Page 1
All manuals and user guides at all-guides.com NVISION NV3128 RS-422A Machine-Control Data Routing Switch Instruction Manual Manual Part Number: MN3128-00B...
Page 2
No part of this manual may be reproduced in any form by photostat, microfilm, xerography, or any other means, or incorporated into any information retrieval system, electronic or mechanical, without the written permission of NVISION, Inc. Notice The information contained in this Operations Manual is subject to change without...
Page 3
(2) years, optionally extendable to five (5) years, from the date of shipment from the factory. If warranted equipment fails due to such defects, NVISION, Inc. shall, at its option, repair or provide replacement for the defective part or product.
Page 4
All manuals and user guides at all-guides.com Technical Support If you need support of any kind related to your equipment, contact the local representative who sold you the product, or you may contact NVISION, Inc. directly by any of the following methods. Telephone Main Telephone: (530)-265-1000...
Page 5
The fuse symbol indicates that the fuse referenced in the text must be replaced with one having the ratings indicated. The presence of the UL symbol in or on NVISION equipment means that it has been designed, tested and certified as complying with applicable Underwriters Laboratory (USA) regulations and recommendations.
Page 6
All manuals and user guides at all-guides.com Warnings A warning indicates a possible hazard to personnel which may cause injury or death. Observe the following general warnings when using or working on this equipment. - Heed all warnings on the unit and in the operating instructions. - Do not use this equipment in or near water.
Page 7
All manuals and user guides at all-guides.com Cautions A caution indicates a possible hazard to equipment that could result in equipment damage. Observe the following general cautions when operating or working on this equipment. - When installing this equipment, do not attach the power cord to building surfaces. - To prevent damage to equipment when replacing fuses, locate and correct the problem that caused the fuse to blow before re-applying power.
Page 8
All manuals and user guides at all-guides.com North American Power Supply Cords The power cords supplied with this equipment have a molded grounding plug (NEMA 5-15P) at one end and molded grounding receptacle (IEC 320-C13) at the other end. Conductors are CEE color- coded: Light blue (neutral), Brown (line) and Green or Green/Yellow (ground).
All manuals and user guides at all-guides.com TABLE OF CONTENTS 1. GENERAL INFORMATION ..................1-1 General ....................1-3 Architecture ....................1-4 I/O ......................1-12 Physical ....................1-12 Ancillary Equipment ................1-13 Specifications ..................1-14 2. INSTALLATION ......................2-1 HARDWARE INSTALLATION ..............2-3 CONFIGURATION ..................
Page 10
All manuals and user guides at all-guides.com...
All manuals and user guides at all-guides.com 1.5 ANCILLARY EQUIPMENT 1.6 SYSTEM SPECIFICATIONS NV3128 RS-422A Machine-Control Data Switch 1-13...
Page 24
All manuals and user guides at all-guides.com TABLE 1-1 NV3128 SPECIFICATIONS INPUTS/OUTPUTS PERFORMANCE MECHANICAL ELECTRICAL NV3128 RS-422A Machine-Control Data Switch 1-14...
SONNEL. 2.1 HARDWARE INSTALLATION The following discussion makes frequent reference to Fig 2.1 The NV3128 installs in a 19-inch EIA equipment rack. No fans or cooling are required, but adequate free air space should be maintained around the equipment. 1. Using the 2MM allen key supplied, remove the doors and vanity ear covers from the front of the frames.
Page 28
All manuals and user guides at all-guides.com 8. Connect the AC line cord at the rear of the frame and to the input AC, which powers up the NV3128. Ensure the system powers up correctly. a. LEDs on the Power Supply front panel should glow.
Page 29
All manuals and user guides at all-guides.com FIGURE 2.1 FRAME INSTALLATION NV3128 RS-422A Machine-Control Routing Switch...
The Command Interpreter and the Matrix Control II are obsolete control cards for the NV3128 Router. Some instructions in this section apply only to older systems having these cards. These instructions have been retained for the benefit of customers who own older systems, but they are labeled "(OBSOLETE)"...
Page 31
All manuals and user guides at all-guides.com PARTITION DIP SWITCHES (OBSOLETE) 1. Two banks of dip switches on the Control Interface Module configure the partition information for the NV3128. Bank 1 defines the physical partition, Bank 2 enables the ghost partition and defines its controller level.
