About These Instructions
This document is part of the product. These instructions
describe how to install and connect the refl ector heating
systems ESO 180 H, and ESO 180 HL.
► Do not install or use the devices until you have read and
understood this document.
► Keep this document for reference throughout the service life
of the devices. Pass this document on to any new owner or
user.
The most up-to-date version of this document can be found at
www.kathrein-ds.com
Features
Flexible special heating mats with integrated heat insulation
and PTFE insulated heating elements
Good heat distribution due to an optimal fi t of the heating
mats on the refl ector
Element carrier of aluminium foil, self-adhesive foil strips at
the front
Thermal insulation made of bubble wrap with refl ective layer,
4 mm
Built-in sensor to additionally defi ne the heating temperature
via a control
Scope of Supply
4 heating mats with 3.5 m cable (H05RNF) and heating
temperature sensor
Mesh reinforced aluminium foil, 0.05 x 17 m
Adhesive fi lm (white) for covering the aluminium foil, 0.075 x
17 m
4 elliptical segments made of white adhesive foil for covering
the outer contours of the heating mats
8 x cable ties, 360 mm
Transport and Storage
► If possible, transport and store the heating mats in their original packaging.
► Protect the heating mats against moisture and mechanical damage.
► Transport and store the heating mats only in the permitted temperature range between -40 and +80°C. Make sure there is no
condensation build-up.
Functional Description
The electric heating prevents snow and ice formation on the antenna refl ector surface which may lead to interruptions in satel-
lite reception. The heating for the antenna consists of four special heating mats with integrated heat insulation and PTFE insulated
heating elements. After installation, the heating mats fi t on the refl ector in an optimum way and guarantee a good heat distribution.
Two of the heating mats have an integrated temperature switch that turns o the heating at 80°C so that the system can be directly
operated at 230 V/50 Hz. To ensure e cient operation, we recommend the use of a control unit for the ESO 180 H. The control unit can
be operated with the built-in sensor, but also without a sensor. Possible system components:
Operation without temperature
ESO 180 H
ESO 180 HL
Operation with temperature sensor
sensor
ESO 97 S
-
ESO 97 SL
ESO 97 SL ESO 99 S
1 / 4
ESO 180 HL: for exposed loca-
tions, with double the heating
power compared to ESO 180 H
(L = increased performance).
Operation without control possible
YES
A control unit is mandatory for
operating the ESO 180 HL. For this
purpose, the required temperature
sensor is built into the heating mat.

Advertisement

loading
Need help?

Need help?

Do you have a question about the ESO 180 H and is the answer not in the manual?

Questions and answers

Summary of Contents for Kathrein ESO 180 H

  • Page 1 Two of the heating mats have an integrated temperature switch that turns o the heating at 80°C so that the system can be directly operated at 230 V/50 Hz. To ensure e cient operation, we recommend the use of a control unit for the ESO 180 H. The control unit can be operated with the built-in sensor, but also without a sensor.
  • Page 2 Intended Use ESO 180 H and ESO 180 HL (performance-increased version) are refl ector heaters for the CAS 180 antenna. They are used to prevent snow and ice formation on the antenna refl ector surface which could lead to interruptions in satellite reception. Any other use, or failure to comply with these instructions or documentation and instructions enclosed with the devices, will result in voiding of warranty and guarantee.
  • Page 3 4. Run the mains cable from the bottom through the corresponding screw connection into the control device. 5. Test the heating for contact resistance and insulation resistance (R) before connecting the cables in the control cabinet. ESO 180 H ESO 180 HL Target value 36.6 –...
  • Page 4 35792 Löhneberg-Obershausen Germany Phone: +49 6477 612 310 1 Fax: +49 6477 612 302 0 Email: service-kathrein@autronic-service.de Technical Data ESO 180 H ESO 180 HL Type | Order No. 237500004 237500006 Suitable for satellite antenna CAS 180 Permissible ambient temperature °C...

This manual is also suitable for:

Eso 180 hl237500004237500006