Humandata LNX-205 User Manual

Lan multiplexer 2:1 x 2ch

Advertisement

Quick Links

LAN Multiplexer 2:1 x 2CH
LNX-205
User's Manual
Ver. 1.0
HuMANDATA LTD.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LNX-205 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Humandata LNX-205

  • Page 1 LAN Multiplexer 2:1 x 2CH LNX-205 User’s Manual Ver. 1.0 HuMANDATA LTD.
  • Page 2: Table Of Contents

    7.4. Read Setting Data ....................19 7.5. Write or Read setting data over the network ............. 21 8. Controller Command ................... 22 9. Virtual COM Port ....................25 10. Additional Documentation and User Support............. 26 11. Warranty and Compensation ................26 LNX-205 (Ver.1.0)
  • Page 3: Precautions

    Attention Item 7 notwithstanding, HuMANDATA cannot be held liable for the consequences arising from use of this product. HuMANDATA cannot be held liable for consequences arising from using this product in a way different from the uses described herein, or from uses not shown herein.
  • Page 4: Revision History

    Initial release  Introduction Thank you very much for purchasing our product LNX-205. LNX-205 is a LAN multiplexer to switch 2 LAN ports of 2 individual channels. 1. Product Configuration The following lists the product configuration of the LNX-205. LAN multiplexer (LNX-205) microSD card with USB adapter D-Sub 9pin M2.6 screw (#4-40 UNC is mounted)
  • Page 5: Product Summary

    LAN devices. LNX-205 supports PoE. That makes it possible to be powered via a LAN cable (PoE compatible HUB or other is required). It can also be powered by the AC adapter.
  • Page 6: Front Side

    Switching Port (x2) Switching Port (x2) LEDs Name (color) Function Power LED (red) Turn on during the power is supplied. Turn on during connecting with channel A or B Connection LED (red) A1, A2, B1, B2 common Port. LNX-205 (Ver.1.0)
  • Page 7: Rear Side

    Blink few seconds during reading process. System LED (red) Turn on when system is ready. microSD card access Turn on during accessing microSD card. BUSY LED (red) When it turned off, you can extract the card. LNX-205 (Ver.1.0)
  • Page 8: Specifications

    * There may be cases that these parts and specifications are changed. * Power saving function (suspend, standby, sleep and others) is not supported * Please use the microSD card that is included in the package. LNX-205 (Ver.1.0)
  • Page 9: Ac Adapter (Japan's Specifications)

    * There may be cases that this part and specifications are changed. 4.2. Optional Accessories Model Name Image Description Attachment for vertical direction ACC-027 JAN: 4937920801096 Attachment for horizontal direction ACC-028 JAN: 4937920801102 Attachment for DIN rail type B ACC-031 JAN: 4937920801256 Neodymium magnet set ACC-036 JAN: 4937920801539 LNX-205 (Ver.1.0)
  • Page 10: Power Supply

    4.3. Power Supply LNX-205 supports PoE function both A and B type as standard which make it possible to be powered via a LAN cable (PoE compatible HUB is required). It also can be powered by the AC adapter. 4.4. FG Terminal Please connect FG terminal with earth ground as necessary.
  • Page 11: External Contact Connector

    * #4-40 UNC screws are mounted by factory setting. You can change them to attached M2.6 screws. * COM A (pin No.7), COM B (pin No.9) is an option for DC 5V to 24V power input. If you need to change LAN port directly from open collector or transistor, please contact us. LNX-205 (Ver.1.0)
  • Page 12: Connection Examples

    6. Connection examples Change common port LAN or external network to LAN1 or LAN2. Channel A and B is independent from each other. LNX-205 (Ver.1.0)
  • Page 13: Setting Tool

    7. Setting Tool Setting tool supports to save and read network setting by a microSD card. This tool does not require installation. This is a screenshot from version 2.8 LNX-205 (Ver.1.0)
  • Page 14: Access Flow Of Microsd Card

    LNX setting tool. Write setting data Saving backup data of RD_DATA.TXT in the micro SD card. Possible to remove of the BUSY LED turn off microSD card SYS LED flicker (System start up) SYS LED turn on Ready LNX-205 (Ver.1.0)
  • Page 15: Function