Page 32
00001 = level 1 where 0 denotes an OFF bit and 1 denotes an ON bit. 10001 = level 17. The range is from 0-31. Some control protocols define levels alphabetically, in which case 0=A and 25=Z. NV3128 RS-422A Machine-Control Routing Switch...
Page 33
The length of the partition is the number in the switch times 32. For the NV3128, the number is 0100 (128). For a 64 port version of the switch, the number is 0010. No other configuration is valid for a data switch.
Page 34
2.2.4 CONFIGURING THE SERIAL INTERFACE (OBSOLETE) 2.2.4.1 JUMPER SETTINGS (OBSOLETE) The serial data interface between the control system and the NV3128 can be either RS-422A or RS-232. For the newer Universal Control module, the serial interface ports are set up using UniDiag. For the older Command Interpreter, jumpers on the Command Interface Module select parameters appropriate to the chosen protocol.
Page 35
All manuals and user guides at all-guides.com 2.2.5 PARALLEL INTERFACE (OBSOLETE) Newer NV3128 frames do not include a parallel interface. The older NV3128 frames with the Command Interpreter card included a parallel connector which could be used with the Pesa parallel interface. Because the Universal Control card does not support the parallel interface, older frames that have the Universal Control card cannot make use of the parallel interface connector.
Page 36
1-2* RI (pin 9) * = DEFAULT CONFIGURATION Two final jumpers,J500 and J700 , enable or disable the diagnostic output: DIAGNOSTICS ENABLE/DISABLE (OBSOLETE) JUMPER ENABLED DISABLED J500 1-2* J700 1-2* * = DEFAULT CONFIGURATION NV3128 RS-422A Machine-Control Routing Switch 2-12...
Page 37
All manuals and user guides at all-guides.com 2.2.7 CONFIGURING THE REFERENCE INPUT The NV3128 can derive its timing from a Video Reference input, or it can free run. The reference input is normally a video black burst signal, but optionally can be an AES/EBU digital audio bitstream.
2.3 CABLING THE NV3128 Figures 2-2 and 2-3 at the end of this section show the rear panel connections on the NV3128. Notice that there are old and new frames corresponding to the old Command Interpreter and the new Universal Control Card.
Page 39
Frame Ground Frame Ground Receive A Transmit A Transmit B Receive B Transmit Common Receive Common Spare Spare Receive Common Transmit Common Receive B Transmit B Transmit A Receive A Frame Ground Frame Ground NV3128 RS-422A Machine-Control Routing Switch 2-15...
Page 40
All manuals and user guides at all-guides.com RS232 (OBSOLETE): The NV3128 Control/Command Interpreter interface is always a DCE device when operating in RS-422A mode. As shown above, the system can be configured as either DTE or DCE equipment in RS-232 mode.
Page 41
1. Configure the Control Interface Module as a DCE. 2. Connect the Control Interface Module and the controlling device using a 9-pin to 9-pin (male to female) cable, connected straight through ( no exchange of pins). NV3128 RS-422A Machine-Control Routing Switch 2-17...
2.5 IMPLEMENTING HOT CHANGEOVER (OBSOLETE) Relay terminals on the rear panel of the NV3128 provide control of the NV3128 should a hot changeover system be required. Call NVision Technical Support as listed in Chapter 5 of this manual for instructions in implementing this feature.
UniDiag manual. CABLING COMPLETE You are now finished making cable connections to the NV3128 Router. The remainder of this section explains how to install NVUtils for use in configuring routers that have the old Command Interpreter module.
Page 44
All manuals and user guides at all-guides.com CONTROL SYSTEM CONNECTORS UNIDIAG REAR CONNECTOR VIDEO REF INPUTS 1 & 2 MACHINE CONTROL CONNECTORS 1 - 128 FIG 2-2. REAR CONNECTIONS (NEW FRAME) NV3128 RS-422A Machine-Control Routing Switch 2-20...
Page 45
All manuals and user guides at all-guides.com FIG 2-2. REAR CONNECTIONS (OLD FRAME) FIG 2-3. REAR CONNECTIONS (OLD FRAME) NV3128 RS-422A Machine-Control Routing Switch 2-21...
Page 46
UniDiag manual. GENERAL NVUtils is a collection of PC compatible computer programs that provide diagnostics and control of the NVision family of digital routing switches. The utilities currently consist of two programs, NVTake and NVMap. Both programs communicate with the router...
