Summary of Contents for Air Torque AT1001U/PT1000B
Page 1
IMAT AT1001U-PT1000 B - E ISSUE: 02/18 INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTION MANUAL For AIR TORQUE ACTUATOR Model/Type: “AT1001U/PT1000 B” and “AT1001U R/PT1000B R” Double acting “D” and Spring return “S” “0°” “90°” Stroke...
Page 2
IMAT AT1001U-PT1000 B - E CONTENTS 1) GENERAL pag. 3 2) WARNING pag. 3 3) WORKING CONDITIONS AND TECHNICAL DATA pag. 3 4) OPERATING FUNCTION AND DIRECTION OF ROTATION pag. 4 5) INSTALLATION INSTRUCTIONS pag. 4 6) MAINTENANCE INSTRUCTIONS pag. 5 7) STORAGE INSTRUCTIONS pag.
Page 3
TORQUE. Working at high or low temperature can affect the personnel. For the use, installation and maintenance of life and the output torque of the actuator. Air Torque actuators it is recommended to comply to the • Operating Time (see Technical Data Sheet):...
5) ACTUATOR INSTALLATION INSTRUCTIONS fication label showing the serial number and all neces- The Air Torque actuator is a pneumatic device for the remote sary information on use, service, operation and product operation of industrial valves. The actuator will operate through designation.
Under normal conditions, the actua- tor requires only periodic observation to ensure proper operation. Maintenance (disassembly, maintenance and rebuilding) of AIR TORQUE actuators is allowed only to AIR TORQUE personnel or properly instructed personnel. In case of controversy the product guarantee will expire!
IMAT AT1001U-PT1000 B - E 11F* 24 11E* 03E 04E 19.1 19.0 02.1 16* 15* 09.1* 09.1* 19.5 19.6 11E* 23 11F* 03F PART UNIT PART UNIT PART DESCRIPTION PART DESCRIPTION N° Q.TY N° Q.TY OCTI-CAM (Stop arrangement) min. 5 SPRING (Cartridge) max.12 ANTI-BLOWOUT STOP SCREW...
Page 7
Remove O-rings external chamber connections (09.1) and discard if replacing all soft components. • Only for Model AT1001U/PT1000B R and AT1001U FA/ PT1000 B FA remove the nuts 04E, washers 03E, “O” rings 11E and screws 24E. Discard bearings when re- placing all soft components.
Page 8
• the spare parts and the lubricant used are suitable for the operating temperature of the actuator (see Air Torque technical data sheets). • Note: The lubricants suitable for the various operating tem- peratures (Standard, HT and LLT actuators) are available in Air Torque.
Page 9
IMAT AT1001U-PT1000 B - E Fig. 08 Fig. 10 Fig. 09 Fig. 09 A Fig. 11 C) Pistons assembly (Part N° 40 or 40F), Fig. 10,11,12,13 14 and 15: Fig. 12 • Only for Model AT1001U R/PT1000B R and AT1001U FA/PT1000 B FA install screws 23, O-rings 11F, washers 03F and nuts 04F.
Page 10
IMAT AT1001U-PT1000 B - E Fig. 14 Fig. 16 Air connection Fig. 15 Fig. 17 4° 4° Fig. 18 D) End cap (Part N° 30 for model AT1001U/PT1000 B, Part N° 32 for model AT1001U R/PT1000B R) and spring Side A cartridge (17) assembly, Fig.
F) Assembly of graduated ring and position indicator promise the functionality. (Part N° 19.0 and 19.1), Fig. 22 and 23: Contact Air Torque for any information and technical data- • Fix the graduated ring (19.0) to the body. sheets.