SP Scientific FTS SYSTEMS LYO-SEA Operator's Manual

SP Scientific FTS SYSTEMS LYO-SEA Operator's Manual

For virtis genesis

Advertisement

Quick Links

S
E
A
O
'
M
AMPLE
XTRACTOR
SSEMBLY
PERATOR
S
ANUAL
FTS S
L
-SEA
V
T
YSTEMS
YO
FOR
IR
IS
G
ENESIS
S
E
A
AMPLE
XTRACTOR
SSEMBLY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTS SYSTEMS LYO-SEA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SP Scientific FTS SYSTEMS LYO-SEA

  • Page 1 ’ AMPLE XTRACTOR SSEMBLY PERATOR ANUAL FTS S -SEA YSTEMS ENESIS AMPLE XTRACTOR SSEMBLY...
  • Page 3 The information in this document is subject to change without prior notice. Always confirm with SP Scientific that you are using the most current version of this document. SP Scientific is free to modify any of its products and services, in any manner and at any time, notwithstanding the information contained in this document.
  • Page 4: Important Symbols

    Never use acrylic closures if they are cracked or crazed.  Never use with toxic, corrosive, flammable or organic materials unless special precautions are in place to prevent injury to personnel or damage to equipment. Rev 002, 04/11 © SP Scientific 2011...
  • Page 5: Warranty Information

    Please take this opportunity to locate the serial tag on your new FTS Systems Lyo-SEA for VirTis Genesis and record the information below for future reference. SP Scientific also recommends that you complete and return your unit’s warranty registration card.
  • Page 6 Rev 002, 04/11 © SP Scientific 2011...
  • Page 7: Table Of Contents

    Freeze Dryer Safety Warnings ..........................ii Warranty Information ............................iii Introduction ......................... 1 Extractor Components ............................1 Installation ........................3 Standard Door Removal ............................3 Operation ........................5 Operation ................................5 Shelf Spacing ............................... 9 Rev 002, 04/11 © SP Scientific 2011...
  • Page 8 Contents FTS Systems Lyo-SEA for VirTis Genesis Rev 002, 04/11 © SP Scientific 2011...
  • Page 9: Introduction

    Vacuum Gauge Acrylic Door Vacuum Antechamber Stoppering Ram Antechamber Isolation Door Jaw Controls Selector Arm Thumbscrews Inert Gas Backfill / Vacuum Break Vacuum Pump Inlet Filter Isolation Door Lock / Handle Rev 002, 04/11 © SP Scientific 2011...
  • Page 10 Introduction FTS Systems Lyo-SEA for VirTis Genesis Rev 002, 04/11 © SP Scientific 2011...
  • Page 11: Installation

    This is accomplished by tightening the nuts on the hinge. When proper contact is achieved, a dark black surface should be visible between the acrylic door and the chamber gasket surface. Re-install the left side panel. Rev 002, 04/11 © SP Scientific 2011...
  • Page 12 Installation FTS Systems Lyo-SEA for VirTis Genesis Rev 002, 04/11 © SP Scientific 2011...
  • Page 13: Operation

    (unlocked), slide the antechamber door open. Raise handle to unlock door. Antechamber Isolation Door When the antechamber isolation door is fully open, you may lower the handle to lock the isolation door in position. Rev 002, 04/11 © SP Scientific 2011...
  • Page 14 Operation FTS Systems Lyo-SEA for VirTis Genesis Manipulate the selector arm to select and extract vial(s). Push button on selector arm to open jaw. Vials are held securely in spring-loaded jaws. Push the button on the selector arm to open the jaws. Release the button to close the jaws.
  • Page 15 FTS Systems Lyo-SEA for VirTis Genesis Operation Slide the isolation door closed and lower the handle to lock it into position. Plastic Shroud (Stoppering Ram) Isolation Door Handle lowered to lock isolation door into position. Vacuum Break Valve Prior to stoppering the sample, you may backfill the antechamber with an inert gas, such as nitrogen (N ) via the vacuum break valve.
  • Page 16 Operation FTS Systems Lyo-SEA for VirTis Genesis Before the sample can be removed from the antechamber, the antechamber pressure must be returned to atmospheric pressure. If you have connected an inert gas source for backfilling, remove it now. Open the vacuum brake valve to release vacuum from the antechamber.
  • Page 17: Shelf Spacing

    FTS Systems Lyo-SEA for VirTis Genesis Operation Shelf Spacing Certain applications of the Lyo-SEA sample thief may require shelf spacing adjustments. To adjust shelf spacing: Ensure that all shelves are empty before continuing. Press and hold the stoppering switch in the Down position to allow the shelf stack to compress fully.
  • Page 18 Operation FTS Systems Lyo-SEA for VirTis Genesis Rev 002, 04/11 © SP Scientific 2011...
  • Page 20 SP Scientific 815 State Route 208 Gardiner, NY 12525 USA 3538 Main Street Stone Ridge, NY 12484 USA www.SPScientific.com (800) 431-8232 (845) 255-5000...