TrafSys Walker Wireless THM3020 Manual

TrafSys Walker Wireless THM3020 Manual

Wireless overhead thermal sensor

Advertisement

Quick Links

W
i
r
e
l
e
s
s
O
v
e
r
W
i
r
e
l
e
s
s
O
v
e
r
S
e
n
s
o
r
S
e
n
s
o
r
M
o
d
e
l
:
T
H
M
3
0
2
0
M
o
d
e
l
:
T
H
M
3
0
2
0

Introduction

The Traf-sys/Walker Wireless Wireless Overhead
Thermal Sensors are a discreet and highly
accurate solution to track foot traffic through a
given area or entrance. The counter consists of
two parts, a base and the sensor, and determines
traffic using heat signatures from customers'
heads; upon a heat signature crossing configured
IN/OUT lines, a count of the appropriate direction
is transmitted to the wireless transmitter.

Table of Contents

Introduction ..................................................................................................................... 1
Table of Contents ............................................................................................................ 1
Required Equipment........................................................................................................ 1
Mounting and Orientation ................................................................................................ 2
Single Sensor Entrance ............................................................................................... 2
Calibrating the Sensors ................................................................................................... 4
Required Equipment for Calibration ............................................................................. 4
Attaching the Setup Module......................................................................................... 4
Single Sensor Entrance Calibration ............................................................................. 6
Multiple Sensor Entrance Calibration ......................................................................... 14
Troubleshooting ............................................................................................................ 16
Thermal Issues .......................................................................................................... 16
Mounting Issues ........................................................................................................ 16
Software Issues ......................................................................................................... 16
Safety and Occupancy Issues ................................................................................... 16
LED Codes ................................................................................................................ 17
Appendix A: Sensor Base Wiring................................................................................... 18

Required Equipment

Traf-sys/Walker Wireless Thermal Sensor Configuration Software
Windows XP or later laptop PC with an available 9 pin RS-232 Serial Port.
THM3020S Setup Module (do not attempt to use any other setup module).
Straight and Philips head screwdrivers (not included)
Mounting bolts/screws (not included)
Wall mount bracket or ceiling mounting plate (optional; not included)
Wireless Transmitter and Power Supply (included in kit)
RJ-45 patch cables (included in kit)
Category 5 Ethernet cable for multiple sensor connection (not included)
Female to female RJ-45 Category 5 Ethernet jacks (two per sensor)
Cable/jack tester
Traf-sys/Walker Wireless, Inc | 190 Industry Drive - Pittsburgh, PA 15275
Ph: 888-815-6568 | Fax: 928-222-7279 |
h
e
a
d
T
h
e
r
m
a
l
h
e
a
d
T
h
e
r
m
a
l
www.trafsys.com
Page 1 of 18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Walker Wireless THM3020 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TrafSys Walker Wireless THM3020

  • Page 1: Table Of Contents

    Category 5 Ethernet cable for multiple sensor connection (not included)  Female to female RJ-45 Category 5 Ethernet jacks (two per sensor)  Cable/jack tester Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 1 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 2: Mounting And Orientation

    Figure 2 below illustrates a single sensor installation. Figure 2 Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 2 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 3 4. Connect the power supply to the wireless transmitter and the wireless transmitter to the master sensor via the black cable. The sensor receives Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 3 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 4: Calibrating The Sensors

    Windows XP or later laptop PC with an available 9 pin RS-232 Serial Port.  Traf-sys/Walker Wireless Thermal Sensor Configuration Software installed. (available at http://sw.trafsys.com/IRC3000/)  THM3020S Setup Module; see Figure 4 below (do not attempt to use any other setup module).
  • Page 5 See Figure 6 & 7 below. Figure 6 Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 5 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 6: Single Sensor Entrance Calibration

    Comms ID for the sensor with flashing lights. In a single sensor setup, using “1” will be safe. See Figure 8 below for illustration. Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 6 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 7 Figure 9 Figure 10 6. Press Next and the wizard should report that it has saved your settings successfully. Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 7 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 8 Press Finish to exit the wizard. See Figure 12 below for an illustration. Figure 12 Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 8 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 9 Menu and Advanced while in Figure 15 below you will see the Device Settings menu (opened by clicking the gear). Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 9 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 10 Figure 14 Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 10 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 11 The settings in this menu are crucial to the counter operating properly. See Figure 16 below for the correct Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 11 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 12 Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 12 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 13 See Figure 18 below for an illustration. Figure 18 16. Click the Permanent All sub-menu under Menu to make all settings persistent. Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 13 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 14: Multiple Sensor Entrance Calibration

    You will have to drag and drop the sensors into their necessary roles. See Figure 19 below. Figure 19 Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 14 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 15 5. In step 15, ensure that the configured count lines span across all of the sensors’ fields of view. As also shown in Figure 22 above. Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 15 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 16: Troubleshooting

    No automated people counting solution is 100% accurate, and applications of Occupancy and Safety would almost require Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 16 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 17: Led Codes

    This indicates that the counter is has not been configured and is at factory default address of 127. This is perfectly normal for a new unit and merely indicates that Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 17 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...
  • Page 18: Appendix A: Sensor Base Wiring

    LED flashing twice error (above) which can only occur on a master, although these errors may be seen together in certain circumstances. Appendix A: Sensor Base Wiring Traf-sys/Walker Wireless, Inc | 190 Industry Drive – Pittsburgh, PA 15275 Page 18 of 18 Ph: 888-815-6568 | Fax: 928-222-7279 | www.trafsys.com...

Table of Contents