Factory Service Policies ........12 Technical Support ............... 12 General Service Procedures ..........12 Antenna Coupler Interconnect ......13 Environmental Qualification Form ..... 14 DC50 STC Coupler Dimensions ..........18 Avidyne DC50 Datalink Coupler Installation Manual Page ii P/N 600-00082-000 Rev 04...
Page 4
List Of Illustrations Figure 1. Installation Wiring ........13 Figure 2. Top View and Side View ......18 Avidyne DC50 Datalink Coupler Installation Manual Page iii P/N 600-00082-000 Rev 04...
1 General Information 1.1 Introduction This manual contains information about the physical, mechanical and electrical characteristics of the Avidyne DC50 Datalink Coupler, and provides installation instructions for this unit. Follow the installation instructions carefully to obtain maximum performance from the Antenna Coupler.
All installation procedures should follow the acceptable practices, methods, and techniques of avionics installations as described in FAA Advisory Circulars. 2.2 Unpacking and Inspection The shipping carton of the DC50 contains one set of the following components and parts: Part Number Description...
PTT discrete ungrounded could damage the coupler. CAUTION: IF ANY OF THE REQUIREMENTS ABOVE ARE NOT ADHERED TO, THE COUPLER MAY NOT FUNCTION CORRECTLY AND MAY BE DAMAGED. Avidyne DC50 Datalink Coupler Installation Manual Page 4 P/N 600-00082-000 Rev 04...
The coupler does not have an on/off switch. Refer to Appendix A, Datalink Coupler Interconnect. Power, Ground and PTT are all connected through the 9-pin male D shell connector available at the front of the coupler. Avidyne DC50 Datalink Coupler Installation Manual Page 5 P/N 600-00082-000 Rev 04...
2.6 Electrical Load Worksheet 2.6.1 Coupler Electrical Load The Avidyne Coupler has the following power consumption at 28 VDC (700-00015-000): Operating Electrical Load Duty Cycle Mode Transmit 0.110 amps at 28VDC Intermittent Receive 0.055 amps at 28 VDC Continuous The Avidyne Coupler has the following power consumption at 14 VDC...
2.9 Weight and Balance Weight and balance computation is required after the installation of the DC50 Datalink Coupler. Follow the guidelines as established in AC43.13- 1B, Chapter 10, Section 2. Make appropriate entries in the equipment list indicating items added, removed or relocated along with the date accomplished.
4. Connect Pin 8 on connector P1 of the coupler to suitable aircraft ground. 5. Connect Pin 5 on Connector P1 of the coupler to the PTT discrete of the interfacing comm, which may be connected Avidyne DC50 Datalink Coupler Installation Manual Page 9 P/N 600-00082-000 Rev 04...
Page 14
9. Connect the Antenna port of the coupler labeled J1 Antenna (see Appendix A) to the coax from the top mounted VHF/Datalink antenna. 10. Reinstall the VHF comm. Avidyne DC50 Datalink Coupler Installation Manual Page 10 P/N 600-00082-000 Rev 04...
7. Verify operation of the datalink, according to the datalink installation manual. 8. Conduct a radio check by transmitting and receiving via the comm. 9. Re-verify operation of the datalink according to the datalink installation manual. Avidyne DC50 Datalink Coupler Installation Manual Page 11 P/N 600-00082-000 Rev 04...
5.2 General Service Procedures Repair of the DC50 Datalink Coupler is performed at the factory, and includes a complete checkout. Prior to returning a unit for service, contact Avidyne at 1-888-723-7592 to obtain a Return Merchandise Authorization (RMA) number.
Category C Equipment tested to Humidity Category A Operational Shocks Equipment tested to & Crash Safety Category B Equipment tested to Vibration Category S, Curve B & M Avidyne DC50 Datalink Coupler Installation Manual Page 14 P/N 600-00082-000 Rev 04...
Page 19
Category TTX Emission of Radio Equipment tested to Frequency Energy Category M Lightning Induced Equipment tested to Transient Category A2E2 Susceptibility Lightning Direct Category X, no test Effects performed Avidyne DC50 Datalink Coupler Installation Manual Page 15 P/N 600-00082-000 Rev 04...
Page 20
Environmental RTCA/DO-160D Conducted Test Tests Section Category Category X, no test Icing performed Electrostatic Equipment tested to Discharge Category A Avidyne DC50 Datalink Coupler Installation Manual Page 16 P/N 600-00082-000 Rev 04...
Need help?
Do you have a question about the DC50 and is the answer not in the manual?