  • Page 2: Chapter 1 Introduction

    Chapter 1 Introduction 1.1 System Introduction The product is a voice GSM home / commercial burglar alarm system, combined with advanced GSM digital signal processing technology and GSM wireless mobile intelligent control function. It is highly integrated with digital voice, wireless coding, remote control of home appliances, SMS recognition and other technologies.
  • Page 3  ■A group of wired alarm signal linkage, users can customize the output mode to remote control them. ■Users can remote control 5 smart sockets via phone calls or SMS. ■Wireless accessories adding & fast and easy code matching, the host is compatible with 1527 and millions of groups coding.
  • Page 4: Installation

    2.4 Emergency When an emergency occurs, press the emergency key on the remote control to make the host alarm. Disarm Emergency Stay Home 2.5 Installation The host should be installed in the center of the monitoring area to achieve the best receiving signal range of all wireless detectors. Avoid installing the host near large metal objects, household appliances with high frequency interference, barriers such as reinforced concrete walls and fire doors.
  • Page 5 Host back view: Host side view: Siren Power supply Light bulb Arm/Disarm Transmit 220V AC Wired Infrared sensor Wired door sensor 2.6 Prompt Prompt Explanation Function Key pressing prompt/adding same remote "Beep" once controls or detectors again/quit the adding state "Beep"...
  • Page 6: Chapter 3 System Settings

    Chapter 3 System Settings 3.1 First Power On According to the installation method, insert SIM card into SIM card slot on the back of the host. Then plug the adapter output into the power hole or long press【 】on the side of the host. The host will appear voice prompt "Welcome";...
  • Page 7: Add Detectors

    3.5 Add Detectors Short press【 】,indicator lights of six zones will stay lit to prompt that the host enters remote control adding state. Press【 】again, the indicator light of zone 1 will be lit to prompt that the host enters the adding state of zone 1. Then trigger detectors, if the host beeps twice with the voice prompt "add successfully", the detector has been added into zone 1 successfully;...
  • Page 8: Program Siren

    3.7 Program Wireless Strobe Siren, Smart Socket and Alarm Linkage Switch Short press【 】to enter signal transmitting state. Short press【 】to transmit signals, and short press【 】to quit the state. When the host is in signal transmitting state, there are 7 kinds of signal can be selected: Wireless strobe siren signal Zone 0 Smart socket signal...
  • Page 9 Corresponding reaction of the siren to the host: Host Siren Alarm Alarm Beep once Beep twice Disarm 3.7.2 Program Smart Socket 1. Long press the smart socket for 5 seconds 2. Short press 【 】on the host. All lights will be on at the same time with voiceprompt "0", showing signal 0 is in control.
  • Page 10 3.8 Command List for Remote Setting by Phone Remote setting by phone is available. For example, changing the voice alarm number of the first group to 13899998888 by method below: 1. Call the host's number. 2. Enter the system password (factory default is 123456). 3.
  • Page 11 5. Set a CID number When an alarm occurs, the host will dial the CID number first and upload the alarm zone information to the center alarm receiver, which is compatible with Contact ID communication Steps: protocol. 【9】+【4-5】+【number】 Example:set 075588556688 as the first group of +【#】...
  • Page 12 12. Switch on/off alarm linkage "1" means the relay is linked to alarm while "0" means not. Factory default is 1. Example:,switch alarm linkage off. Steps: Method:Call, enter remote setting status, then 【11】+【0/1】+【#】 input "110#". 13. Switch on/off SMS reply When sending SMS to set, the host can reply to display settings.
  • Page 13 18. Set ringing times for remote System default is 1, 00 means closed remote control control by calling. Example:Set the ringing time to 3 times. Method:Call, enter remote setting status, then Steps: input " 1803#" 【18】+【00-20】+【#】 19. Set zone event codes of The 6 zones will have a events codes to connect alarm center with alarm center.
  • Page 14 25. On/Off AC power cut alarm 0 for turn off voice prompt, 1 for only SMS alert the AC power off, 2 for dial phone number, 3 for dial and siren on.4 for dial and turn on 8th smart socket, 5 for dial, siren on, turn on 8th smart socket.
  • Page 15: Sms Command

    32. Set the external siren alarm 00 for no siren, 99 for maximum siren sound, volume default is 99 Example: set the siren sound to 99 Method: Call, enter remote setting status, then Steps: input "6399#" 【63】+【00-99】+【#】 33. Wired zone alarm setting 03-06 zones are wired zones, their factory defaulted alarm setting is NO.
  • Page 16 Suppose password is 123456, then what alarm host gets or replies is as below: SMS content What Alarm host replies Edit system password+? or ?? to host to get help info For example:123456? password before command For example:1234560 0 Disarm 1 Arm 2 Stay 3 Call back...
  • Page 17 123456 system time 123456 system time Forward - 1234564 2017-12-25 09:00:00 2017-12-01 10:00:00 edit 123456system 123456 system 1234565 Forward - password:654321 password:123456 edit 123456 Delay 123456 delay setting setting Forward - Delay Arm:000 edit Delay arm:030s(0- second(0-255) 255) 1234566 If SMS Delay alarm:000 Delay reply...
  • Page 18: Download And Installation

    Note:Above "123456" is system password. After password is reset, please use new password as Chapter 4 APP The control host can operate remotely by APP. For IOS, it will jump into SMS interface while operation. However, Android system will not jump but will send SMS under backstage.
  • Page 19: Operation

    4.3 Operation After adding account, account name will be showed in home page. Click account name and enter function page, which can set alarm host info. For IOS, click send button on app, it will jump into SMS page to operate, but for Android, it will send SMS but backstage.
  • Page 20: Remote Control Via Phone

    5.2 Remote Control via Phone User can use cellphone or mobile phone to remotely control alarm host directly by dialing the number of the SIM card in the host. Once you hear prompt voice "please input password "(Default password is 123456, user name is 000000.
  • Page 21: Chapter 7 Technical Parameters

    3.Intelligent Zone:It won't alarm when detector in the zone is triggered once. However, it will alarm when its triggered again in 30s after its first trigger. 4.Emergency Zone:No matter its armed or disarmed, alarm host will alarm as long as detectors are triggered. Normally its used for smoke detector and also panic button.
  • Page 22: Chapter 8 Troubleshooting

    Chapter 8 Troubleshooting Troubles Reasons Way to solve Telephone alarm 1.Not set arm 1.Set arm failure 2.Not set alarm number 2.Set again followed by manual 3.Improper assembly, long 3.Adjust component places distance 4.Recode 4.Code mismatching Host can't read 1. No SIM card 1.