A measured step forward MAGDOS LC Operation & Maintenance Instructions Read these operation & maintenance instructions before start up! To be held for future reference. Dosing Liquids Conveying Gases Control Systems...
1. Safety 1.1 General This Operation & Maintenance Manual contains basic information to be noted during installation, operation and maintenance. It is therefore essential that the Manual is read by the contractor before installing and commissioning the pump/system as well as by the relevant operating personnel / owner of the pump/system.
1.3 Qualification and training of personnel The personnel employed for installation, operation, inspection and maintenance must be qualified for this work. The areas of responsibility, competence and supervision of the personnel must be precisely defined by the owner. Personnel who do not have the required knowledge must be duly trained and instructed.
The dosing pump may only be modified or converted in consultation with the manufacturer. Genuine spare parts and accessories authorized by the manufacturer ensure greater safety. Liability for damage or loss may be voided if non Lutz-Jesco parts are used.
Page 6
CAUTION! • Chemical could spray out. This may lead to caustic or other burns. Always relieve the system/pump pressure before starting work on the dosing pump. • Before working on the dosing head, check valves and connections, flush the pump’s CAUTION! wetted end with a harmless medium (mainly water) to avoid unintentional contact with the metered medium.
CAUTION! Malfunctions may arise in • Circuits CAUTION! • Magnetic strips • Mobile phones if brought in direct vicinity of the stroking solenoid. 1.11 Scope of delivery IMPORTANT! Please unpack the dosing pump and ordered accessories carefully in order not to miss IMPORTANT! small parts.
3. Description Legend: 1 Solenoid coil 2 Solenoid armature 3 Stroke adjustment 4 Electronic unit 5 Drain pipe 6 Suction valve 7 Dosing head 8 Discharge valve 9 Diaphragm 1 0 Diaphragm return spring The solenoid coil of the drive solenoid is activated in a pulsating manner by the electronic unit in the MAGDOS LC dosing pump.
5. Technical data MAGDOS LC Max. pressure* [bar] Flow rate at max. pressure* [l/h] Medium pressure* [bar] Flow rate at medium pressure* [l/h] Max. stroke frequency [1/min] Suction lift [mH O] for non-effervescent media Max. supply pressure [mbar] Power supply 115 V AC or 230 V AC +/- 10% 50/60 Hz Power supply cable...
The performance curves refer to water at 20 °C (68 °F). The performance of the dosing pump depends on the viscosity of the process fluid and hydraulic installation conditions. Dosing pumps must therefore be gauged in litres during application. MAGDOS LC 2 10 bar 145 psig...
7. Installation 7.1 General notes of instruction For the selection of a dosing pump when designing a system as well as for the installation and operation, local rules and regulations must be obeyed. This applies to the selection of appropriate materials of construction, the handling of the chemicals and the electrical installation.
avoided. If the dosing pump is installed outside, provide a roof to protect it against weather. 7.3 Electrical connection DANGER! • Fire hazard. Pressure surge: parts may burst and cause fatal injury. DANGER! Magdos LC must never be used in an explosion-proof area. The electrical connection of the dosing pump must be made according to the local rules and regulations and may only be carried out by technical personnel.
Injection fitting mounted from above Injection fitting mounted from below (for media with a tendency to crystallize) 7.6 Installation examples on chemical tank Legend MAGDOS LC Chemical tank on wall bracket Suction line Wall bracket Mounting Hardware Magdos Pump Riser Base (p/n 37558) Mounting of Magdos LC to Wall Bracket, Tank Mounting Plate, and Pump Riser Base Legend...
Installation example Legend MAGDOS LC Chemical tank Suction line Priming aid Electric agitator Pulsation dampener Injection nozzle with non-return and shutoff valve Back pressure regulating valve Pressure relief valve (safety valve) 8. Operation Control panel MAGDOS LC Legend Stroke adjustment with scale and locking screw Mains cable...
8.1 Setting of flow rate Volumetric displacement per dosing stroke The stroke length adjustment limits the movement of the diaphragm. Adjusting the stroke length does not have a linear proportional effect on the stroke volume. The volume per dosing stroke is shown in the performance curves or displayed on the dosing pump’s calibration table.
11. Maintenance Dosing pumps are produced according to the highest quality standards and have a long service life. Nevertheless some parts are subject to wear caused by operation (e.g. diaphragm, valve seats, valve balls). To ensure a long operating life, visual inspection is recommended regularly.
