NOTE – the Main Unit ships with the carrier frequency DEFAULT setting of
38 KHz for all six sources.
*********************************************************************************
COMMAND:
*IRSETDF<CR> – Restores DEFAULT SOURCE IR carrier frequency settings
(38 KHz for all six sources).
RESPONSE: Same response as for #IRSETSR<CR>
*********************************************************************************
COMMAND: *SxIR56SET<CR> - sets SOURCE x to 56 KHz IR repeat carrier (x is 1 to 6).
RESPONSE: Same response as for #IRSETSR<CR>
*********************************************************************************
COMMAND: *SxIR38SET<CR> - sets SOURCE x to 38 KHz IR repeat carrier (x is 1 to 6).
RESPONSE: Same response as for #IRSETSR<CR>
*********************************************************************************
COMMAND/RESPONSE DESCRIPTIONS.
NOTE – zone number field xx should ALWAYS
Include a lead zero ("0") for zone numbers less than 10.
COMMAND:
*ZxxCONSR<CR> - Connect STATUS REQUEST where xx is zone # from 1 to
RESPONSE:
#ZxxPWRppp,SRCs,GRPt,VOL-yy<CR>
This response will also be issued in response to pressing the ON/OFF, VOLUME, or SOURCE
keys on a KEYPAD. NOTE – the response will be issued if a SOURCE key is press`ed on a
zone that is powered OFF even though the key press has no effect on the system. It will be
output at every increment during a volume ramp initiated by HOLDING a VOLUME UP or
VOLUME DOWN key on a keypad. It will also be issued at every increment of a volume
ramp commanded by the *ZxxVOL+<CR> and *ZxxVOL-<CR> commands (see below).
The MUTE value will be asserted if a *ZxMTON<CR> command has been received, OR if the
volume is run all the way to the lowest possible point (volume off). An active EXTERNAL
MUTE input, however, will always override other volume response values with the "XM"
response.
*********************************************************************************
COMMAND:
*ZxxSETSR<CR> – ZoneSet STATUS REQUEST where xx is zone # from 1 to
12.
RESPONSE:
#ZxxORp,BASSyy,TREByy,GRPq,VRSTr
12.
-yy = level below max in dB: -00 to -79 dB
-yy = "MT" if in MUTE state
-yy = "XM" if external MUTE is being held
2
-ppp = "ON" (2 characters)
or "OFF" (3 characters)
-s = SOURCE NUMBER 1 to 6
-q = 0 if SOURCE GROUP is ON
1 if SOURCE GROUP is OFF
(include lead 0 for all single-digit values)
active
-p = 1 if DIP switches are
overridden*
0 if DIP switches are in control