Page 47
C:> CD NVUtils C:> COPY A:*.* C:> CD \COMMANDS C:> EDIT NVTAKE.BAT :========================= :SAMPLE NVTake.BAT | :========================= CD \NVUtils NVTAKE V 1 38400 C:> EDIT NVMap.BAT :========================= :SAMPLE NVMap.BAT | :========================= CD \NVUtils NVTAKE V NV3128 RS-422A Machine-Control Routing Switch 2-23...
Page 48
Interface. · NVMap communicates with the diagnostic data port J400, located on the front of the Command Interface Module. · NVTake communicates with the RS422/RS232 Command Data Port at the rear of the frame. NV3128 RS-422A Machine-Control Routing Switch 2-24...
All manuals and user guides at all-guides.com CHAPTER 3 - OPERATIONS 3.1 CONNECTION NOTES NV3128 RS-422A Machine Control Data Routing Switch...
Page 52
All manuals and user guides at all-guides.com 3.1.1 POINT-TO-POINT CONNECTION RULES: 3.1.2 MULTIDROP CONNECTION RULES NV3128 RS-422A Machine Control Data Routing Switch...
The following information applies only to older systems with the Command Interpreter module. Newer systems with the Universal Control module use UniDiag instead of the NVUtils described below. See the UniDiag manual for details. NVTAKE NVMAP NV3128 RS-422A Machine Control Data Routing Switch...
Page 54
All manuals and user guides at all-guides.com 3.2.1 OPERATING INSTRUCTIONS - NVTAKE (OBSOLETE) INVOCATION: NVTAKE [H | U | V | E | R] [1|2] [9600|38400] OPERATIONS CHANGE ROUTER LEVEL NV3128 RS-422A Machine Control Data Routing Switch...
Page 55
All manuals and user guides at all-guides.com SENDING A SINGLE TAKE EXAMPLE: SOURCE ADDRESS DESTINATION ADDRESS 3 NV3128 RS-422A Machine Control Data Routing Switch...
Page 56
All manuals and user guides at all-guides.com F9 - BUILD A SALVO TABLE NV3128 RS-422A Machine Control Data Routing Switch...
Page 57
All manuals and user guides at all-guides.com F10 - LOAD A SALVO FROM DISK F2 - SEND A SALVO NV3128 RS-422A Machine Control Data Routing Switch...
Page 58
All manuals and user guides at all-guides.com QUERYING SYSTEM CONNECTIONS (VISTEK PROTOCOL ONLY) F4 - QUERY A SINGLE CROSSPOINT F5 - QUERY MULTIPLE CONNECTIONS F6 - LIST DESTINATIONS CONNECTED TO A SOURCE NV3128 RS-422A Machine Control Data Routing Switch 3-10...
Page 59
All manuals and user guides at all-guides.com 3.2.2 OPERATING INSTRUCTIONS - NVMAP (OBSOLETE) INVOCATION: NVMAP [H | U | V | E | R] [1|2] OPERATION: NV3128 RS-422A Machine Control Data Routing Switch 3-11...
Page 60
All manuals and user guides at all-guides.com NV3128 RS-422A Machine Control Data Routing Switch 3-12...
Page 61
All manuals and user guides at all-guides.com Screen I (F2) · · · NV3128 RS-422A Machine Control Data Routing Switch 3-13...
Page 62
All manuals and user guides at all-guides.com Screen II · · · · SpaceBar Enter · · NV3128 RS-422A Machine Control Data Routing Switch 3-14...
The controlling port will be associated with the source or destination parameter, depending on the configuration of Reverse Src/Dest. See the explanation of Reverse Src/Dest in the UniDiag manual for details. NV3128 RS-422A Machine-Control Data Routing Switch...
Page 66
All manuals and user guides at all-guides.com NV3128 RS-422A Machine-Control Data Routing Switch...
4.2 CIRCUIT OPERATION The following discussion provides an overview of circuit operation for each of the circuit boards in the NV3128 Router frame. Because repair is done by replacing modules rather than repairing them, schematics and bills of material are not provided but may be requested from NVISION Technical Support.
