Bio Smart Technologies KF-25GW Owner's Manual

Bio Smart Technologies KF-25GW Owner's Manual

Mini-split commercial 9,000 - 12,000 - 18,000 btu air conditioner

Advertisement

TM
B
for a green, healthy environment
9,000 - 12,000 - 18,000 BTU
OWNER'S MANUAL
OWNER'S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your unit and retain it for future reference.
Please read this manual carefully before operating
TYPE : WALL MOUNTED
your set and retain it for future reference.
TYPE : WALL MOUNTED
.
S
I O
M A R T
Mini-Split Commercial
Air Conditioner
.
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KF-25GW and is the answer not in the manual?

Questions and answers

Summary of Contents for Bio Smart Technologies KF-25GW

  • Page 1 M A R T ® for a green, healthy environment Mini-Split Commercial 9,000 - 12,000 - 18,000 BTU Air Conditioner OWNER’S MANUAL OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your unit and retain it for future reference. Please read this manual carefully before operating TYPE : WALL MOUNTED your set and retain it for future reference.
  • Page 2: Table Of Contents

    Contents Safety Precautions Electrical Safety Indoor and Outdoor Unit’s Outline Operating Instructions Installation Preparation Installation Fixture of Indoor Unit Installation Fixture of Outdoor Unit Gas Leakage Inspection Is the Installation Proper? Mainenance and Service Troubleshooting Specification...
  • Page 3: Safety Precautions

    Safety Precautions Page 1 Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. • Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
  • Page 4 Safety Precautions Page 2 Indoor/outdoor wiring connections must Safely dispose off the packing materials. Make sure to check that the power cable be secured tightly and the cable should Like screws, nails, batteries, broken plug is not dirty, loose or broken and be routed properly so that there is no things etc after installation or svc and then only insert the plug completely.
  • Page 5 Safety Precautions Page 3 Do not use the product for special purposes, Do not block the inlet or outlet of air flow. Use a soft cloth to clean. Do not use such as preserving foods, works of art, etc. It harsh detergents, solvents or splashing is a consumer air conditioner, not a precision water etc .
  • Page 6: Electrical Safety

    Safety Precautions Page 4 Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet. • Do not cut or remove the grounding prong from the power plug. •...
  • Page 7: Indoor And Outdoor Unit's Outline

    Product Introduction Page 5 Indoor and Outdoor Unit’s Outline INDOOR AND OUTDOOR UNIT 'S OUTLINE Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type. Indoor Units Air inlet Plasma filter Air filter ON/OFF button...
  • Page 8: Operating Instructions

    Product Instructions Page 6 Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
  • Page 9 Page 7 Wireless Remote Cont r oller The controls will look like the following. ON-OFF BUTTON Used to turn off/on the unit. 2. MODE BUTTON AUTO HI MID LO Used to select the operation mode. CONT 3. ROOM TEMPERATURE SETTING BUTTONS HOUR START Used to select the room temperature.
  • Page 10: Installation Preparation

    Installation Guide Page 8 Installation Preparation Installation Preparation Customer/Warranty Service: 800-595-9605...
  • Page 11 Installation Guide Page 9 Installation Preparation Installation Preparation ©2020 BioSmart Technologies...
  • Page 12: Installation Fixture Of Indoor Unit

    Installation Guide Page 10 Installation Fixture of Indoor Unit Installation Fixture of Indoor Unit Customer/Warranty Service: 800-595-9605...
  • Page 13 Installation Guide Page 11 Installation Fixture of Indoor Unit Installation Fixture of Indoor Unit ©2020 BioSmart Technologies...
  • Page 14: Installation Fixture Of Outdoor Unit

    Installation Guide Page 12 Installation Fixture of Outdoor Unit Installation Fixture Of Outdoor Unit Customer/Warranty Service: 800-595-9605...
  • Page 15: Gas Leakage Inspection

    Installation Guide Page 13 Gas Leakage Inspection Gas Leackage Inspection ©2020 BioSmart Technologies...
  • Page 16: Is The Installation Proper

    Installation Guide Page 14 Is the Installation Proper? Is The Installation Proper ? Customer/Warranty Service: 800-595-9605...
  • Page 17 Installation Guide Page 15 Is the Installation Proper? Is The Installation Proper ? ©2020 BioSmart Technologies...
  • Page 18: Mainenance And Service

    Maintenance and Service Page 16 Mainenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. Indoor Unit Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any of these •...
  • Page 19 Maintenance and Service Page 17 Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.
  • Page 20: Troubleshooting

    Maintenance and Service Page 18 Troubleshooting Troubleshooting Tips! Save time and money! Following symptoms are not air conditioner's troubles The following table shows a series of seeming malfunctions. Please check the following items before calling the Authorized Technical Service. WHAT HAPPENS REASON •...
  • Page 21 Maintenance and Service Page 19 Troubleshooting Troubleshooting Tips! Save time and money! Problems and possible solutions TROUBLESHOOTING The following table shows a series of problems and their possible reasons and solutions. Please carry out the following checks before contacting the Authorized Technical Service. The air conditioner does not operate at all.
  • Page 22 Maintenance and Service Page 20 Troubleshooting Troubleshooting Tips! Save time and money! CAUTION Never try to repair the Air Conditioner by yourself If one of the following malfunctions occur, immediately stop operation, turn off the main switch and contact the Authorized Technical Service: •...
  • Page 23: Specification

    Page 21 Specification MODEL KF(R)-25GW KF(R)-35GW KF(R)-50GW Function Cooling & Heating Voltage, Frequency 220V / 240V, 60Hz Cooling 9,000 12,000 18,000 Capacity(BTU) Heating 9,100 11,600 19,000 Cooling 1,185 1,890 Rated input power(W) Heating 1,320 1,860 Cooling 4.27 8.59 Rated current(A) Heating 4.14 8.45...
  • Page 24 Warranty Registration No. Dealer/Installer Information BioSmart® Mini-Split Systems Green Technology for a Modern World North American Distribution and Sales BioSmart Technologies d, Suite 1 18324 Cook Roa Yelm, Washington 98597 Customer/Warranty Service: 800-595-9605 www.BioSmartSolutions.com...

This manual is also suitable for:

Kfr-25gwKf-35gwKfr-35gwKf-50gwKfr-50gw