PF FF9000 Installation, Operation & Maintenance Manual

Automatic sliding gate

Advertisement

Quick Links

FF9000 Automatic Sliding Gate
Installation, Operation &
Maintenance Manual
Parking and access control equipment manufactured in the UK
Rev:8.0
Manual Barriers
Auto Sliding Gates
Auto Bi-Fold barriers
Auto Rising Kerbs
Auto Rising Bollards
Turnstiles

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FF9000 and is the answer not in the manual?

Questions and answers

Summary of Contents for PF FF9000

  • Page 1 Parking and access control equipment manufactured in the UK FF9000 Automatic Sliding Gate Rev:8.0 Installation, Operation & Maintenance Manual Manual Barriers Auto Sliding Gates Auto Bi-Fold barriers Auto Rising Kerbs Auto Rising Bollards Turnstiles...
  • Page 2 Parking and access control equipment manufactured in the UK Automatic Sliding Gates INDEX Page No: HEALTH & SAFETY INFORMATION DELIVERY, MOVEMENT & TRANSPORT COMPONENT IDENTIFICATION 05 - 07 PLC TIMER PROGRAMMING OPENING & CLOSING POSITIONS GATE USAGE PARAMETER LIST TROUBLESHOOTING GUIDE 12 - 13 WIRING DIAGRAM QUICK CONNECTION GUIDE...
  • Page 3: Introduction And Warnings

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Introduction and Warnings This equipment is part of a large range of traffic flow products. They are designed to be easy to install, as all settings and internal wiring has been completed in our factory. Any of the instructions in this manual should only be carried out by a qualified service engineer or a competent person.
  • Page 4 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Delivery, Movement & Transportaton This article describes how your equipment will be delivered to you, specifications on the transportation used and advice including health & safety on movement of the equipment. The gate should ALWAYS! be in the central position before any movement commences, this ensures that the gate does not distort or get damaged.
  • Page 5 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Component Identification & Notes You should check that you have received the following in your order as they are referred to throughout this manual (note this can change per gate spec i.e. manual components are different from automatic): O&M Manual 1 No.
  • Page 6 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Component Identification & Notes 60 5 45 mins 5/6. 7/8. 30mm Nut 30mm Nut Central Position 10/11. Beam shown to be level Transmitter Receiver Transmitter Receiver Spirit Level Co. 5.
  • Page 7 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Manual Operation & Maintenance Please use the following instructions to operate the gate manually, the following is assuming you have powered down the unit and opened the main tower door: 60 5 10 mins Keep pushing...
  • Page 8 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Opening & Closing Positions When you first turn the gate on you will need to calibrate the gate, this in laymans terms means teaching the open and close positions. You can also follow this guide should you need to re-teach the positions in the future.
  • Page 9 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Gate Usage Mobil Safety 4x Stationary Safety Mobil Safety (Closing) (Opening and Closing) (Opening) Optional TST FSAM RS485 TST Toolbox <-> Parameter update Diagnose Software update Update Controller Update WiCab There are many options to operate the gate and is dependant upon which type of access control you have connected.
  • Page 10 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Gate Usage 60 5 10 mins UP ARROW STOP STOP BUTTON STOP DOWN ARROW figure.1 figure.2 LED Letters or numbers .0.99 P.999 LED Dot figure.4 Normal State = Static Changed State = Flashing figure.3 ‘STOP’...
  • Page 11: Parameter List

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Parameter List Please note you DO NOT need to use these unless you have a problem!! 1. Follow the guide on page 10, to enter the menu. 2. Scroll to parameter P.990 change the value to 1 (this will default the panel to factory default) 3.
  • Page 12: Troubleshooting Guide

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Troubleshooting Guide Message Short description: Cause of message • current motor run time has exceeded set maximum run time (P.410 (Opening), P.415 (Closing), P.419 (Deadman move)), door Run time exceeded (during opening, F.020 may be sticking or is blocked closing or deadman)
  • Page 13 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Troubleshooting Guide Message Short description: Cause of message I.080 Service counter will run off I.100 Speed in open position to high I.150 Speed in close position to high I.160 Permanent open command still active I.161...
  • Page 14: Wiring Diagram

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Wiring Diagram...
  • Page 15: Quick Connection Guide

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Quick Connection Guide We have made the most common connections available without having to open the control panel cover see below for info. Please NOTE that you will have to enable the corresponding parameters to activate the inputs, as they are disabled in factory when testing the gates.
  • Page 16: Master/Slave Wiring

