Safety Precautions ........................11 Handling Precautions • Never connect or disconnect plugs to/from the input/output terminals on the PHA-1 when the external device that drives speakers is powered. Doing so can cause noises and damage the speakers.
+ (plus) side green LED PHA-1. When the ARC-4 Audio Routing output level. illuminates. If it is reversed, Controller is connected to the PHA-1 in the – (minus) side red LED OPTION-2 Input mode, this meter shows the TEST Switch illuminates.
Rear Panel TEST SIGNAL OUT Terminal ANALYZER IN Terminal OPTION-2 Terminal Outputs the test signal used for the Connect the output from the device Used to connect to the ARC-4 with phase measurement. Connect this to which the test signal is fed. the optional cable (RC-7).
NOTE Pulse waveforms are used as the test signal for the PHA-1’s MIC input in order to minimize the influence from ambient noises. If the first edge of the test signal waveform after passing through the device is rising, then it is judged as in phase (+). If falling, then it is out of phase (–).
Or if measuring the phase of the amplifier with speaker, Or if measuring the phase of the amplifier with speaker, increase the distance between the speaker and the PHA-1 or decrease the distance between the speaker and the PHA-1 or lower the amplifier’s volume.
DC9-12V IN DC9-12V IN Turn on the power to the PHA-1 and the device to be measured. Turn the TEST SIGNAL LEVEL knob fully counterclockwise so that Turn on the power to the PHA-1 and the device to be measured.
“Low-Battery,” replace the battery with a new one. If effects unit. the PHA-1 is not used for a long period of time, remove the 4. Slowly turn the TEST SIGNAL LEVEL knob clockwise. The battery and store them separately.
If no level meter’s LED illuminates, device’s output level to lower the confirm whether the connection is signal level fed to the PHA-1. properly done and the power to the subject device is turned on. << Continuous Measurement Mode >>...
Main Specifications / Ratings • Test signal maximum output Level: 660 mVp-p (Repeated Pulse Measurement mode), -23 dBm (Continuous Measurement mode) • Terminals: standard 1/4-inch phone jack x 2 (TEST SIGNAL OUT, ANALYZER IN), 7-pin DIN connector x 1 (for connecting ARC-4: OPTION-2), DC9-12V input jack (for connecting AC adaptor) •...
Turn off the unit and unplug the AC adapter from the outlet and contact your local dealer or Free The Tone for repair in the case of any of the Do not press the switches on the unit with a bare foot, or unexpected following: injury may result.
Page 12
Support/Service Contact the following for support and/or repair service. e-mail address: overseas@freethetone.com...