SMART is an electronic thermostat for the automatic control of electric towel
radiators. By means of an internal sensor, it is capable of keeping the temperature
of the towel radiator to a desired value.
Ten different electric resistances are available in a range between 100W and
1000W.
Operative modes: Comfort, Standby/Antifreeze and 2hr Boost
with 12 or 24hr Auto Boost.
"Comfort" mode: The thermostat keeps the internal
temperature at the value set by the user.
"Standby/Antifreeze" mode: In this mode, the device is on
standby. However, as soon as the measured temperature falls
below 10°C, the control system activates the heating element, in
order to prevent the internal liquid from freezing.
"Boost" mode: In "Boost" mode, the heating element is
activated for a period of 2 hours independently of the configured
temperature. The temperature is however automatically
controlled in order not to exceed 65°C. At the end of the 2 hours
period, the device returns to "Comfort" mode.
"Auto Boost" mode: The control system enters into "Boost"
mode for 2 hours. After that, it returns to "Comfort" mode for
10, or 22 hours (period configurable by the user) and then it
enters again into "Boost" mode for 2 hours.
This sequence is repeated endlessly.
SMART is compliant with the following standards:
-
Eco-design Directive for Energy-using Products,
2005/32/EC (<0,5W).
-
EN 60335-1:2012
-
EN 61000-3-2:2004
-
EN 50366:2003
-
EN 55014-1:2008
"SMART"
-
EN 60335-2-30:2011
-
EN 61000-3-3:1995
-EN 55014-2:1998
Unit D, Lostock Ind. Est., Lostock Lane, Bolton. Lancashire. BL6 4BL.
Tel. 01204 695387 E-mail
-
EN 60335-2-43:2005
sales@geyser.co.uk
Available colors: - White (RAL 9003).
- Chrome
or aftersales@geyser.co.uk

Advertisement

loading
Need help?

Need help?

Do you have a question about the SMART and is the answer not in the manual?

Questions and answers

Summary of Contents for Geyser SMART

  • Page 1 “SMART” Electronic control for towel radiators SMART is an electronic thermostat for the automatic control of electric towel radiators. By means of an internal sensor, it is capable of keeping the temperature of the towel radiator to a desired value.
  • Page 2: Risk Of Electric Shock

    “SMART” Electronic control for towel radiators WARNING RISK OF ELECTRIC SHOCK! Disconnect power supply before proceeding with installation. Preserve with care the present instruction sheet and read carefully before using the device. •The present device has been designed for exclusive use on a towel radiator.
  • Page 3: Troubleshooting

    “SMART” Electronic control for towel radiators Installation Guide To be used by installer only • Disconnect the device from power supply before proceeding with installation. Protect the device with a 30mA RCD circuit breaker. • Turn the rail upside down and remove the blank from desirable side.
  • Page 4 “SMART” Electronic control for towel radiators User Guide “Comfort Bar”: Indicates the selected Heating element temperature and further accessory information On/Standby button 1/2" GAS thread for fastening on the radiator [+] and [-] buttons: For setting the desired temperature Power cord “Boost”...
  • Page 5 “SMART” Electronic control for towel radiators Press the [On/Standby] button to turn on the device or to enter the “Standby/Antifreeze” mode. NOTE: When the device is switched to "Standby/Antifreeze" mode, it beeps twice for 0.5sec. When the device is switched to “On” mode (i.e. it is turned on), it beeps for 1sec.
  • Page 6 “SMART” Electronic control for towel radiators “Boost” mode: Press the [Boost] button to activate this operative mode. This mode activates the heating element to the maximum power for 2hrs (for safety reasons the maximal temperature is limited to 65°C). To exit the “Boost” mode, press the [Boost] button.
  • Page 7 “SMART” Electronic control for towel radiators Boost/Auto Boost LED functioning summary Blinking red "Boost" mode active. The heating element is powered for 120 minutes (temperature of the radiator automatically limited to 65°C). Blinking "Boost" function active in "24hr Boost” mode. The heating element is...