Panasonic NA-148VB6WDE Service Manual page 34

Drum type washing machine
Table of Contents

Advertisement

11.9. Circulation Pump
The component is used for circulation of water inside the
drum in order to increase washing performance.
Check the resistance value on the component with multimeter as shown below.
You can determine the ohm value by measuring from the red cable at 5th and red cable at 12th position in the small socket
(refer wiring diagram in section 12) as shown below figure. Resistance value should be between 160- 180 Ω
Technical features
Nominal voltage
Frequency
Resistor (coil)
Testing component
Resistance value should be between 160- 180 Ω
th
5
pin Red Cable
th
12
pin Red Cable
Component test
Circulation Pump
220 - 240 V
50 Hz
169,5 Ω (±5%)
34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Na-148vb6wtaNa-148vb6wgnNa-148vb6wgb

Table of Contents