Page 68
I/O modules by 16 octal buffer/line-driver integrated circuits. MISC: A submodule and associated circuitry process raw DC from the power supply to produce a carefully regulated and current limited +5VDC for distribution across the module. NV3128 RS-422A Machine-Control Data Routing Switch...
Page 69
Submodules each operate separately on the raw DC input voltage to provide +5VDC operating levels for 1/2 the available circuits. By thus dividing the circuitry, the impact block of a failure is correspondingly reduced. NV3128 RS-422A Machine-Control Data Routing Switch...
Page 70
Further, the assembly contains all circuitry required to configure the NV3128, and produces master timing signals for the system. MAPPING At the heart of the module are the microprocessors that govern circuit operation.
Page 71
NV3128, this oscillator free runs. PARTITIONING On the Command Interpreter two banks of DIP switches and their associated circuitry configure the NV3128 into partitions. Additionally, software versions supporting various controllers may make use of these switches for supplementary configuration control.
Page 72
All manuals and user guides at all-guides.com 4.2.5 POWER SUPPLY ASSY: PS2001-XX The NV3128 Frame and its Power Supply are UL listed. The Power Supply Module PS2001-01 powers the NV3128 from the AC line at a nominal voltage of 115 VAC - 60 Hz or 230 VAC - 50Hz. The power...
Page 73
A boot-strap multivibrator circuit on the submodule initializes the power-supply circuitry. Although each of the NV3128 modules has its own on-board voltage regulators and current limiters, the power supply itself is self limiting. Transformer T2 monitors the primary current and steps it down to a level where it can safely drive the PWM submodule, shutting it down completely in case of excessive load.
Page 74
All manuals and user guides at all-guides.com NV3128 RS-422A Machine-Control Data Routing Switch 4-12...
Page 75
All manuals and user guides at all-guides.com CHAPTER 5: MAINTENANCE AND TROUBLESHOOTING NV3128 RS-422A Machine Control Data Routing Switch...
Page 76
All manuals and user guides at all-guides.com NV3128 RS-422A Machine Control Data Routing Switch...
Technical Support at the front of this manual. 5.2 SCHEDULED MAINTENANCE The NV3128 requires no periodic maintenance. It is recommended to check the front panel LEDs on each of the cards periodically to ensure that they are operating properly.
All manuals and user guides at all-guides.com 5.4 TROUBLESHOOTING Certain features of the NV3128 facilitate troubleshooting the router. · Power supplies and all active modules can be removed and re-inserted live without damage. · Since mapping of the crosspoint modules takes place continuously, a crosspoint card removed and re-inserted will be updated within a few cycles of video vertical retrace.
Page 79
Most switch problems result from the complexity of the control system interface. Refer to section 3 (older systems) or the UniDiag manual (newer systems) for a discussion of the PC-based diagnostic and control utilities furnished with the routing switch. NV3128 RS-422A Machine Control Data Routing Switch...
Page 80
All manuals and user guides at all-guides.com NV3128 RS-422A Machine Control Data Routing Switch...
All manuals and user guides at all-guides.com GLOSSARY NV3128 RS-422A Machine-Control Data Routing Switch...
Page 82
All manuals and user guides at all-guides.com NV3128 RS-422A Machine-Control Data Routing Switch...
Page 83
Hybrid ..........Electrical component technology I/O ............. Commonly used abbreviation for Input and Out interfaces and/or modules IC ............Commonly used abbreviation for Integrated Circuit LED ..........Light Emmitting Diode Monaural ......... Single audio channel NV3128 RS-422A Machine-Control Data Routing Switch...
Page 84
Synchronization ......The process whereby two machines are controlled by identical time bases Take ..........A connection command given to a signal routing device Timecode ........Standard for encoding time in hours, minutes, seconds and frames of video TTL ..........Transistor, Transistor Logic NV3128 RS-422A Machine-Control Data Routing Switch...
Page 85
All manuals and user guides at all-guides.com VCXO ..........Voltage Controlled Crystal Oscillator VDE ..........Verband Deutscher Electrotechniker Video ..........Picture element of a television signal VTR ..........Commonly used abbreviation for Video Tape Recorder NV3128 RS-422A Machine-Control Data Routing Switch...
Page 86
All manuals and user guides at all-guides.com NV3128 RS-422A Machine-Control Data Routing Switch...
Need help?
Do you have a question about the NV3128 and is the answer not in the manual?
Questions and answers