Do you have a question about the Telect 350CB06 and is the answer not in the manual?
Questions and answers
Summary of Contents for Amphenol Telect 350CB06
Page 1
Dual-Feed 350A 6-Circuit Breaker/TFD Distribution Panel with 5 GMTs Installation Guide...
Page 2
Amphenol Network Solutions assumes no liability from the application or use of these products. Amphenol Network Solutions does not convey any license under its patent rights nor the patent rights of others. This document and the products described herein are subject to change without notice.
15A or less. Each of the dual feeds contains six interrupter positions for either bullet-style REC switch (ON/OFF) circuit breakers or TFD holders. Each feed also includes five GMT fuses. Go to amphenol-ns.com to order circuit breakers, TFD holders and GMT fuses: Fig. 1: 350CB06 Distribution Panel TLS fuses up to 70A rated, continuous current 80% of rated •...
(e.g. use of power strips). Disconnect Device – A readily disconnect device shall be incorporated in the building installation wiring. • Dual-Feed 350A 6-Circuit Amphenol Network Solutions Breaker/TFD Distribution All rights reserved. 12.16.19 138661-5 A0 509.926.6000 – amphenol-ns.com...
6-32 panhead screws [max. lug width of 0.32 in. (8.1 mm)]. Torque to 6.3 in-lb. (0.7 N•m). Output wire size* #22 AWG to #12 AWG Dual-Feed 350A 6-Circuit Amphenol Network Solutions Breaker/TFD Distribution All rights reserved. 12.16.19 138661-5 A0 509.926.6000 – amphenol-ns.com Panel with 5 GMTs...
Page 7
Only qualified technicians may install and maintain this product. Dual-Feed 350A 6-Circuit Amphenol Network Solutions Breaker/TFD Distribution All rights reserved. 12.16.19 138661-5 A0 509.926.6000 – amphenol-ns.com...
When you receive the equipment, carefully unpack it and compare it to the packaging list. Please report any defective or missing parts to Amphenol Network Solutions Quality at quality@amphenol-ns.com or call 1.509.926.6000. Amphenol Network Solutions is not liable for transit damage. If the product is damaged, please report it to the carrier and contact Amphenol Network Solutions Quality.
5. Remove the cover. WARNING! Failure to properly ground this equipment can create hazardous conditions to installation personnel and to the equipment. Dual-Feed 350A 6-Circuit Amphenol Network Solutions Breaker/TFD Distribution All rights reserved. 12.16.19 138661-5 A0 509.926.6000 – amphenol-ns.com Panel with 5 GMTs...
Ambient operating temperature affects the type of input wire insulation. For further information consult the National Electrical Code (NEC). Dual-Feed 350A 6-Circuit Amphenol Network Solutions Breaker/TFD Distribution All rights reserved. 12.16.19 138661-5 A0 509.926.6000 – amphenol-ns.com Panel with 5 GMTs...
NC. ∞ Expect an open circuit ( Ω) between Terminals • C and NO. Fig. 6: Alarm Faceplate Dual-Feed 350A 6-Circuit Amphenol Network Solutions Breaker/TFD Distribution All rights reserved. 12.16.19 138661-5 A0 509.926.6000 – amphenol-ns.com Panel with 5 GMTs...
[handle] is down.) Then install circuit breakers or fuse holders and fuses for the dual-hole lug outputs, as shown in Figure 9. 35. Again, make sure the load devices are disabled and then install the GMT fuses, as shown. Dual-Feed 350A 6-Circuit Amphenol Network Solutions Breaker/TFD Distribution All rights reserved. 12.16.19 138661-5 A0 509.926.6000 – amphenol-ns.com...
37. If possible, temporarily replace one of the operable GMT fuses with a blown fuse to check that the applicable ALARM LED lights up red. Also, check the ALARM terminal on the rear of the panel: Dual-Feed 350A 6-Circuit Amphenol Network Solutions Breaker/TFD Distribution All rights reserved. 12.16.19 138661-5 A0 509.926.6000 –...
40. Lastly, enable equipment loads one at a time to verify the proper operation of loads. 41. This procedure is complete. NOTE: For service or warranty, see our amphenol-ns.com website and click on the “Support” tab, email inquiries to getinfo@amphenol-ns.com or phone us at 1.509.926.6000.
Solder splash protection 116915 Amphenol Network Solutions assumes no liability from the application or use of these products. Neither does Amphenol Network Solutions convey any license under its patent rights or the patent rights of others. This document and the products described herein are subject to change without notice.
ALARM ALARM in alarm condition BREAKER ALARM CIRCUIT BREAKER FAIL INPUT POWER B GREEN C GND BATT Input BATT Dual-Feed 350A 6-Circuit Amphenol Network Solutions Breaker/TFD Distribution All rights reserved. 12.16.19 138661-5 A0 509.926.6000 – amphenol-ns.com Panel with 5 GMTs...