Download Print this page

A.O. Smith GW/GWO-1000 Specification Sheet page 3

A.o. smith hot water supply boiler specification sheet

Advertisement

OUTDOOR MODELS
MODEL
DIM. "A" DIM. "B"
GWO-1000
66.00
58.67
GWO-1300
76.50
58.67
GWO-1500
83.50
58.67
GWO-1850
97.50
61.37
GWO-2100
104.50
61.37
GWO-2500
118.50
61.37
DIRECT VENT (HORIZONTAL)
DIRECT VENT (VERTICAL)
Combustion
Model
Vent Size
Air Intake
GW-1000
10'
8'
GW-1300
12'
10'
GW-1500
12'
10'
GW-1850
14'
12'
GW-2100
14'
12'
GW-2500
16'
14'
See installation manual for additional venting information further details.
Notes: * Maximum three elbows
** Maximum two elbows -each- lntake/Exhaust
90/45 degree elbows are equivalent to 10/5 feet of vent pipe respectively.
All venting configurations terminating horizontially are Category III and require AL29-4C venting material.
All venting configurations terminating vertically are Category I and can use type B venting material (Except where local codes require
AL29-4C sealed venting material.)
31.59
B
DIRECT VENT (VERTICAL)
SIDEWALL VENTING
Natural Draft
Max. Distance W/O
Barometric Damper / With
Sidewall
Barometric Damper
Venting*
35' / To Roof
35' / To Roof
35' / To Roof
35' / To Roof
35' / To Roof
35' / To Roof
A
Sidewall Venting
W/Opt. Extended Vent
Kit (Power Assisted)
70'
110'
70'
110'
70'
110'
35'
110'
35'
110'
35'
110'
18.25
17.39
DIRECT VENT (HORIZONTAL)
NATURAL DRAFT
Direct Vent
W/Opt. Extended Vent
Direct Vent*
Kit (Power Assisted)
35' / 35'
60' / 60'
35' / 35'
60' / 60'
35' / 35'
60' / 60'
15' / 15'
60' / 60'
15' / 15'
60' / 60'
15' / 15'
60' / 60'
A 012.17
18.07

Advertisement

loading

This manual is also suitable for:

Gw/gwo-2500Gw-1000Gw-1300Gw-1500Gw-1850Gw-2100 ... Show all