Red Arrow Slimline POLO POL14LEDEMS Installation Instructions Manual

Emergency bulkhead with microwave sensor

Advertisement

Quick Links

14W LED Emergency
Slimline POLO Bulkhead
with Microwave Sensor
Installation Instructions p.1
For models: POL14LEDEMS
This installation must be carried out by an electrician.
Please read these instructions carefully before installation.
Leave a copy for the user/maintenance engineer for future reference.

Specification

220-240V
13.5W
64pcs of 2835 SMD LED
4000K Colour temperature
1150 Lumen output
120° Beam angle
>82 Ra
Three years guarantee

Description of Microwave Sensor

The microwave sensor option offers presence
detection to provide automatic control of lighting
loads. It is installed inside the luminaire so does
not affect external aesthetics or the IP Rating.
Manual adjustments on the sensor allow it to be
individually tailored to suit your application.

Safety

This is a mains powered product. It is designed to be
installed by a qualified electrician and in accordance
with the applicable building and electrical
regulations. Before installation or maintenance the
electrical supply to the product must be isolated.
Installation Instructions
Remove the diffuser & trim from the base by rotating anti-
clockwise to unlatch, then pull away.
Loosen the three gear tray retaining screws, rotate the gear
tray anti-clockwise to align the screw heads with the large
aperture of the keyhole slots & remove the gear tray
away from the base. There is a retaining strap to assist with
installation.
Red Arrow Trading
Elsworth House, Herries Road South, Sheffield, S6 1QS
Prepare the mains supply cable & fixing points on the chosen
mounting surface ensuring it is able to retain the weight of
the luminaire.
Pass the mains supply cable through the hole & grommet
provided in the base, position the base to the mounting
surface & secure using the screws provided.
It is the installer's responsibility to ensure the fixing points
& cable entry point are appropriately sealed to maintain
the IP54 rating. Silicone bathroom sealant or equivalent is
recommended.
Route the mains supply cable to the terminal block on the
gear tray & terminate ensuring correct polarity is observed.
WARNING: THIS LUMINAIRE MUST BE EARTHED.
It is important that supply cables fitted to luminaires with an
electronic ballast do not run adjacent to leads connected to
the ballast output terminals so as not to affect radio
frequency interference suppression.
Secure the supply cable using the clamp provided in the base.
Refit the the gear tray & secure by retightening the screws.
Refit the diffuser & trim by placing over the base & rotating
clockwise until it locks into position.
Reconnect power supply & check for correct operation.
Luminaires fitted with electronic ballasts are exempt from
insulation resistance tests as this may cause damage to the
ballast.
Further Instructions for Emergency
version
In addition to the above instructions, a secondary "un-
switched" live supply should be fed to the luminaire, in line
with the "switched" mains supply. This "un-switched" supply
MUST be taken from the same phase as the "switched"
supply & MUST be wired at the switchboard so that upon
test, it is isolated at the same time as the "switched" supply.
T: 0800 195 0006
E: sales@redarrowtrading.com
F: 0870 043 3946
www.redarrowtrading.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Slimline POLO POL14LEDEMS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Red Arrow Slimline POLO POL14LEDEMS

  • Page 1 & MUST be wired at the switchboard so that upon away from the base. There is a retaining strap to assist with test, it is isolated at the same time as the “switched” supply. installation. Red Arrow Trading T: 0800 195 0006 F: 0870 043 3946 E: sales@redarrowtrading.com www.redarrowtrading.com...
  • Page 2 Once complete, ensure the normal supply is restored & that the LED charge indicator illuminates. • Log result / comments on the Testing Log Book (see next page). Red Arrow Trading T: 0800 195 0006 F: 0870 043 3946 E: sales@redarrowtrading.com www.redarrowtrading.com...
  • Page 3 FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL DISCHARGE Installed By: ..............Installation Date: ............Contact Details: ..................................................................Red Arrow Trading T: 0800 195 0006 F: 0870 043 3946 E: sales@redarrowtrading.com www.redarrowtrading.com Elsworth House, Herries Road South, Sheffield, S6 1QS...
  • Page 4 Rotate the dial to control the length of time the luminaire will stay on after occupancy has ceased. From ten seconds minimum (fully anti-clockwise) to 30 minutes maximum (fully clockwise). Red Arrow Trading T: 0800 195 0006 F: 0870 043 3946 E: sales@redarrowtrading.com...
  • Page 5 Make sure that the sensor is not adjacent to circulating air, heaters or lamps. • If the unit “false triggers” reduce the DISTANCE level to narrow the area of detection (rotate dial anti clockwise). Red Arrow Trading T: 0800 195 0006 F: 0870 043 3946 E: sales@redarrowtrading.com...
  • Page 6 Mega tested. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. We do not accept responsibility for any installation costs associated with the replacement of this product. We reserve the right to alter specifications without prior notice. Red Arrow Trading T: 0800 195 0006 F: 0870 043 3946 E: sales@redarrowtrading.com...

Table of Contents