The Start Bar is an ergonomic starting system. The internal anti-tiedown control
monitors both start sensors for concurrent operation. The output utilizes
redundant positive guided relays which are monitored to ensure proper
operation.
TB-2 Series
TB-2E
Two-Hand Start Bar
Anti-Tiedown Switch Monitor
Owner's Manual
This product meets the OSHA 1910.217(b)(13) definition of "Control
Reliability ".
TB-2M
TB-2W

Advertisement

loading

Summary of Contents for Nolatron TB-2 Series

  • Page 1 TB-2 Series TB-2E TB-2M TB-2W Two-Hand Start Bar Anti-Tiedown Switch Monitor Owner's Manual The Start Bar is an ergonomic starting system. The internal anti-tiedown control monitors both start sensors for concurrent operation. The output utilizes redundant positive guided relays which are monitored to ensure proper operation.
  • Page 3 The Nolatron Start Bar incorporates an anti-repeat feature and is designed to require the release of all operator’s hand controls before an interrupted...
  • Page 4 Safety: The Nolatron Start Bar is not intended for use without adequate “point of operation” safety guards, which must be provided following OSHA regulations and ANSI standards to protect the operator. The operator must ensure the bar is properly installed, inspected and operated. Failure to comply could result in serious bodily injury and/or property damage.
  • Page 5: Installation

    Warning! It is necessary to locate and install the Start Bar in accordance with OSHA machine guarding distance calculations which can be found in 29 CFR 1910.217. Users must also install point of operation guarding devices, compliant with OSHA regulations, ANSI standards, and any other machine safety standard that applies to the specific industry such as light curtains, pressure mats, etc.
  • Page 6 Operation: The Start Bar will perform a system test before every machine cycle. The test cycle will require approximately one second to complete. Then the Ready indicator will light and a machine cycle can be started. In order to begin a machine cycle, both hand switches must be touched concurrently within a half a second.
  • Page 7 Normally, this requires a pair of positive guided relays. The normally closed contacts of the relays must be monitored by the ATD control. Please call Nolatron for technical assistance on how these relays are configured to operate in conjunction with the Start Bar.
  • Page 8 Wiring the Hold switch: An optional Hold switch can be used to allow the load to remain energized after the hand switches are released. This feature is useful for applications that have long machine cycles. The Hold switch is normally open and must not be closed until the operator can no longer reach into the point of operation.
  • Page 9 Safety Testing Procedure: After the Start Bar is installed, an initial safety test must be performed by a qualified person who is appointed by the employer. This testing procedure is used to ensure that the Start Bar has been wired and is functioning properly. The testing procedure should be carried out periodically and the machine must not be used if the Start Bar ever fails the test.
  • Page 10: Specifications

    The foregoing warranty is exclusive and in lieu of all other warranties of quality whether written, oral or implied. Nolatron is not liable for any damage or injury which may result from the use of its products.
  • Page 11 055040 Parts List for TB-2 4487 anti-tiedown control HS-115 optical hand sensor (model TB-2E) 055025 cast aluminum housing 055026 front access plate with gasket 055028 3/8" 6-32 black Phillips head screws (8pcs) 055031 5/8" 6-32 socket head screws (3pcs) 055040 mechanical hand switch assembly (model TB-2M) Optional parts not shown 30165...
  • Page 12 © 2018 Nolatron, LLC P/N: APPTB-2 Rev Date: 15-Feb-18 5198 Richmond Rd, Bedford Heights, OH 44146 Phone (717)564-33 Fax (216)274-9262 www.nolatron.com sales@nolatron.com...