Cool - Panasonic WH-MDC05J3E5 Operating Instructions Manual

Mono bloc air-to-water heatpump
Hide thumbs Also See for WH-MDC05J3E5:
Table of Contents

Advertisement

Available languages

Available languages

Menu
6.2
*
*

Cool

1,
2
To set various water & ambient
temperatures for cooling.
*
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
1
*
Only displayed when COOL mode is unlocked (This means when COOL mode is available).
2
Default Setting
Setting Options / Display
Heater ON/OFF Delay time for heater ON
Delay time for heater
0:30 min
to turn on
Heater ON/OFF Water temperature for heater ON
Setting of water
temperature to turn
-4 °C
on from water set
temperature.
Heater ON/OFF Water temperature for heater OFF
Setting of water
temperature to turn
-2 °C
off from water set
temperature.
Water temperatures for cooling ON
and T for cooling ON.
Water temp. for cooling ON
Cooling ON
temperatures in
Compensation curve
compensation curve
or direct input.
Water temp. for cooling ON Compensation curve
Input the 4
temperature points
X axis: 20 °C, 30 °C
(2 on horizontal X
Y axis: 15 °C, 10 °C
axis, 2 on vertical Y
axis)
• If 2 zone system is selected, the 4 temperature points must also be input for Zone
2.
• "Zone 1" and "Zone 2" will not appear on the display if only 1 zone system.