    TABLE OF CONTENTS About Support Features Laser Safety Compatible Devices Installation & Removal Installing the App Pairing LED Indicator Surface & Internal Temp Troubleshooting Scanning Barcodes Accuracy Check Cleaning Reset Procedure Distance to Spot Technical Specs IP Rating Warranty Certifications FCC Compliance IC Warning USER...
  • Page 3: About

    ABOUT Scancase is an ultra-smart case that turns your phone into a powerful all-in-one device for infrared and probe temperature taking and barcode scanning. Scancase’s probe arm is compatible with standard K-type thermocouple connector probes. An internal battery charged with...
  • Page 4: Support

    Support area from the main menu of any ZippyYum app. CONTACT US To reach our support team, please use the Help & Support area from the main menu of any ZippyYum app. You can also email us at support@zippyyum.com or live chat with us on our website.
  • Page 5: Features

    FEATURES Rotating arm Barcode scanner Laser indicator LED indicator Infrared sensor Reset button K-type thermocouple probe jack USB-C charging port USER MANUAL...
  • Page 6: Laser Safety

    LASER SAFETY The ZippyYum Scancase contains a laser compliant with FDA 21 CFR 1040.10, subchapter J. Refer to the technical specifications for additional details. Every device is tested for compliance with Class II laser power limitation. WARNING! The laser is activated whenever taking an infrared temperature.
  • Page 7: Compatible Devices

    COMPATIBLE DEVICES Scancase models ZYGS003 and ZYGS003-M are compatible with the iPhone SE, iPhone 8, and iPhone 7. iPhone SE iPhone 8 iPhone 7 Scancase models ZYGS004 and ZYGS004-M are compatible with the UMIDIGI A3X Android phone only. UMIDIGI A3X See page 41 for iPhone and Android device FCC and IC ID information.
  • Page 8 SETUP...
  • Page 9: Installation & Removal

    INSTALLATION & REMOVAL Scancase may be shipped with or without a phone pre-installed. You can install or remove a compatible phone by following these steps. Use the included screwdriver to unscrew the 2 screws located on the lower, rear panel of the case.
  • Page 10 INSTALLATION & REMOVAL Next, slide the bottom part of Scancase down gently to separate it from the top section of the case. Slide down USER MANUAL...
  • Page 11 INSTALLATION & REMOVAL If removing a phone, gently unplug the connector then slide the phone out of Scancase. If installing an phone, slide it into Scancase and gently plug Scancase’s connector into your phone. Plug USER MANUAL...
  • Page 12: Installing The App

    INSTALLING THE APP Your ZippyYum Scancase must be paired with the GoVentory or GoTemp app on an iOS or Android device before being used. To install the app(s), tap below or visit: www.zippyyum.com/apps TAP TO INSTALL Once the GoVentory or GoTemp app is installed, log into the app using your login credentials.
  • Page 13: Pairing

    PAIRING PRO TIP Your scancase’s unique identifier, also known as its MAC address, is printed on the back of the device as shown below. You may need it during pairing. MAC address USER MANUAL...
  • Page 14 PAIRING The GoVentory and GoTemp apps will automatically connect to your scancase if only one scancase is detected. If there are multiple cases, you’ll see a list of options. Available scancases will show as “SCANCASE_##” with ## being the last two digits of its MAC address.
  • Page 15: Led Indicator

    LED INDICATOR Scancase has an LED indicator to show battery information and pairing connectivity status to its iOS device. INDICATOR OFF Power off, sleep mode, or dead battery RED LED Battery critically low, should be charged ORANGE LED Battery charging,...
  • Page 16 TAKING TEMPS...
  • Page 17: Surface & Internal Temp

    When internal temperatures are more critical for items like meat cooking on a grill, use Scancase’s built-in probe to take an internal probe temperature. Cold Holding Example: Use your free, gloved hand to mix or move...
  • Page 18: Troubleshooting

    When contacting ZippyYum support be prepared to identify why you beleive Scancase is not functioning (like using another thermometer to verify the temperature, etc.) USER MANUAL...
  • Page 19 (like a label). When a sudden change of temperature occurs (like walking into a freezer), Scancase may need to be preconditioned for up to 15 minutes for accurate temperatures. Avoid angling Scancase for infrared temperatures.
  • Page 20 SCANNING BARCODES...
  • Page 21: Scanning Barcodes

    SCANNING BARCODES Scancase emits a laser to indicate where it is scanning. Make sure the laser completely crosses through the entire barcode for proper scanning. Scancase cannot be submerged during scanning. For best results, keep Scancase between 2” to 5” (5 cm to 12 cm) away from the barcode while scanning.
  • Page 22 SERVICE & CLEANING...
  • Page 23: Accuracy Check

