Page 2
MANUFACTURED BY Moffat Limited PO Box 10001 Christchurch New Zealand (03) 389 1007 Fax: (03) 389 1276 WORLD-WIDE BRANCHES UNITED KINGDOM Blue Seal Units 6-7, Mount Street Business Park Mount Street, Nechells Birmingham B7 5QU (121) 327 5575 Fax: (121) 327 9711 UNITED STATES Moffat Inc 3765 Champion Blvd...
Contents Introduction ......................2 Installation ......................3 Before Connection Location Electrical Connection Water Connection (Auto Fill Models Only) Rack Width Stacking with Convection Oven Specifications.....................5 Operation ......................9 Description of Controls Condensation Channel Operating in PROVE Mode Bake-Off Problem Solving Hints Operating in HOLD Mode Cleaning and Maintenance................13 Trouble Shooting .....................14 Spare Parts .......................15...
Introduction We are confident that you will be delighted with your E85HLD PROVER / HOLDING CABINET, and it will become a most valued appliance in your commercial kitchen. A new oven can seem very complex and confusing at first glance. To ensure you receive the utmost benefit from your new Prover, there are two important things you can do.
25 mm / 1 ” Electrical Connection • E85HLD provers are supplied fitted with cords. Ensure unit is fitted with correct cord and plug. • To access the electrical connection terminal block, grounding lug and strain relief, remove the right hand side panel.
For this a stacking kit is required (part number 022299). • For installation of the stacking kit, refer to the instructions provided with the kit. These instructions also include the procedure for mounting the E35 convection oven on top of the E85HLD prover and stacking kit.
Specifications E85-8HLD Prover WATER ENTRY ELECTRICAL ENTRY Side Front Plan Electrical Connection 110-120 Volts A.C, 60 Hz, 1P+N+E, 1.65 kW, 14.5 A 220-240 Volts A.C, 60Hz, 1P+N+E, 1.65kW, 7.2A Cold Water Connection ¾” B.S.P. or ID hose (550kPa / 80psi maximum pressure) (Auto Fill Models Only)
Page 8
Specifications E85-12HLD Prover WATER ENTRY ELECTRICAL ENTRY Side Front Plan Electrical Connection 110-120 Volts A.C, 60 Hz, 1P+N+E, 1.65 kW, 14.5 A Cold Water Connection ¾” B.S.P. or ID hose (550kPa / 80psi maximum pressure) (Auto Fill Models Only)
Page 9
Specifications E85-8HLD Prover / E35 Oven 980 (30" Ovens) 880 (26" Ovens) WATER ENTRY ELECTRICAL ENTRY Side Front ELECTRICAL ENTRY Plan...
Page 10
Specifications E85-12HLD Prover / E35 Oven 980 (30" Ovens) 880 (26" Ovens) WATER ENTRY ELECTRICAL ENTRY ELECTRICAL ENTRY Side Front Plan...
Operation Operation Guide Description of Controls Function Unit is off PROOF Unit is in proving mode (indicator illuminates) HOLD Unit is in holding mode (indicator illuminates) Thermostat Temperature range 0 - 80°C. Indicator illuminates when the elements are cycling ON to maintain set temperature.
Place thawed products directly from the refrigerator into the pre-heated prover. Prove for 30-60 minutes dependant on product and food proving recommendations. 4. Bake Place proved product directly from the prover into the pre-heated oven. We recommend the Moffat E35 Turbofan Oven.
Operation Problem Solving Product collapses When using frozen dough which collapses or shrinks in the oven after proving, this is caused by too much proving. Reduce the proving time for the next batch. Dry product The dough piece in the prover should never be dry to the touch. A moist, firm and silky membrane should cover the dough piece during proving.
Operation Operating in HOLD Mode Ensure that power is supplied to the unit and the water trough is filled It is recommended that the cabinet operates empty before loading with product - Warm days up to 10 minutes - Cool days up to 30 minutes 1.
Cleaning Cleaning Guidelines Caution: ALWAYS TURN OFF THE POWER SUPPLY BEFORE CLEANING. THIS UNIT IS NOT WATER PROOF. DO NOT USE WATER JET SPRAY TO CLEAN INTERIOR OR EXTERIOR OF THIS UNIT. Cabinet Clean with a good quality stainless steel cleaning compound. Harsh abrasive cleaners may damage the surface.
Trouble-shooting Fault Possible Cause Remedy The prover does not operate / The mains isolating switch on the Turn on. start. wall, circuit breaker or fuses are “off” at the power board. The power switch on the cabinet Rotate switch. Indicator will is off.