BPA10T30W100 Broadband System User Manual User Manual - BPA10T30W100 - Please read this manual before using the equipment. And keep this manual with the equipment. E-Mail: sales@l2microwave.com www.l2microwave.com - 1 -...
BPA10T30W100 Broadband System User Manual - Contents - GENERAL ..........................4 1.1. Information about this User Manual ........................4 1.2. Purpose of Operation ............................4 1.3. Responsibility of the Operator ..........................5 1.4. Specifications ................................ 6 SAFETY ..........................8 2.1.
Page 3
BPA10T30W100 Broadband System User Manual 4.3.2. LAN Control ................................. 19 E-Mail: sales@l2microwave.com www.l2microwave.com - 3 -...
1.2. Purpose of Operation • The BPA10T30W100 is used to amplify electrical input signals with frequencies and powers that meet the limits specified in the technical specifications. • All interfaces are used to connect external devices, the inputs and outputs of which correspond to the requirements of the respective interface specifications provided in the technical specifications, please refer to the data sheet of the BPA10T30W100.
BPA10T30W100 Broadband System User Manual • RF amplifiers that produce high field strength through radiation antennas for EMC measurements, materials, and device testing in fully shielded chambers. • RF amplifier for energy generation for particle acceleration. • RF amplifiers for feeding magnetic field coils.
BPA10T30W100 Broadband System User Manual 1.4. Specifications ELECTRICAL SPECIFICATIONS @ 220VAC, 25C, 50 Parameter Symbol Unit Operating Frequency 1000 3000 Output Power @ P , CW Watt Power Gain @ Psat Input Power for Rated P G Gain Flatness @ Rated P ±1.5...
Page 7
BPA10T30W100 Broadband System User Manual OPTIONS Auto Gain Control Remote control Display Option # 2 color LED Option #000 2 color LED Option #100 Touch LCD Option #101 2 color LED Option #110 Touch LCD Option #111 Description -. Control function to improve linearity ;...
2.1. Basic Safety Instructions Chapter 1 "General" of this manual contains "Basic Safety Instructions" that apply to all products produced and supplied by L2 Microwave. The BPA10T30W100 broadband amplifier system and its ancillary equipment must only be operated by qualified technicians.
2.2.7. Occupational safety from RF shielding The BPA10T30W100 broadband amplifier system is shielded from all RF cables, shielding covers and case components to ensure that they are not exposed to RF radiation even if they are close together for extended periods of time.
BPA10T30W100 Broadband System User Manual • Use personal protective equipment in the event of smoke formation. Use breathing protection in the danger zone that is independent of the ambient air. 2.2.9. Rules for amplifier services Do not operate the amplifier system (equipment) unless the case is closed.
Therefore, we recommend installation in a spacious space with no dust or other contaminants. Others The operator of the BPA10T30W100 should not be disturbed during operation of the broadband amplifier system. The recommended power of the BPA10T30W100 is 1.6kW or more.
Page 12
The minimum required VSWR for the antenna should be used under 1.5 : If the operator wants to use it under high VSWR conditions, the amplifier's output can be used at a lower level. The following table shows VSWR condition of Load vs. Output Power of BPA10T30W100. Output power...
BPA10T30W100 Broadband System User Manual 4. Operation method This chapter describes the operation and condition of the amplifier. The AMP ON / OFF button on the front panel operates the amplifier and checks the condition of the amplifier. If an error occurs in the amplifier, the Alarm LED on the front panel will change to RED and the amplifier will go off.
BPA10T30W100 Broadband System User Manual 4.2. Alarm and Description for Status LCD This Chapter describes the front status of LCD. 4.2.1. Initial Screen Status • Description of Display part User can change the FWD and RVS values of the RF Power Display by selecting dBm or Watt of the display.
Page 15
BPA10T30W100 Broadband System User Manual • Description of AMP Status part - This part displays the status of AMP inside the shelf. - You can change the status by pushing the button of Amp ON / OFF. Amp OFF normally.
Page 16
BPA10T30W100 Broadband System User Manual • Description of RF Power Display part - Display RF Power status and change the % of color by output. (Rated output is 100%.) - Display FWD (Forward Detect) Power value. - Display RVS (Reverse Detect) Power value.
Page 17
BPA10T30W100 Broadband System User Manual - It is occurred if FWD value is higher than RVS value. - Check the equipment connected to the RF Out Pin such as cables, antennas and so on. -> You have to use the shelf after checking RF Out Pin.
BPA10T30W100 Broadband System User Manual 4.3. Remote Control 4.3.1. GPIB Control • Description of GPIB part ① Change or display the address of GPIB. - ▲ : The GPIB address value is increased. - ▼ : The GPIB address value is decreased.
Page 19
BPA10T30W100 Broadband System User Manual 4.3.2. LAN Control • IP Address Set To connect to the LAN, User has to check the user’s network IP Address and be entered network IP address into the amplifier system. In order to input IP Address to the amplifier system, it must be entered on the LCD window and the LCD GUI program at the same time.
Page 20
BPA10T30W100 Broadband System User Manual When you are done, close all folders. 5. Close the “Control Panel folder” of window and record the IP Address entered in the “'Remote_NDIS Host' Settings” folder in the IP address of the LAN box.