    Scancase should read about 32.0°F or 0°C. If Scancase is more than 4°F or 2°C out-of-range, please contact ZippyYum support. USER MANUAL...
  • Page 24 Using a probe- based thermometer will produce different results and should not be used to check Scancase’s IR accuracy. COMPLETE ACCURACY CHECK For a more detailed accuracy check procedure for both hot and cold temperatures, please visit the ZippyYum knowledge base.
  • Page 25: Cleaning

    WARNING! Do not submerge Scancase or wash in a dishwasher. To clean the barcode scanner or body of Scancase, moisten a cloth with a water-based mild detergent and wipe the device. USER MANUAL...
  • Page 26 CLEANING A dirty infrared lens is the most common cause of inaccurate infrared temperatures. To clean the infrared lens, lightly moisten a cotton swab with water and insert and swirl it in the lens opening to clean any debris. Repeat with a clean cotton swab until it comes out clean.
  • Page 27: Reset Procedure

    RESET PROCEDURE To reset Scancase, use a thin pin like a paperclip to press the reset button located on the top area on the front of Scancase. Scancase will blink orange 5 times to confirm the reset. Reset buton USER...
  • Page 28: Distance To Spot

    The field of view (distance- to-spot) is the area where temperature is being measured via infrared. The distance you hold Scancase away from the product determines the dimensions of this area. The further away from the product, the larger the area being measured.
  • Page 29 TECHNICAL SPECS...
  • Page 30: Technical Specs

    TECHNICAL SPECS Storage Temp 14°F to 113°F -10°C to 45°C Operating Temp 50°F to 104°F 10°C to 40°C Humidity 10% to 90% Charging Current RH ≤1,000mA MODELS: ZYGS003, ZYGS003-M RH ≤1,500mA MODELS: ZYGS004, ZYGS004-M Charging Voltage Bluetooth Power <0 dBM Capacity 2,000 mAH MODELS: ZYGS003, ZYGS003-M...
  • Page 31 TECHNICAL SPECS Temperature Unit °F and °C IR Measurement -94°F to 716°F Range -70°C to 380°C Probe -454°F to 2500°F Measurement -270°C to 1372°C Range Actual probe measurement may be limited by the range of the probe. Please refer to your probe’s documentation prior to use.
  • Page 32 TECHNICAL SPECS IR Accuracy ±2°F or ±1°C at Room Temp when object is (77°F or 25°C) 32°F to 140°F ±4°F or ±2°C when object is <32°F or >140°F IR Emissivity 0.95 (preset, but adjustable) IR Measurement 1” to 12” Distance 2.5 cm to 30cm Distance-to-Spot 12:1...
  • Page 33 TECHNICAL SPECS Incline Angle Up to 65° Pitch Angle Up to 60° Depth of Field 60 to 200 mm Code 128 10 Mil 18 bytes Paper Code Depth of Field 60 to 200 mm Code 128 18 bytes Phone Code Depth of Field QR 40 to 120 mm 10 mil 160 bytes...
  • Page 34: Ip Rating

    IP RATING Scancase is rated IP67 (maximum depth of 1 meter up to 30 minutes) under IEC standard 60529. This rating is for the Scancase case only. Please refer to the owner’s manual for your compatible iOS device for its waterproof rating.
  • Page 35 WARRANTY & LEGAL...
  • Page 36 WARRANTY ZippyYum warrants Scancase, at the time of its sale by ZippyYum, is free of defects in material, workmanship, and component failures under normal and proper use for a period of one (1) year from date of delivery. This warranty applies worldwide.
  • Page 37: Warranty

    ZippyYum’s liability on any claim for damages arising in connection with the manufacture, sale, installation, delivery, or use of Scancase shall never exceed the purchase price of the product. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort, or otherwise.
  • Page 38: Certifications

    CERTIFICATIONS Scancase conforms to the following standards: UL LISTED FOR UL2333 Infrared Thermometers - E1481655 UL EPH CLASSIFIED FOR ANSI/NSF 2 Food Service Equipment - SA44549 FCC CFR47 PART 15 SECTION 15.247:2014 FCC ID: GU6ZYGS003 (iOS), GU6ZYGS004 (Android) INDUSTRY CANADA RSS-247...
  • Page 39: Fcc Compliance

    FCC COMPLIANCE This device complies with Part 15 of the FCC rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 40: Ic Warning

    IC WARNING This device complies with Industry Canada license- exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device.
  • Page 41 OTHER The following device models are compatible with Scancase: iPhone SE FCC ID IC ID A2275 BCG-E3500A 579C-E3500A A2296 BCG-E3501A 579C-E3501A A2297 BCG-E3500A 579C-E3500A A2298 BCG-E3500A 579C-E3500A iPhone 8 FCC-ID IC-ID A1863 BCG-E3159A 579C-E3159A A1905 BCG-E3172A 579C-E3172A A1906 BCG-E3171A 579C-E3171A...

This manual is also suitable for:

Zygs004Zygs004-m

Table of Contents