EL.MO. Spa FX/20 User Manual

Analogue addressable fire panel

Advertisement

Quick Links

COMPLIANCE WITH
EN 54 - 2 1997
UNI EN 54 - 2 - 1999
CONTROL UNITS
Analogue Addressable Fire Panel
EN 54 - 4 - 1997
UNI EN 54 - 4 - 1999
POWER SUPPLY UNITS
FX/20
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FX/20 and is the answer not in the manual?

Questions and answers

Summary of Contents for EL.MO. Spa FX/20

  • Page 1 EN 54 - 4 - 1997 COMPLIANCE WITH EN 54 - 2 1997 UNI EN 54 - 4 - 1999 UNI EN 54 - 2 - 1999 POWER SUPPLY UNITS CONTROL UNITS Analogue Addressable Fire Panel FX/20 USER MANUAL...
  • Page 2 FX/20 - USER MANUAL FOREWORD FOR THE INSTALLER: Please follow carefully the specifications on electric and security systems realization further to the manufacturer’s pre- scriptions indicated in the manual provided. Provide the user the necessary indication for use and system’s limitations, specifying that there exist precise specifi- cations and different safety performances levels that should be proportioned to the user needs.
  • Page 3: General

    FX/20 panel has been designed for fire detection systems management and is particularly suitable for large- size installations, such as those in hotels, company buildings, shopping centres and office blocks, all areas re- quiring high technological performance, quick installation, and easy management.
  • Page 4: User Interface

    FX/20 - USER MANUAL 2. USER INTERFACE FX/20 control panel is equipped with a large metal housing. On the front panel there is a label indicating all LEDs functions and control keys. Front label view: 3. LED DISPLAY INDICATIONS AND MENU 3.1 Normal operating status...
  • Page 5: Fire Alarm Event Condition

    USER MANUAL - FX/20 3.2 Fire alarm event condition 3.3 Reset procedure TO GO BACK TO NORMAL OPERATING STATUS: RESET PROCEDURE OF AN PRESS "ESC", ALARM CYCLE, A FAULT CYCLE, SELECT "EXIT TO LEVEL 1", OR A MALFUNCTION CYCLE. ACCESS LEVEL UNCHANGED.
  • Page 6: Access With User's Password

    FX/20 - USER MANUAL 3.4 Access with user’s password There are four access levels: 1 = BASIC level (public level) 3 = MAINTENANCE level 2 = USER level 4 = MANUFACTURER level To access different levels, digit the relevant password set.
  • Page 7: Test Menu

    USER MANUAL - FX/20 3.6 Test menu...
  • Page 8: Enablement Menu

    FX/20 - USER MANUAL 3.7 Enablement menu First diagram: KEYS FUNCTION TO ENTER USER PASSWORD A MENU OR CHANGE THE ITEM SELECTED TO SWITCH DIS = DISABLED ENABL = ENABLED (EXCLUDED) (INCLUDED) NOTE: HERE ZONES ARE INDICATED ONLY IN GENERAL TERMS.
  • Page 9 USER MANUAL - FX/20 Second diagram: DISPLAY OF RELAY 2 DISABLED (EXCLUDED) TO SWITCH NOTE: IF YOU DISABLE A DIS = DISABLED BELL, THE SUPERVISION (EXCLUDED) OF THE CONTROL LINE IN CASE OF A BELL ALARM, ENABL = ENABLED THIS LED WILL LIGHT ON.
  • Page 10: Display Menu

    FX/20 - USER MANUAL 3.8 Display menu First diagram: KEYS FUNCTION TO ENTER A MENU OR CHANGE THE ITEM SELECTED USER PASSWORD MESSAGES TO DISPLAY IN CASE OF FIRE EVENT, THE BATTERY OF THE NO DATA TRANSMITTED FROM MESSAGES WITH LOWER PRIORITY...
  • Page 11 USER MANUAL - FX/20 Second diagram: EVENTS LIST DISPLAY KEYS FUNCTION THE FIRST EVENT DISPLAYED (4000 total) WILL BE THE OLDEST “SYSTEM RESET” EVENT. SET THE EVENTS FILTER (SEE ABOVE) IF YOU WANT TO DISPLAY ONLY PART OF THE EVENTS LOGGED.
  • Page 12: Print Menu

    FX/20 - USER MANUAL 3.9 Print menu USER PASSWORD KEYS FUNCTION ENTER A MENU OR CHANGE A SELECTION KEYS FUNCTION TO EDIT SAVE CHANGES SETTINGS AND EXIT THE MENU OFF LINE = PRINTER OFF LINE (DEFAULT) EVENTS LOG = PRINT ALL SYSTEM EVENTS...
  • Page 13: General Setup Tables

    USER MANUAL - FX/20 4. GENERAL SETUP TABLES It is strongly recommended to copy the following tables (showing operator’s general setup) to a different location, write all settings down and keep them in a safe place. • Password: A - Set Level 2 access passwords: 1234 LEV1 ->...
  • Page 14 FX/20 - USER MANUAL • Panel Outputs: C - LCD display test D - Panel output test: BELL A BELL B RELAY 2 Test OK Test OK Test OK Test failed Test failed Test failed E - Loop output test : digit ’L’ and ’A’ addresses:...
  • Page 15: Enablement Menu

    USER MANUAL - FX/20 4.2 Enablement menu Set: zone, device, panel output, delayed mode. Enabled zones (YES) Bypassed zones (NO) Enabled loop outputs (ON) Disabled loop outputs (OFF) Enabled panel outputs (ON) Disabled panel outputs (OFF) Delayed mode 4.3 Display Menu 1.
  • Page 16: Properties Tables

    FX/20 - USER MANUAL 5. PROPERTIES TABLES Table 1 Generated Activat. Generated Activat. DEVICE/PROPERTIES Type System System Logic Logic Event Event Event Event AS Heat Detector Heat FIRE EV Heat Detector Heat FIRE AS Optical Smoke Detector Optic FIRE EV Optical Smoke Detector...
  • Page 17 USER MANUAL - FX/20 Origin Event message Class Origin Generated* Activation* SYSTEM PANEL Bell/RELAY RELAY ENABLED FAULT PANEL FAULT Bell OPEN CIRCUIT FAULT FAULT Bell SHORT CIRCUIT PANEL SYSTEM PANEL Bell PASSWORD ACCESS SYSTEM PANEL Bell DELAYED MODE ENABLED SYSTEM...
  • Page 18: Note

    FX/20 - USER MANUAL 6. NOTE...
  • Page 19: Glossary

    USER MANUAL - FX/20 7. GLOSSARY - Self Learning: function allowing the control unit to automatically acknowledge devices connected to a loop by reading their analogue values and comparing them to preset tables. - Serial Bus: (bit) data transfer system used by the various parts of an electronic system for communica- tions (sequencially).
  • Page 20: Table Of Contents

    Product specifications as described above do not bind the manufacturer and may be altered without prior notice. EL.MO. SpA Global Security Solutions Via Pontarola, 70 - 35010 Reschigliano di Campodarsego (PD) - Italy Tel. +39 0499203333 (R.A.) - Fax +39 0499200306 - Technical Ass. +39 0499200426 - www.elmo.it - info@elmo.it...

Table of Contents