36 inch built-in wood burning corner fireplace with optional outside air and glass doors
Hide thumbs Also See for 624WBCR:

Advertisement

Quick Links

M
ODELS
I
NSTALLATION
36 INCH BUILT-IN WOOD
BURNING CORNER
FIREPLACE WITH
OPTIONAL OUTSIDE
AIR AND GLASS
f i r e - p a r t s . c o m
DOORS.
624WBCL
C
ORNER
, O
PERATION AND
F
OR RESIDENTIAL
624WBCR
AND
F
IREPLACE
M
AINTENANCE
I
NSTALLATION
M
ANUAL
WARNING: THIS FIREPLACE
HAS NOT BEEN TESTED
WITH AN UNVENTED GAS
LOG SET. TO REDUCE RISK
OF FIRE OR INJURY, DO NOT
INSTALL AN UNVENTED GAS
LOG SET INTO FIREPLACE.
53D9051. Rev 1 03/03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 624WBCR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Monessen Hearth 624WBCR

  • Page 1 624WBCL 624WBCR ODELS ORNER IREPLACE NSTALLATION PERATION AND AINTENANCE ANUAL OR RESIDENTIAL NSTALLATION WARNING: THIS FIREPLACE 36 INCH BUILT-IN WOOD HAS NOT BEEN TESTED BURNING CORNER WITH AN UNVENTED GAS FIREPLACE WITH LOG SET. TO REDUCE RISK OPTIONAL OUTSIDE AIR AND GLASS OF FIRE OR INJURY, DO NOT f i r e - p a r t s .
  • Page 2: Table Of Contents

    ONGRATULATIONS You have chosen a fine woodburning fireplace. Your fireplace has been designed and built for years of heating and viewing enjoyment. Please take time to read this entire manual before installing or operating your fireplace. ABLE OF ONTENTS ....................... 2 ISTING AND PPROVALS ........................
  • Page 3: Mportant Nformation

    This fireplace is designed to sit directly on a combustible floor. The fireplace can be installed with zero clearances to combustible building materials at the side, back and top spacers. Only parts manufactured by Monessen Hearth Systems and labeled for use with this fireplace should be used in the installation of the fireplace except for special roof flashings that may be fabricated locally.
  • Page 4: Operation Guidelines

    NOTE: It is normal for a small amount of smoke to be released from the upper portion of the fireplace the first few times you use your new Monessen Hearth Systems fireplace. This results from an oil residue on the metal. Open a door or window to allow the smoke to escape.
  • Page 5: Clearances

    LEARANCES f i r e - p a r t s . c o m 53D9051. Rev 1 03/03...
  • Page 6: Fireplace Components

    - p a r t s . c o m MODEL NUMBER DESCRIPTION 624WBCL, 624WBCR Left or right end open fireplace. Includes wire firescreen, sealing flue damper and outside combustion air capability. When installed, outside combustion air can be connected to left side.
  • Page 7: Fireplace Installation

    IREPLACE NSTALLATION f i r e - p a r t s . c o m 53D9051. Rev 1 03/03...
  • Page 8: Chimney Components

    HIMNEY OMPONENTS When installing “E” series triple wall chimney system on the 624WBCL and B36LR, do not mix chimney system components other than those listed below. Maintain 2” airspace clearances to combustibles. Use same offset and rise chart for chimney when installing elbows. f i r e - p a r t s .
  • Page 9: Selectinga Location

    ELECTING OCATION CAUTION: Do not install fireplace over carpeting. This fireplace does not require any special foundation. If the fireplace is to be trimmed with large stane or brick facing, an adequate foundation is required to support these materials. Use figures 5 and 6 as a guide for selecting a location and determining the space required for the fireplace.
  • Page 10: Floor Protection

    LOOR ROTECTION All fireplaces installed over a combustible floor must incorporate a non-combustible hearth extension. It is required to protect the floor in front of the fireplace from both radiant heat and sparks. Hearth extension dimensions should be determined by using the chart below. use hearth extensions as illus- trated in figures 6, 10 and 11 or use an acceptable thickness of a durable non-combustible material with an equal or greater insulating value than K = .43 Btu in/ft -HR-Fº, or a thermal resistance that equals or exceeds...
  • Page 11: Clearances

    LEARANCES f i r e - p a r t s . c o m 53D9051. Rev 1 03/03...
  • Page 12: Fireplace Installation

    IREPLACE NSTALLATION f i r e - p a r t s . c o m 53D9051. Rev 1 03/03...
  • Page 13 IREPLACE NSTALLATION f i r e - p a r t s . c o m 53D9051. Rev 1 03/03...
  • Page 14 IREPLACE NSTALLATION f i r e - p a r t s . c o m OCATION ELECTION Unpack and check the fireplace and chimney for damage. If any items have been damaged, report this to your dealer. Before beginning the installation, be sure you have the proper parts in sufficient quantity. Refer to the Parts Diagram and List section of this manual for proper identification of parts.
  • Page 15: Chimney Installation

