Page 3
....30-31 ....32-37 Indications of use General Description General Description Troubleshooting Stimulator Specifications Legend Indicators Installation and Registration Contact with Fesia Support Sensor Specifications Simbol Initial Checks Main Menu Electrode Specifications Device Placement Habituation Protocol Charger Specifications Removal of the Device...
Fesia Walk is a rehabilitation device designed to provide dorsal and plantar ankle flexion for people suffering from foot drop/ presence of lesions and/or wounds of any kind The system should not be used if there is (skin, muscle, tendon, bone...) in the...
Page 6
Indicates low battery (red light) Indicates that the stimulation is active (yellow light) Indicates the intensity increase button Indicates the intensity reduction button Indicates the button on/off system INSTRUCTIONS FOR USE | Fesia Walk 11 10 INSTRUCTIONS FOR USE | Fesia Walk...
It is a charger approved for charging medical devices. The splitter allows the simultaneous charge of both stimulator and sensor. Check the Fesia Walk transport case and make sure that all the components are included. INSTRUCTIONS FOR USE | Fesia Walk 15...
Page 9
“Beep”. Pulse sound S�mula�on Off Reduce intensity bu�on Bluetooth indicator S�mulator connected to Fesia Pro App S�mulator Off Ba�ery indicator Low ba�ery level INSTRUCTIONS FOR USE | Fesia Walk 17 16 INSTRUCTIONS FOR USE | Fesia Walk Appropriate batery level...
If there is presence of oils or lotions on the skin, then wipe it off with soap and water. - Always check for redness or rashes on the skin when placed or removed Fesia Walk device. - Be sure to replace the electrodes at least every 15 sessions, even if they appear - Use only the charger and charging ca- ble supplied and/or approved by Fesia.
SWITCH ON THE TABLET AND CONNECT TO THE APP Once all the components are properly placed and turned on, open the Fesia Pro app and search the device serial number to connect it by Bluetooth. You can find the information regarding Fesia Pro app in chapter 3.
Page 12
LEDs will turn off. disposed separately from household waste. There are separate collection systems for recycling in the EU. 22 INSTRUCTIONS FOR USE | Fesia Walk INSTRUCTIONS FOR USE | Fesia Walk 23...
GENERAL DESCRIPTION INSTALLATION AND REGISTRATION It is not required to read this section if you have received a pre-configured tablet by Fesia. The device on which the application is installed must meet It is important to ensure not to use the application more...
Page 15
Click on the "+" icon to create a patient. Fill in the profile details. The mandatory fields are indicated with an asterisk. Delete patient By clicking on the "Delete" icon, all patient data and sessions are deleted. INSTRUCTIONS FOR USE | Fesia Walk 29 28 INSTRUCTIONS FOR USE | Fesia Walk...
Page 16
In the “Session Report” menu, you can see: the report of each session, session's notes and video recordings. The session data can be exported to an excel by clicking on the “Export” button. INSTRUCTIONS FOR USE | Fesia Walk 31 30 INSTRUCTIONS FOR USE | Fesia Walk...
Page 17
By clicking on "Movements configuration" it is possible to access the sponse. movements configuration screens. INSTRUCTIONS FOR USE | Fesia Walk 33 32 INSTRUCTIONS FOR USE | Fesia Walk...
Page 18
Intensity/motor treshold motor threshold into account. Clicking on the "Set Motor Treshold" button, the intensity value will be saved Set motor treshold and later in the movement configuration screen will be possible to upload. 34 INSTRUCTIONS FOR USE | Fesia Walk...
Page 19
- An undefined duration clicking on the "Loop" button (the counter will start groups. from 0). Area stimulation The pads activated by the us- ers are activated. 36 INSTRUCTIONS FOR USE | Fesia Walk INSTRUCTIONS FOR USE | Fesia Walk 37...
Page 20
To do this, the cathodes must be selected one by one Current in the virtual electrode. Current configuration values. It will always change to this state. INSTRUCTIONS FOR USE | Fesia Walk 39 38 INSTRUCTIONS FOR USE | Fesia Walk...
Page 21
Edit intensity Play Edit the relative intensity if Press "Play" to start the sti- desired. mulation. Remember that the relative intensity is being increased over the intensity value set in the pre- vious screen. 40 INSTRUCTIONS FOR USE | Fesia Walk...
Make sure you have checked the following steps before contacting Fesia: Check that you do not have any pending update of the Fesia Pro app (Google Play Store, Select Once you have taken the previous steps, if your problem is not already solved, you can "Menu", "Apps and games").
Pulse Width 150us -. 300 us, resolution of 10us Pulse Frequency 1 - 40Hz resolution of 1 Hz Maximum Output Voltage 180V Maximum Output Frequency 1KHz INSTRUCTIONS FOR USE | Fesia Walk 49 48 INSTRUCTIONS FOR USE | Fesia Walk...
Optimum temperature for long-term storage: 5°C to 27°C Class II Protection Recommended storage time: 3 months (sealed) Expiration time: 3 years (sealed) Relative humidity: 35% to 50% Atmospheric pressure: 700hPa to 1060hPa INSTRUCTIONS FOR USE | Fesia Walk 51 50 INSTRUCTIONS FOR USE | Fesia Walk...
GUIDANCE AND MANUFACTURER'S DECLARATION - ELECTROMAGNETIC IMMUNITY EMI TABLES The Fesia Walk device is intended for use in the electromagnetic environment specified below. The customer or user of this device should assure that it is used in such an environment.
Page 28
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above, the Fesia Walk device should be observed to verify normal operation.