Ensure the silicon is sitting parallel on
the hole below it. Hold at eye level
to check the position is correct
Ensuring that the AQUAvalve floods
and drains correctly
Making sure your AQUAvalve floods and
1
drains correctly is simply achieved and
only takes a few seconds.
Hold the AQUAvalve at eye level so that
2
you can see the silicon fitted to the top float
resting on the hole below it.
3
The silicon must create a tight seal when
touching the hole.
If it looks like it is not sitting parallel on the
4
hole below, simply lift the top float and
apply pressure to one side of the silicon,
drop the float and hold at eye level again.
Repeat the procedure if necessary.
info@autopot-usa.com I www.autopot-usa.com I +(1) 702 338 0373
Simple care
guidelines

Care and maintenance

At the end of your growing season, clean
1
the AQUAvalve using warm soapy water.
Using an old tooth brush will help.
The AQUAvalve is easily disassembled.
The top float will slide all the way across
and the bottom float is unclipped from its
pivoting position. The circular discs fitted to
the top float can also be removed by using
pliers to grip the raised point.
At this point is it advisable to remove the
silicones to avoid them being lost.
It is also handy to have a paper clip or
2
pipe cleaner to hand so that you can push
it through the AQUAvalve nozzle, this will
remove any lime scale build up that may
have occurred during the growing season.
Blowing through the AQUAvalve nozzle will
also help to remove any build up. Do not
under any circumstances use a drill & drill
bit to clear the AQUAvalve nozzle.
This
will
potentially
damage
the
AQUAvalve beyond repair.
Your Auto8
Set-up Guidelines
info@autopot-usa.com I www.autopot-usa.com I +(1) 702 338 0373
8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Auto8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Autopot Auto8

  • Page 1 Do not under any circumstances use a drill & drill bit to clear the AQUAvalve nozzle. This will potentially damage AQUAvalve beyond repair. info@autopot-usa.com I www.autopot-usa.com I +(1) 702 338 0373 info@autopot-usa.com I www.autopot-usa.com I +(1) 702 338 0373...
  • Page 2 FlexiTank and FlexiTank Pro are the only collapsible reservoirs Thread ¼" pipe into the Rescrew collar - DON’T that AutoPot recommend for use with Auto8 Tray Systems. tray through the grommet. overturn... when you A minimum 25gal reservoir is required per unit.

This manual is also suitable for:

Auto82.2galAuto83.9gal

Table of Contents