4.1.5.
line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should be
1/4" internal diameter and fittings must have compatible dimensions.
4.1.6.
Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections are secure.
4.2.
COUPLINGs
Vibration may cause failure if a quick change coupling is connected directly to the drill. To overcome this, connect a leader hose to the
drill (Sealey ref: AH2R or AH2R/38). A quick change coupling may then be used to connect the leader hose to the air line recoil hose. See
fig's 1 & fig 2.
fig 1
5. OPERATION
WARNING! ensure you read, understand and apply Section 1 safety instructions.
5.1.
Turn front of chuck head to open, insert drill bit and turn chuck head to lock drill bit.
5.2.
Connect the drill to the air hose as described in Section 4.
5.3.
Push the safety lock forward and depress the throttle lever to operate the drill accordingly.
5.4.
The flow of air may be regulated by turning the large headed screw on the drill body opposite the trigger mechanism.
6.
MAINTENANCE
WARNING! disconnect drill from air supply before changing accessories, servicing or performing maintenance. Replace or repair
damaged parts. Use genuine parts only. non-authorised parts may be dangerous and will invalidate the warranty.
6.1.
lubricate the air drill daily with a few drops of Sealey air tool oil dripped into the air inlet to prolong its life.
6.2.
Clean the drill after use.
6.3.
loss of power or erratic action may be due to the following:
a)
excessive drain on the air line. moisture or restriction in the air pipe. Incorrect size or type of hose connectors. To remedy
check the air supply and follow instructions in Section 3.
b)
Grit or gum deposits in the drill may also reduce performance. If your model has an air strainer (located in the area of
the air inlet), remove the strainer and clean it. Flush the drill out with gum solvent oil or an equal mixture of SAe no 10 oil
and paraffin. Allow to dry before use.
6.4.
For a full service contact your local Sealey service agent.
6.5.
When not in use, disconnect from air supply, clean drill and store in a safe, dry, childproof location.
This tool may cause Hand Arm Vibration syndrome if its use is not managed adequately.
This tool is subject to the vibration testing section of the machinery directive 2006/42/eC.
This tool is to be operated in accordance with these instructions.
Measured vibration emission value (a): 0.461m/s²
Uncertainty value (k): 0.541m/s²
Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend that a
specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.
A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool.
NB: Stated Vibration emission values are type-test values and are intended to be typical.
Whilst in use, the actual value will vary considerably from and depend on many factors.
Such factors include; the operator, the task and the inserted tool or consumable.
NB: ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration.
The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm Vibration
Syndrome.
Health surveillance.
We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified
accordingly.
Personal protective equipment.
We are not aware of any personal protective equipment (PPe) that provides protection against vibration injury that may result from the
uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry and
maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the Correct Use and
maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the HSe website
www.hse.gov.uk - Hand-Arm Vibration at Work.