Download Print this page

SoundCraft Secura Key Radio Key 600 Operating & Installation Manual page 16

Stand alone proximity access control system with dynascan technology

Advertisement

Radio Key
600
®
ACCESS CONTROL UNIT
P1/J1
]
9-14 VDC +
POWER
GND
]
COM
LATCH
NC
RELAY
NO
]
NC
SHUNT
NO
RELAY
COM
_
]
REX
+
INPUT
CPU
COIL 1
ANTENNA
COIL 2
LED RED
LED GRN
BEEPER
VCC
P2/J2
SOLID LINE FOR ELECTRIC STRIKE OR OTHER FAIL
1
MAGNETIC LOCK OR OTHER FAIL
USE SHIELDED CABLE FOR
,
2
UNSHIELDED
NON
(
"
SUCH AS
ZIP CORD
3
USE UNSHIELDED CABLE
N
:
OTE
IF COMMON POWER SUPPLY IS USED FOR BOTH THE RK
4
SURE TO INSTALL THE DIODE WHICH IS PROVIDED WITH THE ACCESS CONTROL UNIT
All manuals and user guides at all-guides.com
3
RED
1
BLACK
2
GREEN
3
BLUE
4
YELLOW
5
BLUE
6
YELLOW
7
GREEN
8
BROWN
9
ORANGE
10
3
N/O EXIT
PUSH BUTTON
TO EXTERNAL
ALARM SYSTEM
N/C MAGNETIC
DOOR CONTACTS
SHIELD
Connect to P1, black wire (GND)
WHITE
1
BLUE
2
ORANGE
3
GREEN
4
YELLOW
5
RED
6
-
SAFE LOCKING DEVICE
J2,
3 - 6,
PINS
AND
-
TWISTED SEPARATE CABLE FOR PINS
",
LAMP COARD OR SPEAKER WIRE
18-22AWG
FOR PINS
Figure 3 - Wiring Diagram
Secura Key Ÿ 12
Operating & Installation
1
/
BLACK
NOT USED
/
BLACK
/
BLACK
2
AUXILIARY READER
-
;
SECURE LOCKING DEVICE
.
1 & 2
)
1-10
600
AND ELECTRONIC DOOR LOCK
4
9-14
VDC
+
POWER
-
SUPPLY
MAGNETIC
LOCK
DOOR
STRIKE
STRIKE OR
MAGNETIC
LOCK POWER
SUPPLY
4
J1
OPTIONAL
DASHED LINE FOR
,
BE
.

Advertisement

loading