1. Purpose of this manual 1.1 This manual applies exclusively to the solar photovoltaic module (hereinafter referred to as Module) of AE SOLAR. The contents of this manual involve the installation methods, operation safety and maintenance information. 1.2 Modules must be installed by professionals. Please read this manual carefully before installation. The installers must follow all the rules in this manual strictly as well as local requirements and regulations by law or authorized organizations.
Page 4
not pull the wiring cables or junction Both hands when handling Modules Do not use sharp objects with Modules Ensure Modules are fixed properly Do not touch Modules with bare or dirty Do not stamp on Modules Do not pile up Modules on uneven ground Do not drop or throw Modules hands 3.4 Storage and unpacking...
Mechanical installation 4.1 Installation site Modules can be installed in land area in addition to the salt water, acid and alkali corrosion. For the modules installed near the coastline, the location of the modules should greater than 1000m away from the coastline at high tide.
Page 6
It is not allowed to drill the hole in the glass surface or frame of the module. Otherwise ,the guarantee will be invalidated. When to install the Modules on the roof, it is necessary to guarantee the roof structure is suitable for ...
Page 7
4.5 Mounting with clamps When choosing this type of mounting method, please be sure use at least 4 clamps on each module and no module clamps shall contact or make any shading on the modules glass. An integrated M8 hex head cap screw tightens down to the frame with a torque between 12.5-18 NM Method Installed Frame(L)
5. Electrical installation DC power generated by the photovoltaic system can be converted into AC power and fed into the grid. Policies on connecting renewable energy system to the grid vary from region to region. Consult senior system designer before designing the system. Generally, the system installation shall be formally approved by the local public sector.
Page 9
Make sure the electric components such as the connectors and inverters are off-state during the installation. To reduce lightning damage, the loop area should be kept as small as possible when laying cables. It is recommended to use fuses in each string. 5.2 Grounding The modules are designed with anodized corrosion-resistant aluminum alloy frames as rigid supports.
6. Bypass diodes and current protection 6.1 Bypass diodes In a system with two or more Modules connected in series, if part of a Module is shaded while the other part is exposed to the sun, a very high reverse current will go through the cells which have been partly or entirely covered and it will cause overheat on the cells, which may damage the Module.
gloves for maintenance. The back surface of the module normally does not need to be cleaned but, in the event this is deemed necessary, avoid the use of any sharp projects that might damage the penetrating the substrate material. 8.
Page 12
AE375M6-72 AE380M6-72 AE385M6-72 NominalMax.Power Pmax (Wp) Maximum Power Voltage Vmp (V) 40.20 40.5 40.80 Maximum Power Current Imp (A) 9.33 9.39 9.44 Open-Circuit Voltage Voc (V) 47.9 48.1 48.3 Short-Circuit Current Isc (A) 10.13 10.17 10.21 AE315M6-60 AE320M6-60 NominalMax.Power Pmax (Wp) Maximum Power Voltage Vmp (V) 33.20...