [1.Tuning Clear]: Clear all the memory tuned.
  • Page 18: Additional Functions (Itu Channel, Am Mode, Etc.,)

    5.3. Additional Functions ⑥ [6.ADC Value]: RXG in first display – Show (ITU selecting ON/OFF. Channel, AM mode, Etc.,) 6. ADC Value is selected. (1) ITU Channel [CH401 - CH2510], it can be Press, and then can select IC, ANT, SWR, VOLT. selected by [CH] and [Number] on SSB Mode, if it is [Ref.] ☞...
  • Page 19: Chapter 6. Digital Selective Calling (Dsc) Mode

    Chapter 6. Digital selective calling (DSC) mode 6.1. The selection of DSC mode Press, display can edit msg. on the Set DSC Mode by on the front Panel as screen. (Or can be edited what you want.) follow. ① [FORMAT]: A kind of calling. Distress calling(fixed) Distress : ②...
  • Page 20: Individual Msg Edit

    ④ [DIST-UTC]: Set time of distress. ① [TX-Freq]: Set TX frequency. [▲][▼] Move to DIST-UTC [▲][▼] Move to TX-Freq The below box shows. The below box shows. - - : - - - : Time of Distress(00:00 - 23:59) 2,187.50 4,207.50 [Number.
  • Page 21: Group Msg Edit

    ⑦ [WORK FRQ]: Operational frequency. c) After setting items, press [▲][▼] Move to WORK FRQ “individual call” signal transmits. Selected. [Number. button] Input TX frequency. When response signal received, communication can be possible with the voice Set up. communication frequency. [Number.
  • Page 22: Geography Msg Edit

    ④ [PARTY ID] : Input the ID of counter party. [Ref.] ☞ How to register frequency that communicate with voice: MENU>9.SYSTEM [▲][▼] Move to PARTY_ID SET>5.ID/FR/TEL Set>3.Work Frequency Selected. Edit and register. [Number. button] Input ID. Set up. c) After setting items, press and “group call”...
  • Page 23 c) Function Keys [Ref.] ☞ Indicate the frequencies which is memorized by user in DSC mode CH7~19. ① After inputting data press and it is saved. ② [FORMAT]: A kind of calling. local calling(fixed) Geography : ②select [PARTY-ID] press and registered ID list shows select by [▲][▼] ③...
  • Page 24 ④ [PARTY AD]: Input location data [▲][▼] Move to PARTY_AD [Ref.] ☞ φ = Latitude Selected. λ = Longitude N _ _ : North latitude (00 - 90) (φ ) Δφ = Latitude Range S _ _ : South latitude (00 - 90) (φ...
  • Page 25: Auto/Semi-At Msg Edit

    (5) Auto/Semi-AT msg edit ⑤ [TEL CMD1]: Set Telecommand1. communicating connected with [▲][▼] Move to TEL CMD1 telephone. The below box shows. 5.Auto/Semi-AT mag edit is selected. The below box shows. CH = 300 (NO DATA) CH = 301 (NO DATA) CH = 302 (NO DATA) ……...
  • Page 26: Dist Ack/Rly Msg Edit

    b) It is memory channel using from 400 to 499 as ③ Select[WORK FRQ] press and registered right on the top. frequency list shows select by [▲][▼] [Ref.] ☞ [▲] [▼] : Moving up and down with 1 step channel. [◀][▶] : Moving up and down with 10 step channels.
  • Page 27 ④ [PARTY ID] : Input the ID of counter party. ⑧ [POSITION]: Input the Position of the vessel In case of selecting [Individual] in [FORMAT], in distress. input ID [▲][▼] Move to POSITION [▲][▼] Move to PARTY_ID The below box shows. Selected.
  • Page 28: Ordinary Ack Msg Edit

    (7) Ordinary ack msg edit (9) System Set a) In case of common answer call. a) in case of setting the value of SYSTEM. 7. Ordinary ack msg edit is selected. 9. System Set is selected. The below box shows. The below box shows.
  • Page 29 input ship’s name: ③ [3.Dist TEL-CMD]: Set Telecommand. “SAMYUNG”, “101010000” 3. Dist TEL-CMD is selected. Press to change [▶] [▶] [▶] [J3E TP] / [FIB/J2B T]. [▶] [▶] [▶] ④ [4.LAT / LON Set]: Set Lat/Lon of GPS by hand-operation. It is input as below 4.
  • Page 30 ⑥ [6.WKR Scan Set] ⑩ [0.Etc. Set]: Set etcetera system. 6. WKR Scan Set is selected. 0. Etc. Set is selected. The below box shows. The below box shows. 2187.5 4207.5 6312.0 8414.5 12577.5 16804.5 [▲][▼] The frequency is selected. Press to change [on] / [off].
  • Page 31 [5. DSC Msg Receive]: Receive DSC message. [8. Dist-Key Test]: [DISTRESS] button Test. 5. DSC Msg Receive is selected. 8. Dist-Key Test is selected. Press to change [on] / [off]. The below box shows. [Ref.] ☞ message receiving is not available. Press Distress Key [DISTRESS] for 3 seconds and the [6.
  • Page 32: Chapter 7. Transmitter Of Distress Signal

