  • Page 1 Bertec Vision Advantage ® Quick Start Guide...
  • Page 3 Columbus, Ohio 43219 U.S.A. Phone: +1 614 543-8099 Fax: +1 614 430-5425 Information: balanceinfo@bertec.com Sales: balancesales@bertec.com Support: support@bertec.com www.bertecbalance.com Bertec’s authorized representative in the European Community: Emergo Europe Prinsessegracht 20 2514 AP The Hague The Netherlands Bertec Vision Advantage Quick Start Guide...
  • Page 4 A Division of Bertec Corporation Copyright © 2015 Bertec Corporation. All rights reserved. Information in this document is subject to change without notice. Companies, names, and data used in examples herein are fictitious unless otherwise noted. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without express written permission of Bertec Corporation or its licensees.
  • Page 5 The Bertec Vision Advantage Quick Reference Guide is not intended to replace the User Manual and ® should not be used as such. The User Manual should be your primary source of information. Bertec Vision Advantage Quick Start Guide ®...
  • Page 6 Bertec Vision Advantage Quick Start Guide ®...
  • Page 7: Table Of Contents

    Pairing Multiple Head Trackers Note: Additional details for this system can be found in the Vision Advantage User Manual. The user manual is available in the Balance Advantage software by selecting the question mark icon in the top right corner of the screen, and selecting “Help.”...
  • Page 8: Remote Control

    Remote Control Operations Button 1: Button 2: Button 3: Button 4: Left: Right: F12 / Click Portrait: Down Left Right Don’t Know Start/Stop Switch Patient/Clinician Screen Bertec Vision Advantage Quick Start Guide ®...
  • Page 9: Connecting Devices And Starting The Software

    3. Turn on the Head Tracker by sliding the switch on the side towards the LED. You may need to use a small thin object to flip the switch. 4. Run Bertec Balance Advantage from the shortcut on the desktop. To log in, select an operator name, type in the password, and select Login.
  • Page 10: Setting Up An Assessment

    4. Select ‘Load from Existing Test Series’ and select ‘Vision Tracker’. Four assessments should populate the Test Series queue: Baseline Visual Acuity (BLVA), Visual Processing Time (VPT), Gaze Stabilization (GST), and Dynamic Visual Acuity (DVA). Bertec Vision Advantage Quick Start Guide...
  • Page 11 > Select Gaze Stabilization and set the Head Rotation, Starting Side, Metronome settings, and Head Angle. If desired, select Velocity Feedback or Gaze High Performance (more information is given in the Vision Advantage User Manual). > Select Dynamic Visual Acuity and set the correct Head Rotation, Starting Side, Metronome settings, and Head Angle.
  • Page 12: Clinical Instructions

    4. The colored rings in the target area can also be used.The rings are velocity feedback indicators. Black indicates a head velocity that is too slow, white is too fast, and grey is within an acceptable range. > Too Slow Correct Too Fast Bertec Vision Advantage Quick Start Guide ®...
  • Page 13: Charging The Head Tracker

    The minimum recommended charge level needed to perform a full assessment is no less than 25%. > Note: If you charge the Head Tracker from a USB port on the computer, close the Balance Advantage software and make sure the computer stays powered on and plugged in. Bertec Vision Advantage Quick Start Guide ®...
  • Page 14 Bertec Vision Advantage Quick Start Guide ®...
  • Page 15: Led Status Lights

    Not paired not occur when paired and communicating with the Receiver Blue flashing Communicating with Receiver Communicating with Head Tracker Blue solid Unit is on and unpaired Unit is plugged in and unpaired Bertec Vision Advantage Quick Start Guide ®...
  • Page 16: Pairing Head Tracker And Receiver

    3. Once charged, keep the Head Tracker plugged in and switch it to ON. > The LED will continue to blink blue and green. 4. Open the Bertec Balance Advantage software and log in. Notice that the Head Tracker is now blinking blue. >...
  • Page 17 > Turn off the Head Tracker Unplug the Head Tracker and the Receiver from the computer > > Log out of Bertec Balance Advantage Start the pairing procedure over from step 1 > Bertec Vision Advantage Quick Start Guide ®...
  • Page 18: Pairing Multiple Head Trackers

    Once the Head Tracker and Receiver have been paired, keep the second Head Tracker off and plug it in to a separate > computer or wall outlet to charge Each time you switch to a different Head Tracker, repeat the pairing procedure to make sure the system is functioning > normally. Bertec Vision Advantage Quick Start Guide ®...
  • Page 19 Bertec Vision Advantage Quick Start Guide ®...
  • Page 20 Bertec Corporation 2500 Citygate Drive Columbus, Ohio 43219 U.S.A. t + 1 614 543-8099 f + 1 614 430-5425 www.bertecbalance.com We Bring Balance to Lives ®...