Download Print this page

LG 49UF6400 Service Manual page 16

Hide thumbs Also See for 49UF6400:

Advertisement

4.2.3. Equipment connection MAP
Probe
USB to RS-232C
If you want to use Signal Source,
you use TV internal Flicker pattern
4.2.4. Adj. Command (Protocol)
<Command Format>
CMD ID DATA CR RF
-. CMD: Command
-. ID : Command
-. Data : Command
Ex) [Send: va 00 00\r\n]
▪ RS-232C Command used during auto-adj.
RS-232C COMMAND
[CMD
ID
DATA]
va
00
00
vb
00
00 ~ FE V-com adj.(internal Flicker pattern)
wb
00
FF
4.2.5. Adj. method
(1) Set TV in POWER-ONLY mode using POWER ONLY key
(2) Zero calibrate probe then place it on the center of the
Display
(3) Connect Cable (RS-232C to USB)
(4) Select Model in "V-com adj. Program" and begin "V-com
adj."
(5) When V-com adj. is complete (OK)
(6) Remove probe and RS-232C to USB cable to complete
adjustment.
▪ V-com Adj. must begin as start command "va 00 00", and
finish as end command "wb 00 ff"
▪ V-com adjust data
- 43 inch
hex
Max
Default
Min
- 49 inch
hex
Max
Default
Min
- 55 inch
hex
Max
Default
Min
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Flicker Analyzer
RS-232C
Computer
Explanation
V-com pattern
V-com adj. completed
V-com Data
dec
B4
180
96
150
78
120
V-com Data
dec
8B
139
6D
109
4F
79
V-com Data
dec
85
133
68
104
49
73
- 65 icnh
Max
Default
Min
4.3. White Balance Adjustment
4.3.1. Overview
▪ W/B adj. Objective & How-it-works
(1) Objective: To reduce each Panel's W/B deviation
(2) How-it-works : When R/G/B gain in the OSD is at 192, it
means the panel is at its Full Dynamic Range. In order to
prevent saturation of Full Dynamic range and data, one
of R/G/B is fixed at 192, and the other two is lowered to
find the desired value.
(3) Adjustment condition : normal temperature
1) Surrounding Temperature : 25 °C ± 5 °C
2) Warm-up time: About 5 Min
3) Surrounding Humidity : 20 % ~ 80 %
4.3.2. Equipment
(1) Color Analyzer: CA-210 (LED Module : CH 14)
(2) Adjustment Computer(During auto adj., RS-232C protocol
is needed)
(3) Adjustment Remote control
(4) Video Signal Generator MSPG-925F 720p/216-Gray
(Model: 204, Pattern: 49)
→ Only when internal pattern is not available
Color Analyzer Matrix should be calibrated using CS-100.
4.3.3. Equipment connection MAP
Probe
4.3.4. Adj. Command (Protocol)
<Command Format>
START 6E
A
50
A LEN A 03 A
- LEN: Number of Data Byte to be sent
- CMD: Command
- VAL: FOS Data value
- CS: Checksum of sent data
- A: Acknowledge
Ex) [Send: JA_00_DD] / [Ack: A_00_okDDX]
- 16 -
V-com Data
hex
dec
AB
171
8D
141
6F
111
Co lo r Analyzer
RS -232C
Co m p ut er
RS -232C
RS -232C
Pat t ern Generat o r
Signal Source
* If TV internal pattern is used, not needed
CMD
A
00
A
VAL
A
LGE Internal Use Only
CS STOP

Advertisement

loading

This manual is also suitable for:

43uf640043uf6400-ca49uf6400-ca