Page 1
Keypad Access Cylindrical Lock ™ Touchscreen and Push Button Installation and Programming Instructions 3/32" Optional Optional Retrofitting or modifying this product may impact fire rating, safety features and warranty. Consult with code specifications to ensure compliance with all codes and ratings.
Page 2
Determine Handing The hand of a door is determined from the secure side of the door. The term "secure" means the side from which you initially unlock and enter. Left Hand “LH”, Hinges Left. Left Hand Reverse "LHR", Hinges Left. Open Inward.
Prepare Door DPS Option Wood Door: 3/8" Dia. Thru to Hole in Door Face *Metal Door: 3/4" Dia. Thru to Hole in Door Face Drill holes 1/2 way thru door then complete from other side to prevent splitting. *Metal Door Installations Supplied plastic collar MUST be installed for DPS to function properly.
Page 4
Prepare Frame DPS Option 7-16 / 8-32 x 1" UNCWS Frame Wood Frame: 3/8" Dia. x 1" *Metal Frame: 3/4" Dia. x 1" See Instruction Frame A7983B Inside 3-1/2" of Door 1" Dia. x 1/2" Deep *Metal Door Installations Supplied plastic collar MUST be installed for DPS to function properly.
Page 5
Prepare Inside Lock Do not take apart the keypad. 80-9150-0080-010 11-21 Part of ASSA ABLOY...
Install Latchbolt 2-3/8" Latchbolt for thin doors sold separately. See Installation Options. 7-16 / 8-32 x 1" UNCWS Inside of Door Curved edge of latchbolt faces direction door closes. Remove Battery Cover 80-9150-0080-010 11-21 Part of ASSA ABLOY...
Page 7
Install Keypad Thin door gaskets sold separately. See Installation Options. Inside of Door Optional DPS Inside of Door Two moving "T" tabs must be fully captured in retractor pocket. Mounting Flanges must be in Mounting Flange Pockets. View from Outside of Door Mounting Flange Mounting Flange Pocket "T"...
Page 8
Install Inside Support 10-32 x 2-1/2" PFHMS Inside of Door Optional DPS Do Not Overtighten Screws 80-9150-0080-010 11-21 Part of ASSA ABLOY...
Page 9
Attach Cables to Inside Lock Keypad Connection Optional Motor Connection Connection 80-9150-0080-010 11-21 Part of ASSA ABLOY...
Page 10
Install Inside Lock Thin door gaskets sold separately. See Installation Options. Avoid Crimping Cables Test Inside Lever Operation 80-9150-0080-010 11-21 Part of ASSA ABLOY...
Page 11
Install Batteries & Cover "Welcome to Yale." Optional Network or Yale Accentra Key module must be installed BEFORE batteries. See Installation Options. Congratulations, you've installed the Yale nexTouch™ Cylindrical Lock! 80-9150-0080-010 11-21 Part of ASSA ABLOY...
Adjusting for 1-3/8" Door (if necessary) Order 1-3/8" Thin Door Kit: 14-4761-0106 CAUTION: Cylinders furnished with nexTouch™ lock for use in 1-3/8" doors have a tailpiece that is 1/4" shorter than the standard cylinders that are furnished for 1-3/4" doors.
Page 14
Creating Master PIN Code Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. Activate Lock "Register Master Code.
Page 15
Creating User PIN Codes Master PIN code must be created first. *Max User Codes = 500 The Yale Accentra Key module enables access with physical (cards and fobs) and mobile credentials ONLY. Creation and use of User PIN codes are disabled. Enter Master Activate Lock PIN code...
Page 16
Creating User PIN Codes con't Enter 4-8 digit PIN code followed by "Registered. Press the check key to complete. Press the gear key to continue." Adding more User Codes: To end programming: Press Press Enter 4-8 digit PIN code "Completed." Press "Registered.
Page 17
Locking & Unlocking Door with Registered Master or User PIN Code The Yale Accentra Key module enables access with physical (cards and fobs) and mobile credentials ONLY. Creation and use of User PIN codes are disabled. Master PIN code is only used for programming and configuring lock with Yale Accentra Multi-Family configuration app and will not unlock door.
Page 18
Testing Outside Lever Operation Locking Door with Privacy Button 80-9150-0080-010 11-21 Part of ASSA ABLOY...
Resetting Lock to Factory Default Reset Button Inside Lock Lever Removal Tool Hex Wrench When lock is reset to factory defaults all PIN codes (including the Master PIN code*) are deleted and all programming features are reset to original default settings (see Factory Settings). IMPORTANT: The Reset Button is located on Inside Lock.
Page 20
Definitions All Code Lockout Mode: This feature is enabled by the Master PIN code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while unit is in Lockout, there will be an audible lock response. The touchscreen keypad will display a RED locked padlock. (Main Menu selection #6.) Automatic Re-lock Time: After a successful unlock, unit will re-lock automatically after 3 seconds or for a duration selected in Advanced Lock Settings (Main Menu selection #3 then #1).
Feature Programming Through Menu Mode Using Master PIN code* 1. Activate the lock. 2. Enter 4-8 digit master PIN code* followed by key. Lock Response: "Menu mode, enter number (Enter digit corresponding to the function to be performed), press the key to continue."...
Programming Troubleshooting Symptom Suggested Action Touchscreen models become active by pressing Yale logo or key or by touching keypad with whole hand. Lock does not respond. Push Button models become active when any key is pressed. • Check batteries are installed and oriented correctly (polarity). There are no lights or •...
Hardware Troubleshooting Cycle lock in both the locked and unlocked positions. If problems are found: Door is binding. a. Check that door and frame are properly aligned and door is free swinging. b. Check hinges: They should not be loose or have excessive wear on knuckles. Latchbolt will not deadlock.
Page 24
FCC: Industry Canada: This device complies with part 15 of the FCC Rules. Operation This device contains licence-exempt transmitter(s)/receiver(s) is subject to the following two conditions: (1) This device may that comply with Innovation, Science and Economic not cause harmful interference, and (2) this device must Development Canada’s licence-exempt RSS(s).