Eastern Energy DT-8818 Series Operation Manual

Non-contact infrared thermometers

Advertisement

Quick Links

Non-Contact Infrared Thermometers
DT-8818-DT-8829 series
Operation Manual
Eastern Energy Co., Ltd.
40/4 Vitoondumri Rd., Banbueng
Banbueng, Chonburi, Thailand
1

TABLE OF CONTENTS

INTRODUCTION.............................................
.............................................
................................................
....................................
.............................................
INDICATOR
...................................................
Tel: 66-3844-6117
sale@ete.co.th
www.eastern-energy.com
2
........................
..............................
.....................
........................
...........................
........................
3
3
3
4
4
5
8
8
9
10
11
14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DT-8818 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Eastern Energy DT-8818 Series

  • Page 1: Table Of Contents

    ………………………… DISTANCE & SPOT SIZE ……………………………… SPECIFICATIONS ………………… FRONT PANEL DESCRIPTION ……………………………………… INDICATOR …………………… MEASURMENT OPERATION ……………………… BATTERY REPLACEMENT …………………………………………… NOTES …………………… MAINTENANCE & CLEARING Eastern Energy Co., Ltd. Tel: 66-3844-6117 40/4 Vitoondumri Rd., Banbueng sale@ete.co.th www.eastern-energy.com Banbueng, Chonburi, Thailand...
  • Page 2: Introduction

    INTRODUCTION SAFETY Use extreme caution when the laser beam is turned on.  Thank you for purchase of the 8818/8819/8828/8829 Series IR  Do not let the beam enter your eye, another person’s eye or the Thermometer. The 8818/8819/8828/8829 Series is capable of eye of an animal.
  • Page 3: Specifications

    2. SPECIFICATIONS  Infrared thermometer specifications  General specifications MODEL: 8818 DISPLAY 3-1/2 digit (1999count) LCD with backlighting Range (Automatic selection 0.1 C/ 1 Resolution Accuracy MODEL: 8818 -50.0 C to 550 C/-58.0 Fto 1022 ° ° ° ° -50.0 C to -20.0 TEMPERATURE MODEL: 8819...
  • Page 4: Front Panel Description

    3. FRONT PANEL DESCRIPTION MODEL: 8828 Range (Automatic selection 0.1 C/ 1 C) Resolution Accuracy -50.0 C to -20.0 ± 5 -50.0 C to 200.0 1. IR sensor -20.0 C to 200.0 ± 1.5% of reading ± 2ºC; 2. Laser pointer beam C to 538 ±...
  • Page 5: Measurment Operation

    5. MEASURMENT OPERATION followed by high temperature measurements, some time (several minutes) is required after the low (and before the high) temperature ① Hold the meter by its Handle Grip and point it toward the measurements are made. surface to be measured. This is a result of the cooling process which must take place for the ②...
  • Page 6: Notes

    7. NOTES:  Distance & Spot Size  How it Works As the distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger. Infrared thermometers measure the surface temperature See: Fig: 1. of an object.
  • Page 7: Maintenance & Clearing

    Chromium oxides 0.81 Plaster 0.80 to 0.90 Copper oxides 0.78 Mortar 0.89 to 0.91 Iron oxides 0.78 to 0.82 Brick 0.93 to 0.96 Textiles 0.90 Eastern Energy Co., Ltd. Tel: 66-3844-6117 40/4 Vitoondumri Rd., Banbueng sale@ete.co.th Banbueng, Chonburi, Thailand www.eastern-energy.com...