    Chapter 7. Transmitter of distress signal 7.1. Test of Distress alert signal (2) If don’t have a answer, flicker[DISTS] LED and shown following screen then after minutes(3min 30sec ~4min 40sec), transmit channel 1 ~ 6. (1) Hold on 3 seconds [DISTRESS] in the panel, flicker DISTS] LED with alarm and after 3 seconds shown following screen, [DISTS] LED is...
  • Page 33: Chapter 8. Rx Of Distress & General Call

    Chapter 8. RX of Distress & general call 8.1. RX of Distress Alarm (1) Once Distress alarm is received from Distressed vessel, Red color [DISTS] LED is blinking and Alarm sounds. To stop the Alarm, press If the CRS reply to the Distress message, the reply messages appear.
  • Page 34: General Call Rx

    8.2. General call RX (1) In case [Auto ACK] is [on], if you receive individual call & group call, automatically, ACK reply transmits and the frequency is set to TX/RX counter party. (2) Flow Chart RX Individual Call Green [OTHER] LED blinks and alarm sounds. In case [Auto ACK] set is [off], press button and transmit , then the frequency is shifted to voice communication frequency and the voice...
  • Page 35: Chapter 9. How To Use Print

    (3) Usual operation. f) Slide the paper up until it appears in front of Check the main unit of SRG-3150DN is turned on. the platen. If power on, it is able to print TX/RX DSC MESSAGE g) Lower the column indicator bar.
  • Page 36: Chapter 10. How To Use Sd-250(Alarm Box)

    Chapter 10. How to use SD-250(Alarm box) 10.1. Distress transmitting 10.2. In case of receiving distress signal (1) If you press 'Distress key' (Red Button) for 3 (1) Distress LED blinks and sounds 'bip'. sec., it alarms for 3 seconds. Check contents displayed on the screen and press After that, the red light is turned on with bip-sound.
  • Page 37: Chapter 12. Circuit Explain

    Chapter 12. Circuit explain 12.1. Overview of SRG-3150DN SRG-3150DN MF/HF DSC RADIO equipment consists of circuit, PRINTER, ATU (SAT-100). RX ANT TX/RX ANT NBDP SN-100 SRG-3150DN SYSTEM Control circuit MF/HF Transmitting filter Circuit W/K Receiving Circuit SAT-100 Power Amplifier Circuit...
  • Page 38: Control Circuit (T-1110)

    12.2. CONTROL CIRCUIT (T-1110) The Control Circuit consists of MF/HF TX/RX circuit, Local Synthesizer circuit, Power circuit and CPU circuit. (1) MF/HF RX Circuit < RX BLOCK DIAGRAM > RX method is a Double Super-heterodyne receiver in 2'nd MIXER (MX1), it is mixed with 2'nd LOCAL using intermediate frequencies,...
  • Page 39: Local Synthesizer Circuit

    (3) Local Synthesizer Circuit The output of 14MHz OCXO(Over Compensated frequency multiplier circuit and use as 2'nd LOCAL. X-tal Oscillator) is a standard frequency and PLL 3'rd LOCAL (BFO, Beat Frequency Oscillator) makes IC(IC54), VCO(VCO1), DDS(IC56) is output as 1'st 456.4kHz_125Hz signal directly from DDS (IC62).
  • Page 40: Control Circuit

    (5) Control Circuit control part consists CPU(IC30), frequency for SYNTHESIZER or REF/BFO. In EEPROM(IC33,37), REAL TIME CLOCK(IC28), addition, the CPU pass signal (LOCAL CONTROL) to CLOCK Generator(X3), RS-232/422 Data Com- indicate various information (receiving frequency, device, MODEM, Audio amplifier(IC32), receiving mode, band, width) set by operating Amplifier, IC(IC22,IC42,IC46,IC48), LCD Contrast / panel of controller unit and transmit in control unit.
  • Page 41: W/K Receiving Circuit (T-1112)

    12.4. W/K Receiving Circuit (T-1112) RX method is a Double Super-heterodyne receiver PASS FILTER. as such MF/HF receiving method and The signal is mixed with 1'st local frequency (W/K 1'st intermediate frequency is 49.455MHz and 1'st LO) supplied from inner SYNTHESIZER and 2'nd is 455 KHz.
  • Page 42: Function Diagram Of Rear Side

    12.7. Function Diagram of Rear Side ① ANT ⑦ PRT or D/L(9) : : IMPEDANCE 50Ω MF/HF TX/RX. ANT. JACK PRINTER (OKI / DPU-414) connector or PROGRAM Down Load connector ② W/K : IMPEDANCE 50Ω W/K RX. ANT. JACK ⑧ REMOTE(9) : REMOTE INTERFACE connector ③...
  • Page 43: Chapter 13. Nbdp Terminal

