Do you have a question about the C-G24-NG and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Migali C-G24-NG
Page 1
Gas Countertop Griddles Operating Instructions Before you begin, please read these instructions carefully to use this product correctly, to make the product perform ideally, and to avoid hazards.
Page 2
Models: C-G24-NG(LP) / C-G36-NG(LP) / C-G48-NG(LP) Dear customers and users: Thank you for purchasing our products. In order to be able to better use this product, please read these instructions carefully before any operation, and follow the guide, to avoid any unnecessary trouble during using.
1. Safety Protection Please make sure that the operator is an authorized and licensed technician before you allow him/her to install and operate the products. Be sure to strictly follow this instruction guide during installation and using. The manufacturer is not responsible for any danger or accidents caused by improper operation or maintenance.
Be repaired or changed by unauthorized technicians; Use the spare parts or accessories provided by non- manufacturers; Accidents caused by force majeure; Not strictly comply with related guide of instruction by any reason. 4. Parameter Specifications 4.1:Outline Dimensions(in) C-G24-NG(LP) C-G36-NG(LP)
Page 6
C-G48-NG(LP) 4.2:Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 4”Natural Gas W.C, and 10”L.P. Gas W.C. The external thread of product’s...
intake-tube is 3/4 inches. <Table 1> Intake- burners Total tube Nozzl Model Species pressure B.T.U./ e No. control B.T.U./h (in.W.C.( method Natural 2 pieces 30,000 60,000 C-G24- Independe NG(LP) nt control L.P. Gas 30,000 60,000 Natural 3 pieces 30,000 90,000 C-G36- Independe NG(LP)
Page 8
unpacking; Check the equipment. If it is damaged, please keep wrappers and receipts which must be signed by the carrier representative (Driver), and contact the carriers to pursue a claim within 15 days after receiving; Check all accessories complete. Refer to P15 table 5; Be sure to install supporting legs before using, and do not tear up any label or logo before normal using;...
whether piping joint leaks or not before using, and forbid using an open flame to test! After installing completely, you should check gas supply pressure. Use a pressure gauge which is equipped with liquid (such as U-type pressure gauge, the minimum value is 0.1mbar) or a digital pressure gauge to test.
and flames, and call 911. Safety information can be obtained from your local gas suppliers. When using this equipment, safety precautions should always be followed, including the following: The griddles burners, grates and outside surfaces may become hot after using, so you must be careful to touch; During operation, do not directly touch burners and plates;...
Page 11
Tips: You can use a screwdriver to adjust the height of the flame (Fig.3). 8.2:Igniting the main burner evolve the main fire control valve knob anticlockwise after lighting the pilot light, then the main fire burner is lighted by the pilot light. The power of burner increases as revolving angel increases.
light head, grill and control panel in proper place. Caution: Each main fire nozzle of the burner has been installed before delivery, normal use without adjustment but only switching gas. Adjust only by authorized and licensed technicians. When you change the gas source, you need exchange the corresponding pressure maintaining valve which installed on air intake.
Page 13
Warning: Before cleaning, all control valves must be turned off. Strictly follow the lighting instructions to work again after cleaning! Warning: Wait for the equipment to cool down after the unit has been turned off before you cleaning! Cut off the gas source as not in using; If the equipment is not used for a long time, clean the surface by wiping it with a soft cloth and place it in a well- ventilated area;...
Pull out catch tray from front body until the equipment cools down. Clean grease and other crumbs. Catch tray Reinstall after cleaning. Per use Warning: if the catch tray is permitted fill high, should be cleaned! 10. Troubleshooting <Table 3> Problem Possible causes Problems...
4.Damper opening degree 4.Adjust damper is too large 1.Use the gas of bottom 1.Change gas 2.Not match nozzle diameter 2.Adjust nozzle with gas resources diameter 3.Increase Yellow 3.Not enough air to ignite damper opening flame degree black smoke 4.Turn down 4.In the peak of using valves flow.
Adjustable C-G24-NG(LP)\ 301110001 counter top φ41.5*100 36-NG(LP)\48- steel legs NG(LP) 12. Accessories List <Table 5> C-G24-NG(LP) C-G36-NG(LP) C-G48-NG(LP) Model Name Adjustable 4 pieces 4 pieces 4 pieces steel legs Catch tray 1 piece 1 piece 1 piece pressure maintaining 1 piece...
Page 20
But to update some components and necessary maintenance, can prolong life length of the products. Contact the dealer for assistance. In order to avoid confusion, please follow the format in figure 8 and table 4. Migali Industries, Inc. Trusted Since 1955 516 Lansdowne Ave...
Page 21
Service Call: 800.852.5292 Service Email: warranty@mgiali.com...
Need help?
Do you have a question about the C-G24-NG and is the answer not in the manual?
Questions and answers