Sharp LC-60LE600U Service Manual page 43

Hide thumbs Also See for LC-60LE600U:
Table of Contents

Advertisement

1) Center Icon illumination
Error type
Center Icon illumination operation (1 cycle)
Lamp error
[Center Icon illumination]
Flashes once: Fast
H: On
L: Off
Temperature error
[Center Icon illumination]
Flashes 4 times
H: On
L: Off
Error Type
H: On
Panel power error
Flash 2 times
L: Off
LED flashing timing chart for error notification.
400ms
1600ms
Pins are microprocessor pins.
Judged by the ERR_PNL port. Confirmed after 10 consecutive
detections at 500 ms intervals (detected only when the backlight is
on).
[Released]
Execute AC_ON with [INPUT] and [VOL-DOWN] on the unit
down. Then execute the function of "L ERR RESET" in the
adjustment process mode menu.
Continuous illumination for 15 minutes.
NOTE: After five detection counts, the lamp cannot be activated.
Judged by monitoring temperature with the temperature sensor.
When the panel temperature is 63°C or more, caution is dis-
played. If the panel temperature is 65°C or more, error standby is
activated.
[Released]
Reduce the value of TEMP CAUTION (temperature caution
threshold) and TEMP SHUTDOWN (temperature protection
threshold) in the adjustment process mode menu.
Judged panel power supply by the DET_POW_port.
Conformed after 2 consecutive detections at 16mS intervals.
6 – 11
LC-60/70LE600U