Operation Details
• Cooling Operation Mode
When the room temperature is higher than the set temperature, it operates in cooling mode at the set
temperature, the set fan speed, and then it will be in automatically turn off when the room temperature
reaches the set temperature +0.5°C.
ROOM TEMP.
OPERATION START
SET TEMP. +0.5 C)
OPERATION STOP
SET TEMP. -0.5 C)
INDOOR FAN
OUTDOOR FAN/COMP
: SETTING FAN SPEED

Helpful information

Airflow speed and cooling capacity.
The cooling capacity indicated in the specification is
the value when the fan speed is set to high, and the
capacity will be lower at low or medium fan speed.
High fan speed is recommended when you wish to
cool the room quickly.
• After main power is on, Fan will start 7 seconds later.
Self-Diagnosis Function
'CH' will flash in the remote controller display when a problem occurs. Then please contact your dealer.
More 3 minutes
: LOW COOL OPERATION
20
: COMP ON
: COMP OFF