Abax OBS-243K User Manual page 13

Pure sine wave inverter, modified sine wave inverter
Table of Contents

Advertisement

NOTICE: When connect to the appliances, remember to turn on the inverter before turn
on the appliance.
3-3-3. If the audible alarm be ignored the inverter may be automatically shut down when the
battery voltage drops to 9.8-10.2V / 19.6-20.4V, in order to prevent damage to the battery from
excessive discharge.
3-3-4. If a defective battery charge system has caused the battery voltage to rise to a dangerously
high level, the inverter automatically shut down.
3-3-5. The cooling fan is designed to operate only when the temperature goes up or when the
loads are applied.
CAUTION! Although the inverter incorporates the protection function against over-
voltage, there would be still the possibility of getting the unit damaged, if the input voltage
exceeds 16V/32V.
10