Mitsubishi Electric MSZ-GF60VE - E1 Service Manual page 25

Table of Contents

Advertisement

OPERATION INDICATOR
Abnormal
No.
Operation indicator lamp
point
All lamps fl ash at the same time.
Attachment
0.5-second ON
1
of the hori-
zontal vane
0.5-second OFF
OPERATION INDICATOR
Abnormal
No.
Operation indicator lamp
point
Upper lamp lights and lower lamp fl ashes.
MXZ type
Operation
1
mode
2.5-second OFF
setting
10-5. TROUBLE CRITERION OF MAIN PARTS
MSZ-GF60VE MSZ-GF60VE2 MSZ-GF71VE MSZ-GF71VE2
Part name
Room temperature
thermistor (RT11)
Indoor coil thermistor
(RT12, RT13)
Indoor fan motor (MF)
Horizontal vane motor
(MV1)
Vertical vane motor
(MV2)
OBH634B
Symptom
Indoor unit and
outdoor unit do
not operate.
Symptom
Outdoor unit
operates but
indoor unit does
not operate.
Check method and criterion
Measure the resistance with a tester.
Refer to 10-7. "Test point diagram and voltage", 1. "Indoor electronic control
P.C. board", for the chart of thermistor.
Check 10-6.
"Check of indoor fan motor".
Measure the resistance between the terminals with a tester.
(Temperature: 10 - 30°C)
Horizontal vane motor (MV1)
Vertical vane motor (MV2)
Condition
The electricity is not conducted to the inter-
lock switch (Fan) of the horizontal vane.
Condition
The operation mode of the each indoor unit
is differently set to COOL (includes DRY) and
HEAT at the same time, the operation mode
of the indoor unit that has operated at fi rst has
the priority.
Color of the lead wire
313 ~ 375 Ω
RED-BLK
268 ~ 322 Ω
25
Remedy
• Refer to 10-6.
"Check of
installation of the horizontal
vane".
Remedy
• Unify the operation mode.
Refer to outdoor unit service
manual.
Figure
BLK
ROTOR
BLK
Normal
RED
BLK
BLK