Application: Replacement of the Refractory Target on the E-Classic 1400 and 2300 models.
These instructions outline the procedure for installing the Refractory Target on the
E-Classic 1400 and 2300 models. Read and understand these installation instructions
before beginning the installation. Make sure all parts and tools are accounted for.
These procedures should be performed by a qualified individual and in accordance with
any and all federal, state/provincial and local codes and regulations. When performing
work on an appliance observe all precautions in the literature, tags and labels attached to
the appliance and other safety precautions that may apply. When working with electricity
and electrical components, failure to follow precautions could result in property damage,
personal injury or death.

Kit Contents:

p/n
Qty.
4050009
1 Refractory Target

You Will Need to Supply:

Standard Hand Tools
Do not attempt installation of this kit without first disconnecting the electrical power at
the main power source and turning off the gas supply at the appliance service valve.
Remove all wood and live coals from the outdoor furnace and allow the firebox to cool
thoroughly. Do not perform this installation with any live coals in the outdoor furnace.
1. Disconnect the electrical power to the
outdoor furnace at the main power source;
then turn off the gas supply at the appliance
service valve.

Refractory Target Kit

Kit p/n 2500037 (ECL 1400), 2500038 (ECL 2300)
Installation Instructions
Description
E-Classic 1400
(in Kit p/n 2500037)
WARNING
p/n
4050010
9000146
CAUTION
2. Remove all wood and live coals from the
outdoor furnace and allow the firebox to
cool thoroughly.
- 1 -
Qty.
Description
1 Refractory Target
E-Classic 2300
(in Kit p/n 2500038)
Instructions p/n 9000146
5/14/2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECL 1400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Central Boiler ECL 1400

  • Page 1 Refractory Target Kit Kit p/n 2500037 (ECL 1400), 2500038 (ECL 2300) Installation Instructions Application: Replacement of the Refractory Target on the E-Classic 1400 and 2300 models. These instructions outline the procedure for installing the Refractory Target on the E-Classic 1400 and 2300 models. Read and understand these installation instructions before beginning the installation.
  • Page 2 3. Remove all ashes from the firebox and Reaction Chamber. Fig. 2 Fig. 1 4. Remove the grate bars, refractory panels, and the refractory target from the outdoor furnace as shown in Fig. 1 and discard. NOTE: Fig. 1 is for illustration purposes only.

This manual is also suitable for:

Ecl 230025000372500038

Table of Contents