    HIMNEY NSTALLATION f i r e - p a r t s . c o m 3. Enclose the chimney where it passes through the living spaces to prevent contact with and possible damage to the chimney. 4. Install firestop spacers at each ceiling level. 5.
  • Page 16 HIMNEY NSTALLATION f i r e - p a r t s . c o m 53D9051. Rev 1 03/03...
  • Page 17: Chimney Offset Installation

    HIMNEY FFSET NSTALLATION NOTE: If you intend to have a total fireplace installation of more than 30 feet, you must use a chimney support at or below 30 feet to support the weight of additional chimney pipe. If it is impossible to nail the chimney support to the load bearing framing of the builing at the 30 foot level, the chimney support may be installed at a lower level if the height of the chimney above the support does not exceed 30 feet.
  • Page 18: Chimney Offset And Cap Installation

    HIMNEY FFSET AND NSTALLATION f i r e - p a r t s . c o m 53D9051. Rev 1 03/03...
  • Page 19: Ap Installation

    HIMNEY FFSET AND NSTALLATION f i r e - p a r t s . c o m 53D9051. Rev 1 03/03...
  • Page 20 HIMNEY NSTALLATION SC C ODEL HIMNEY : The proper height as previously explained is important to assure proper draft and safety. The PECIAL chimney cap extends the flue outlet four inches above the top of the last section of chimney. This should be kept in mind when determining the proper height for the chimney.
  • Page 21: Recautions Ecommendations

    & R UTSIDE OMBUSTION RECAUTIONS ECOMMENDATIONS NOTE: The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fireplace. Use the model OAC4 combustion air kit.
  • Page 22: Combustion Air Assembly

    OMBUSTION SSEMBLY OAC4 C ODEL OMBUSTION SSEMBLY 1. Remove the cover cap from the 4 inch outlet opening location on the left or right outside surface of the fireplace. DO NOT REMOVE THE COVER IF THE OUTSIDE AIR WILL NOT BE CONNECTED. 2.
  • Page 23: Gas Appliance Installation

    PPLIANCE NSTALLATION : Improper installation or operation of a gas appliance in this fireplace can allow unburned gas to leak ARNING out which will cause a fire or explosion hazard, or the release of poisonous carbon monoxide into the dwelling which can cause serious injury or death to its inhabitants.
  • Page 24: Trim Installation

    PPLIANCE NSTALLATION NSTALLATION The face of your fireplace may be left exposed or trimmed with any noncombustible material such as brick, f i r e - p a r t s . c o m stone or marble. See Figure 28. If a noncombustible trim is installed, be sure it is fastened snugly to the face of the fireplace.
  • Page 25 NSTALLATION INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE FOR 624WBCL AND 624WBCR NOTE: ON 624WBCL OR 624WBCR MODELS, NON-COMBUSTIBLE MAY BE INSTALLED TO THE TOP OF THE FIREPLACE OPENING. THIS FACING MATERIAL FIGURE 28 MUST BE SECURED AND SEALED TO THE FACE OF THE FIREPLACE. FAILURE TO PROPERLY SECURE AND SEAL NON-COMBUSTIBLE FACING MATERIALS TO THE f i r e - p a r t s .
  • Page 26: Fireplace Operation

    IREPLACE PERATION : If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an open ARNING position. (See additional operation information in section titled “Operation Guidelines”.) HICH OODS ARE Each wood species offers something different in aroma or heat value, and you should consider your needs and desires before building your fire.
  • Page 27 IREPLACE PERATION VS. F OSSIL UELS Compared to fossil fuels, a full cord of dry hickory weighs about two tons and is approximately equal in heating value to a ton of hard coal. On a pound basis, heavy hardwoods have about half the heating value of coal. The tabulation shows the relative densities and heat values of a variety of dry woods.
  • Page 28: Maintenance And Safety

    Make sure the chimney is clear from any accumulation of soot, creosote or any other debris, and that all joints are intact. Monessen Hearth Systems does not recommend chemical cleaners because some may contain elements that corrode the metal parts of the chimney or fireplace.
  • Page 29 This is normal and unavoidable. If the cracks become large enough or parts dislodge and metal behind the refractory is exposed, the refractory panels should be replaced with new panels that can be obtained from your Monessen Hearth Systems fireplace dealer. See Figure 34. LASS AINTENANCE For glass door maintenance, see instructions provided with the glass doors.
  • Page 30 25. Don’t clean the chimney with metallic devices or chemical cleaners. 26. Don’t use the fireplace or chimney for venting wood or coal burning heaters or inserts unless approved in writing by Monessen Hearth Systems . 27. Don’t put combustibles within 24 inches of the fireplace opening.
  • Page 31: Arts Iagram And Ist

    ARTS IAGRAM AND All repair part orders should be placed through your local dealer. To ensure prompt and accurate service, please provide the following information when placing a repair part order: Model number of your Appliance, Part Name, Part Number, and Quantity of parts needed. See Figure 34. Technical Service Department 2813 W.
  • Page 32 f i r e - p a r t s . c o m TTENTION PPLIANCE NSTALLER LEASE ETURN NSTRUCTION ANUAL ONSUMER 53D9051. Rev 1 03/03...

This manual is also suitable for:

624wbcl

Table of Contents