Crown CSHB60-90ABP Installation, Operation And Service Manual

Oil-fired central furnace

Advertisement

Quick Links

OIL-FIRED CENTRAL FURNACE
Installation, Operation, and Service Manual
CSHB60-90ABP
• Do NOT store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
• Improper
maintenance can cause a fire or explosion resulting in property
damage, personal injury, or loss of life. For assistance or additional
information consult a qualified installer or service agency.
These instructions should be:
• read prior to installing the furnace
• retained for reference by qualified service personnel
• reviewed before performing any service or maintenance
MO-527
ECN 5412-MA 150729
With Users Information Section
Models:
c WARNING:
installation,
adjustment,
Crown Boiler Company
3633 "I" Street
Philadelphia, Pennsylvania 19134
CSHB60-90ABT
alteration,
service,
MADE IN USA
or

Advertisement

Table of Contents
loading

Summary of Contents for Crown CSHB60-90ABP

  • Page 1 These instructions should be: • read prior to installing the furnace • retained for reference by qualified service personnel • reviewed before performing any service or maintenance Crown Boiler Company 3633 “I” Street Philadelphia, Pennsylvania 19134 MO-527 ECN 5412-MA 150729...
  • Page 2: Safety Section

    See Page 9. cWARNING: Crown oil furnaces are designed to burn No. 1 or No. 2 distillate fuel oil. NEVER USE GASOLINE OR A MIXTURE OF OIL AND GASOLINE. See Page 9.
  • Page 3: Table Of Contents

    All installations and services must be performed by qualified service personnel. TABLE OF CONTENTS SECTION BEGINNING PAGE I. SAFETY SECTION II. GENERAL INSTRUCTIONS A. VENTING B. DRAFT REGULATORS C. DUCT WORK/AIR CONDITIONING D. FILTERS MOUNTED EXTERNAL TO FURNACE E. LIMIT POSITION AND LOCATION F.
  • Page 4: General Instructions

    All installations and services must be performed by qualified service personnel. II. GENERAL INSTRUCTIONS - READ BEFORE START OF INSTALLATION 1. The heating output capacity of the furnace proposed for installation should be based on a heat loss calculation made according to the manuals provided by the Air Conditioning Contractors of America (ACCA) or the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc.
  • Page 5: Venting

    The CSHB60-90 may be vented through a standard correctly sized chimney. The CSHB60-90 may also be horizontally vented through a side wall. Crown has available the Field model FDVS- 45/FVOP-415 side wall vent kit for such applications. When installing the FDVS-45/FVOP-415 side wall vent kit, outside combustion air must also be applied to the burner.
  • Page 6 All installations and services must be performed by qualified service personnel. SIDE WALL VENTING APPLICATION ORDER INFORMATION FIELD VENT COMBUSTION AIR TERMINATION KIT INTAKE KIT (15’ application MAX) (FOR COMBUSTION AIR APPLICATIONS ONLY) BURNER PART NUMBER PART NUMBER Beckett AFG 160930 160945 The Field vent kit is set up with 4 inch diameter vent pipe with concentric through-the-wall vent termination/inlet air...
  • Page 7: Draft Regulators

    All installations and services must be performed by qualified service personnel. B. DRAFT REGULATORS: A draft regulator is supplied with the furnace and should be installed according to the regulator manufacturers recommendations. With the burner operating, use a draft gauge to adjust the regulator to the proper setting. (refer to the instructions enclosed with draft regulator to adjust to the proper setting).
  • Page 8: Limit Position And Location

    (See Fig. 2). E. LIMIT POSITION AND LOCATION cWARNING: The predetermined limit location on this Crown oil fired furnace has been tested and approved by Thermo Products, LLC. Any attempt to relocate this safety control or replace this safety control with a control that is not approved, or is incompatible, may result in personal injury, substantial property damage or death.
  • Page 9: Burner Installation

    All installations and services must be performed by qualified service personnel. F. BURNER INSTALLATION: NOTICE: Remove all cardboard packing from around chamber before installing burner. The oil burner will mount on three stud mounting bolts on the lower mounting plate covering the opening in the front of the heat exchanger.
  • Page 10: Burner Specifications And Applications

    AN 80° SPRAY ANGLE AND A HOLLOW SPRAY PATTERN WOULD BE ABBREVIATED IN THE °A TABLE AS “0.65 X 80 ”. For more specific burner information, contact Crown Boiler Co, P.O. Box 14818 3633 I St.. Philadelphia, PA 19134 INPUT CAPACITY SELECTION CHART EQUIVALENT EFFECTIVE...
  • Page 11: Heat Exchanger Cleaning Instructions

    All installations and services must be performed by qualified service personnel. H. HEAT EXCHANGER CLEANING INSTRUCTIONS: c WARNING: THE HEAT EXCHANGER MUST BE CLEANED BY A QUALIFIED SERVICE PERSON. It is important to inspect and clean the heat exchanger once a year, or as necessary, to remove any build-up of soot. A layer of soot on the inside of the heat exchanger will act as an insulator and reduce heat transfer, resulting in less efficiency.
  • Page 12: Users Information Section

    WARNING: NEVER burn garbage or refuse in your furnace. Never try to ignite oil by tossing burning papers or other material into your furnace. c WARNING: Crown oil furnaces are designed to burn No. 1 or No. 2 distillate fuel oil. NEVER USE GASOLINE OR A MIXTURE OF OIL AND GASOLINE.
  • Page 13: Filter Cleaning And Locations

    All installations and services must be performed by qualified service personnel. E. FILTER CLEANING AND LOCATION: The air filters should be inspected each month and cleaned when dirty. Cleaning the air filters frequently may reduce airborne contaminants from entering the furnace and depositing in the furnace, duct system and home. c WARNING: To avoid injury from moving parts, hot surfaces, or electrical shock, shut off the power to the furnace before removing any furnace access doors to service the air filters.
  • Page 14: Appendix-A Replacement Parts List

    All installations and services must be performed by qualified service personnel. APPENDIX-A Replacement Parts List...
  • Page 15 All installations and services must be performed by qualified service personnel.
  • Page 16: Appendix-B Wiring Diagrams

    All installations and services must be performed by qualified service personnel. APPENDIX-B Wiring Diagrams CSHB60-90ABP BLOWER SPEED TAPS COOL = A/C Tap HEAT = Heating Tap LOW = Constant air or Dehumifier...
  • Page 17 All installations and services must be performed by qualified service personnel. CSHB60-90ABT...