    Chapter 13. NBDP Terminal 13.1. NBDP Terminal Main Unit ①. FRONT PANEL (LCD): CHANNEL, TX/RX FREQUENCY, RF.GAIN, CLARIFY; ATT, AGC, and FUNCTION KEYS are displayed. ②. SPEAKER : Alarm rings when it receives data or warning signal. ③. TX LED : Red light on TX LED ④.
  • Page 44: Control Function In Keyboard

    7. [NBDP Test] : Transmitting signals of Dot, Mark, Space. Use for testing printer and NBDP TX/RX condition. 8. [LCD-off (F12) : The function of LCD off and in the case that LCD is off, if any button is pressed, LCD is on. (3) Control function in Keyboard [PgUp] : Adjust channel to next channel.
  • Page 45: Connecting Specific Station

    (2) Connecting specific station a) Call the menu pressing [F10] to call SUB MENU key. [Ref.] ☞ to stop calling, press [F8] and it will be back to Telex initial screen. f) If connected, cursor blinks on the left top of the screen.
  • Page 46: Transmitting File

    (4) Transmitting file b) Move the cursor to 2. [FEC] with [ ]/[ ] After performing ‘(1)’ or ‘(2)’, operate the unit as button Press [Enter] and the following screen below order. shows. a) Press Function button [F4] Move the cursor to the file you want using [ ]/[ ] button Press [Enter] button and the file will be transmitted...
  • Page 47: Connecting With The Other Station By Collective Fec Mode

    (2) Connecting with the other station by (3) Communication in FEC mode collective FEC mode. After performing ‘(1)’ or ‘(2)’ above, operate the a) Press [F10] button on the keyboard and Main unit as following order. Menu screen shows. a) When the telex is connected with counter party in FEC mode, initial screen of [CFEC] Mode shows and the communication starts on this condition...
  • Page 48: Transmitting File

    (5) Transmitting file b) Move the cursor to 2. Station Edit with After done above (1) of (2), follow the operation [ ]/[ ] button Press [Enter] and the following as below. screen shows. a) Press [F4] and below screen is displayed. Revert other station...
  • Page 49: Station Print (Counter Party & Frequency Print)

    13.7. Station print (Counter b)Move the cursor to 4. Macro Command with [ ]/[ ] button Press [Enter] and the following party & Frequency print) screen shows. a) Press [F10] button on the keyboard and Main Menu screen shows. c) Move the cursor & select the command no. with [ ],[ ],[ ],[ ] button [Enter] b) Move the cursor to 3.
  • Page 50: Initial Setting Of System Set

    c) Message can be written and revised. Also FEC, (1) Setting of [0. ARQ/FEC 4~ or 5~digit ID] NAVTEX, Received DATA is saved here. After ‘(b)’ select [0. ARQ/FEC 4- or 5-digit ID] [Ref.] ☞ The Function can be used to make [Enter] Input the ID with [Number] button message using [function key] on the botton of...
  • Page 51: Selecting Of [5. Navtex Station Selection]

    (6) Selecting of [5. NAVTEX Station Selection] (10) [9. Etc. Setting] set up ① Function to select NAVTEX station RX. Select the ① After ‘(2)’ select [9. Etc Setting] character from A to Z with [ ]/[ ] button and you press [Enter] and the following screen will show.
  • Page 52: Nbdp Test

    13.11. NBDP test ⑦ 6. Freq-Shift View a) Press [F10] button on the keyboard and : After Freq-Shift Correct, Main Menu screen shows. this shows how well the frequency compensation is done. [Ref.] ☞ press [Enter] button or [ESC] button and it will be back to NBDP Test Menu screen.
  • Page 53: Chapter 14. Nbdp Terminal Circuit

    MARK (1.7kHz-85Hz) and SPACE (1.7 kHz + 80 Hz) SUPPLY. signals are generated. There is power input, SRG-3150DN connector, ② One side is delivered to SRG-3150DN through W/K receiving connector, TX AND RX cable connector, EARTH Plate, keyboard connector, EMC attenuator and matching tool.
  • Page 54: Chapter 15. Troubleshooting

    150W~500W b) Check T-1110(SRG-3150DN) PCB and T- (4) 100MHz band max 150W, dummy load of 50Ω 1113(SRG-3150DN) PCB, if this part is not good, (5) Frequency counter that can be check 100MHz have to change. band c) Not able to receive from unmatched channel (6) OSCILLOSCOPE that can be check 100MHz band and error sign is displayed.
  • Page 55 Check that 1.7 kHz ±85Hz on the 11th of DM1 of power supply is connected toSRG-3150DN. And, if T-130 PCB there is error, check the power supply switch, the Check that the signal is supplied to SRG-3150DN connector cable to SRG-3150DN, fuse (5A), power polarity. 15.5.
  • Page 56 Chapter 16. Circuit Diagram & External Diagram...

Table of Contents