    Read or write setting data over the network. LNX product and PC Network must be connected to the same network segment. Product select(S) Display product select window. File(F) -> Copy a display image to clipboard. Copy to clipboard File(F) -> Exit Terminate the application. Version(V) Display application version. LNX-205 (Ver.1.0)
  • Page 16 If you change the value, please avoid the following numbers. They are allocated to other function. 1-1024 Reserved for well-known ports Port number 9999 Reserved for telnet setup 14000-14009 Reserved for old redirector 30704 Reserved for remote control of user I/Os 30718 Reserved for configuration LNX-205 (Ver.1.0)
  • Page 17 Enable/Disable Remote IP address Enter the remote IP address of tunneling target. Remote Port number Enter the remote port number of tunneling target. Connection method Select connection method to the target. * Serial setting of LNX-205 is fixed. LNX-205 (Ver.1.0)
  • Page 18 After this idle gap time with no response from a serial device, data Idle gap time is packetized and transmitted to the target. The default setting is Trigger character Select packet size and set trigger character (hexadecimal digits). Check sum Select check sum size. LNX-205 (Ver.1.0)
  • Page 19 TCP keepalive time defines how many seconds LNX-205 waits during an inactive connection before checking its status. If the unit does not receive a response 7 consecutive times, it drops that TCP keepalive connection. Enter a value between 0 and 65 seconds. 0 disables keepalive.
  • Page 20: Write Setting Data

    7.3. Write Setting Data 1. Open Setting Tool for LNX series (LNX SETTING TOOL Ver*.*). Select “LNX-205 LAN Multiplexer 2:1 x 2CH”, and click “OK”. 3. Enter the setting such as network or serial. 4. Insert a microSD card to PC (A USB adapter is included with the product) Click “Saving data”.
  • Page 21 After the data is stored in the product, microSD card is not needed any more. The start-up time can be shortened if the microSD card is removed from the product. Please be careful not to detach the microSD card before BUSY LED is turned off. LNX-205 (Ver.1.0)
  • Page 22: Read Setting Data

    * If there is the same file name in the microSD card, the data will be overwritten. 3. Insert a microSD card to PC (A USB adapter is included with the product) Start the setting tool and click “Reading data”. Click “OK” in the confirmation dialog. Open the “RD_DATA.TXT” in the microSD card. LNX-205 (Ver.1.0)
  • Page 23 Setting data is loaded. LNX-205 (Ver.1.0)
  • Page 24: Write Or Read Setting Data Over The Network

    3. Click “Read data” or “Write data” * Even if some devices will be listed in the list and occur process time out. In this case, please change the PCs’ network setting to the same network segment as the product or using microSD card. LNX-205 (Ver.1.0)
  • Page 25: Controller Command

    2. ‘A1’: Select Ch.A LAN port 1 Format A1<CR> Function Ch.A LAN port 1(A1) is selected. Send A1<CR> e.g. A1,1<CR> * When selection of Ch.A LAN port 1 is completed. Response Password required<CR> *When port selection is disabled. LNX-205 (Ver.1.0)
  • Page 26 7. ‘B2’: Select Ch.B LAN port 2 Format B2<CR> Function Ch.B LAN port 2(B2) is selected. Send B2<CR> e.g. B2,2<CR> * When selection of Ch.B LAN port 2 is completed. Response Password required<CR> *When port selection is disabled. LNX-205 (Ver.1.0)
  • Page 27 VE<CR> Function Get the product version. Send VE<CR> e.g. Response LNX-205 Ver.1.0<CR> *When version is 1.0. 10. ‘PS’: Set a password for port selection Format PS,{PRAM1},{PRAM2}<CR> Set a password for port selection. The default password is set to Function “0000”. After setting a password other than “0000”, enable the port selection with the E command to enable the 0 to 4 command.
  • Page 28: Virtual Com Port

    You can use the software that creates Virtual COM ports on your PC. You can use the COM port to communicate to an IP address of LNX-205. Please refer to the "LNX series virtual COM port User's Manual" that are stored on the product supplied CD for details.
  • Page 29: Additional Documentation And User Support

    The following documents and other supports are available at https://www.hdl.co.jp/en/faspc/LNX/lnx-205 LNX SETTING TOOL  Virtual COM Port  Outline Drawing  … and more. 11. Warranty and Compensation Please refer to the following URL for the warranty. https://www.fa.hdl.co.jp/en/fa-warranty.html LNX-205 (Ver.1.0)
  • Page 30 LAN Multiplexer 2:1 x 2ch LNX-205 User’s Manual Ver. 1.0 ........August 30, 2021 HuMANDATA LTD. Address: 1-2-10-2F, Nakahozumi, Ibaraki Osaka, Japan ZIP 567-0034 Tel: 81-72-620-2002 (Japanese) Fax: 81-72-620-2003 (Japanese/English) URL: https://www.fa.hdl.co.jp (Japan) https://www.fa.hdl.co.jp/en/ (Global)

Table of Contents