Page 18
Replacing the diaphragm 1. Remove the dosing head with a suitable tool (size 3 Allen key). Figure 1 2. With the dosing pump operating, adjust stroke length setting to 0% and then turn pump off. Insert the locking pin (Art. No.
Page 19
5. Grease the diaphragm rod with Molykote DX at the contact point with the housing bushing and along the diaphragm thread. 6. Push the support plate onto the threaded connector of the new diaphragm with the concave side facing towards the diaphragm. Figure 4 7.
11.2 Inspecting and replacing the deflector plate CAUTION! Chemical could spray out. This may lead to caustic or other burns. The dosing head must always be depressurized and rinsed with water or a suitable medium before starting any work on the dosing pump. CAUTION! The following steps are required to verify that the deflector plate...
11.3 Check valves The dosing pump check valves must be cleaned regularly. CAUTION! Chemical could spray out. This may lead to caustic or other burns. The dosing pump CAUTION! must always be depressurized and rinsed with water or a suitable medium before starting any work on the dosing pump.
Page 22
Spring-loaded check valve Discharge Suction check valve check valve Legend 1. O-Ring 2. Valve seat 3. Valve ball 4.*Ball guide 5. Gasket 6. *Valve body 7.* Hose clamp 8.*Nut 9. Spring *not included in spare parts kits.
11.4 Drive solenoid DANGER! Components are energized! Electric shocks can kill! Unplug the mains connector before opening the pump. DANGER! CAUTION! Hot metal parts may burn your hands. Always disconnect the mains power supply before opening the magnetic drive and let the dosing pump cool down for at least one hour.
11.5 Correction of stroke length adjustment IMPORTANT! After replacing the diaphragm or other spare parts it might become necessary to readjust the dosing pump. IMPORTANT! Legend Stroke length adjusting knob Locking screw 1. Switch power on. 2. Regardless of the indicator position, loosen the locking screw and turn the stroke length adjusting knob counterclockwise until the dosing pump no longer delivers or, in the case of pressureless operation, only delivers minimum.
12. Spare parts list MAGDOS LC 2 ... 6 Spring-loaded Double ball Diaphragm, PTFE-coated EPDM 81424 check valve check valve Support plate 37094 Drive: 230 V AC 37609 115 V AC 37610 Control unit: 230 V AC 37611 115 V AC 37612...
Page 27
Spare parts list for MAGDOS LC with spring-loaded check valves Consists of: Material Part No.: Gaskets Valve balls Springs PVC / Glass / Viton 37659 Valve seats PVC / Glass / EPDM 37660 O-rings PP/ Glass / Viton 37659 Diaphragm PVC/ Glass / EPDM 37660 Spring-loaded check valve complete...
This declaration is no assurance of characteristics in the sense of the product liability law. The safety notes in the operation & maintenance instructions must be obeyed. EC – Declaration of Conformity Lutz-Jesco GmbH Am Bostelberge 19 D – 30900 Wedemark...
(i.e. chemical, biological, toxic, flammable, and radioactive material) and that the lubricant has been drained.*) If Lutz-Jesco has to (further) clean the unit the costs will be charged to us. We assure that the aforementioned information is correct and complete and that the unit is dispatched according to the legal requirements.
Dimensions for the USA 3.54" 0.236" 2.76" 3.03" 3.31" 3.94" 4.72" ~8.27" Connection „L“ Dimension 4/6 - 4/6 4.96“ 1/4“ x 3/8“-1/4“ x 3/8“ 5.28“ 4/6 - 1/4“ x 3/8“ 5.12“ All dimensions in inches.
Max. sound pressure level [dB(A)] at test pressure Connection type (standard) 1/4“x 3/8“ PE-tubing Check valves MAGDOS LC 2 ... LC 6 USA Double ball check valve complete Spring-loaded check valve complete with connection 1/4"x 3/8" with connection 1/4"x 3/8"...
Page 36
Internet: www.lutz-jesco.de Internet: www.lutz-jesco.nl Internet: www.lutz-jesco.hu East Asia Middle East Lutz-JESCO America Corp. Lutz-Jesco Lutz-Jesco Middle East FZE East Asia Sdn Bhd P.O. Box 9614 55 Bermar Park Rochester, NY 14624 Taman Perindustrian Jaya SAIF-Free Zone Center 47200 Petaling Jaya...