WARNING Never exceed 25 PSI during operation. Do not leave exposed to the elements, heat sources, or direct sunlight for extended periods. Sun light has adverse effects on the integrity of the tank plastic and thermal expansion from heat may increase the pressure well beyond 25 PSI. Do not interchange between mineral based fluid types and phosphate ester-based fluid types.
Before first use Read this manual and all warnings in its entirety. Identify the fluid type and expiration date of the fluid to be used in the tank. We suggest marking with a black permanent marker on a self-adhesive write-on label or clear cellophane tape affixed onto the tank in the silver square for contrast.
Page 6
Possible Contaminant Pump Barrel Entry Point Seal Pump Pump Cartridge Unit Check Plunger Valve Assembly Figure 1 JAN 16/19...
Maintenance Changing fluid types Changing between mineral based fluid types and phosphate ester-based fluid types is prohibited. The two configurations of this pump are not compatible with each other. Only use the fluid for which the pump is designated. Hose The corrugated hose should be checked before each use and replaced on-condition.
5. Cleaning 10 micron filter (anodized grey aluminum) is permissible 1 time through the following steps. A new filter P/N APEK9052 should be installed thereafter: a. Disassemble filter by unscrewing the two halves and removing the internal metal element and spring.
AP Tools LLC, its owner, contractors, vendors, and affiliates assumes no liability for any material loss or bodily harm arising from the use / misuse of this product. AP Tools LLC will only warranty its manufactured products for workmanship and / or defects by us.