Hardware
Installation

Electrical Data

115V~
NOTICE
The shape may be different according to its model.
Use Wall Receptacle
Standard 208/230V, 3-wire
grounding receptacle rated 15A
Standard 208/230V, 3-wire
grounding receptacle rated 20A
Standard 208/230V, 3-wire
grounding receptacle rated 30A
Standard 265V grounding
receptacle rated 20A
Standard 265V grounding
receptacle rated 25A
NOTICE
DO NOT USE AN EXTENSION CORD on 230,
208, and 230/208,265Volt units.
All wiring should be made in accordance with
local electrical codes and regulations.
Aluminum house wiring may pose special
problems. Consult a qualified electrician.
Hardware Installation
230V~
Power Supply
Use 15 AMP. time
delay fuse or 15 AMP.
Circuit breaker.
Use 20 AMP. time
delay fuse or 20 AMP.
Circuit breaker.
(2500W Heater ¡15Amp
Circuit Breaker)
Use 30 AMP. time
delay fuse or 30 AMP.
Circuit breaker.
Use 20AMP,time delay
fuse or 20AMP
Circuit breaker
(2000W Heater ¡15Amp
Circuit Breaker)
Use 25AMP,time delay
fuse or 25AMP
Circuit breaker
Power cord may include a current
265V~
interrupter device. A test and reset
button is provided on the plug case. The
device should be tested on a periodic
basis by first pressing the TEST button
and then the RESET button. If the TEST
button does not trip or if the RESET
button will not stay engaged,
discontinue use of the air conditioner
and contact a qualified service
technician.
Never push the test button during operation
Otherwise this plug can damaged.
This device contains chemicals, including lead, known
to the State of California to cause cancer, birth
defects, or other reproductive harm.
Wash hands after handling.
Do not remove, modify, or immerse this plug.
If this device trips, the cause should be corrected
before further use.
The conductors inside this cord are surrounded by shields,
which monitor leakage current.
These shields are not grounded.
Periodically examine the cord for any damage. Do not use
this product in the event the shields become exposed.
Avoid shock hazard! This unit cannot be serviced. Opening
the tamper-resistant, sealed portion of the unit voids all
warranties and performance claims. This unit is not intended
to be an ON/OFF switch.
• If unit equipped with cords and plugs as long as they are
installed with sub-bases, and the cord and plug are
enclosed within the sub-base.
• The sub-base must have means for permanent
connection.
• The sub-base must have an outlet for the connection of
the cord and plug.
• To complete the installation of this PTAC, there must be a
sub-base.