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Master/Slave Wiring 3 wires only 4 3 2 4 3 2 Normal Photocell Wiring Master Catch Post Yellow/Brown Wire to main panel IN 7 Grey Terminals 86/85/84 Blue Yellow/Brown Grey Blue...
  • Page 17 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Wireless Encoder...
  • Page 18 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Wireless Encoder...
  • Page 19 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Wiring & Programming Every input/output is highly configurable, and can be changed from its default/state use. The below is a guide to what they can be changed to and the effect of this change. The logic behind this is as follows: On the wiring diagram each terminal has an input number this is noted as “IN6"...
  • Page 20 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Wiring & Programming Outputs Parameter Unit Range Function Description/Value of Parameter P.7x0 0 ..27 Switching Condition With this parameter the functionality for parameter x is set. of output relay Notes Area...
  • Page 21: Loop Detector Settings

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Loop Detector Settings 1 INTRODUCTION The PD130 is a single channel microprocessor based detector designed specifically for parking and vehicle access control application. The PD130 has been designed using the most up-to-date technology in order to meet the requirements of a vast number of parking applications (in terms of operating conditions and options available to the user.) The primary function of the detector is to detect vehicle presence by means of an inductance...
  • Page 22: Operating Procedures

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Loop Detector Settings Figure 5.2 Slot Details 3 OPERATING PROCEDURES 3.1 Hardware Set-Up The PD130 single channel parking detector is designed to be shelf or DIN rail mounted, with the controls and visual indicators at the front, and wiring at the rear of the enclosure.
  • Page 23 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Loop Detector Settings 3.2.2 Sensitivity The sensitivity of the detector allows the detector to be selective as to the change of inductance necessary to produce a detect. There are four sensitivity selections and are set as follows: - SW4 SW3 Off...
  • Page 24 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Loop Detector Settings...
  • Page 25 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Troubleshooting Guide ELECTRICAL ERRORS CAUSE CORRECTION Door switch circuit not making Press door switch in and check Panel screen Blank screen on Panel but power to other devices Panel has developed an electrical fault or had a Change fuses or panel MAKE SURE that the in the control panel...
  • Page 26 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Troubleshooting Guide MECHANICAL ERRORS CAUSE CORRECTION Gate not Moving Motor brake locked on Check brake is releasing Gate creaking when moving Gate alignment Check and align gate correctly Gate motor not running Loss of voltage Check motor supply test 3 phases...
  • Page 27 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Potential System Hazard Areas Please note these are things that you should look out for with the equipment that has been installed on your/your customers site. This is in no way a health and safety guide just a few key areas for you to be aware of and possibly make future changes to.
  • Page 28 UPS Battery back-up used for panel protection and gate can open/close automatically after power loss. HIGHLY RECOMMENDED! Section 5.a Delivery or Install Address PF to install equipment PF to supply only Section 5.b Additional Information (Use a separate sheet if necessary)
  • Page 29: Installation & Commissioning Check List

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Installation & Commissioning Check List System Operation - The user FULLY understands How to operate the system with all control devices How to isolate the power to the automation system How to manually release the system in event of power failure The safety rules and issues associated with your system Safety devices on the system have been verified and checked...
  • Page 30: Service Log

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Service Log This Manual must be completed in accordance with the guidelines below, at any point service/repair work is carried out on the product. This is to achieve two things; 1.
  • Page 31: Commissioning Certificate

    Parking and access control equipment manufactured in the UK Automatic Sliding Gates Commissioning Certificate We certify that the system covered by this certificate has been commissioned satisfactorily. Contract Reference Completion Contract Title Engineers Installing Installation Commenced Commissioning Works Description Part/Whole Certificate Handover Date Part 3.The system(s) designed and installed in accordance with the following documents: Document Ref:...
  • Page 32: Declaration Of Conformity

    We hereby certify that the machinery stipulated below complies with all relevant provisions of the EC Machinery Directive and National Laws and Regulations adopting this Directive. Manufacturer PF Ltd & European Unit 1 Kingsbury Link Industrial Estate Agent: Trinity Road Tamworth Staffs...
  • Page 33 Parking and access control equipment manufactured in the UK Automatic Sliding Gates Electronics Certificate...
  • Page 34 Parking and access control equipment manufactured in the UK Automatic Sliding Gate EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF THE STANDARDS 2006/42/EC Proudly Proudly Made in the UK 2003/108/CE Directive for waste electrical and Made using electronic Equipments recycled DISPOSE OF PROPERLY paper...

Table of Contents