MINI
General introduction:
Cylinder
Passage mode
button
Unlocking way: Fingerprint, card, mechanical key
User: 1pcs Master fingerprint, 99pcs normal fingerprint user, 100pcs card user.
Card wake button: press the card wake button first, then unlock by card
Power connector: when power off, connect it with charge pal to unlock with
fingerprint/card.
Low voltage warning: when voltage lower than 4.6±0.2V,lock will beep with red
light after input fingerprint/card user.
Operation manual:
1. Reset
Press setting button (use the pin) until 5 times beep with red and blue light
blink----resetting successful]
Note: After resetting, any fingerprint/card can open the door until regist the
master fingerprint. It is just convenient for using.
2. Add master fingerprint
Press setting button for one time----2 beeps with red light—
--put the master fingerprint on the finger sensor to register for three times( each
time with one beep)----blue light with 3 beeps mean register successful (Red light
means failure, need to register again.)
3. Add normal fingerprint user
Press setting button---2 beeps with red light
--Input master fingerprint----blue light means verification successful (red light
means verification failed, input correct master fingerprint again.)
Fingerprint sensor
Outside handle
Setting button
Inside handle
Outside handle
Power connector
Card wake button