7. Service Mode

7.1. Service Autotest
1. Set PR to program 3 (Colours) and press SW2 (T°C)
3. Bring PR to desired test step (1
LCD Display status:
I2 Door Lock Symbol -> Fixed on
SS3 -> SAU
The test steps are as below ;
Step 1:
Selector Program 1 (Cotton) will be "HEATER ON"
Before heating it should take water till first level frequency then
start heating.
Heater will be on max. 8 minutes after this 8 minutes if the temp.
doesn't change more than 2°C then it will give NTC failure.
(E05).
Or if the NTC connection is broken then it should give again E05
NTC failure.
At the end of heating, "SAU" visualization should make slow
blink to indicate that the step is over.
Note: If user changes the selector position, machine will do what
is defined for the new selected position.
Step 2:
Selector Program 2 (Cotton Prewash) will be "PUMP ON"
Temperature will be measured, if it is higher than 50 °C, it should
take 60 sec. cooling water, and then make "Drain + 5 sec."
At the end of pump activation, "SAU" visualization should make
slow blink to indicate that the step is over.
st
rd
,2nd or 3
program position) as soon as "SAU" is displayed on LCD.
Step1
PR Position:
Program 1
(Cotton)
Result
HEATER ON
When entering in
Comments :
service test, door
will be locked.
2. While pressing the SW2, change PR position from third to
second, and release the SW2 button.
Step 2
PR Position:
PR Position:
Program 2
Program 3
(Cotton Prewash)
Result
TEST PROGRAM
PUMP ON
ON (Rapid 12')
Test is over
Door will be
unlocked, machine
will go to END state.
Step 3:
Selector position 3 (Colours) will be a 12 mins test program where all
functions of the appliance will be checked.
Machine will make exactly the same algorithm of Super Rapid 12'.
So, time for selector position 3 is 12 minutes.
At the end of test program "End" is visualized on LCD and door is
unlocked.
12
Step 3
(Colours)
Result

Advertisement

Table of Contents
loading

This manual is also suitable for:

Na-147vc6wgnNa-147vc6wnrNa-147vc6wfr

Table of Contents