• Store the Pump Base and Reservoir Patch at temperatures between -10°C (14°F) and 55°C(131°F). Charge PDM The PDM requires an AC adapter with Fully charged an output of DC 5.0V Charging Not charging Battery low Battery empty Medtrum Simplifying Diabetes...
3. Select language and country 4. Set time and date Note: You can only change the date and time when there is no activated Reservoir Patch. 5. Bolus Calculator Refer to Page 5 Medtrum Simplifying Diabetes...
Page 4
9. Enter Pump Base SN Main Menu ➔ Settings ➔ General ➔ Display Main Menu ➔ Patch ➔ Pump Base SN It is recommended for new users to set backlight time as to enter SN manually ------ 2 minutes Medtrum Simplifying Diabetes...
24 Hour Total 6. Tap to save the settings Note: Recheck all the numbers you entered to make sure that they are the intended values. 3 . Select a Basal Pattern Main Menu ➔ Basal ➔ Select Pattern Medtrum Simplifying Diabetes...
2. Set up the Bolus Calculator Turn on/off the Bolus Calculator • Set IC ratios • Set Insulin Sensitivity • Set BG target • Set IOB Time (Active Insulin Time) • 3. Normal, Extended and Combo Bolus Medtrum Simplifying Diabetes...
Connect Pump Base and Reservoir Patch Main Menu ➔ Patch ➔ New Patch Insert the hooks and connecter on the The pump will beeps Reservoir Patch all the four times way into the slots of the Pump Base. Medtrum Simplifying Diabetes...
Page 8
4. Push the plunger 5. Slowly fill the Reservoir until you see a drop with insulin of insulin at the tip of the needle Prime the Pump Press needle button Do not start priming before the needle button is pressed. Medtrum Simplifying Diabetes...
Page 9
4. Run your finger around the . Peel off the adhesive liners 1. Remove the safety lock the skin entire edge of the adhesive pad 5. Press the needle button Start Insulin Delivery with one quick motion to completely insert the needle Medtrum Simplifying Diabetes...
Purple ring represents the Purple and extend Bolus, the deep purple dark purple part indicates the progress of ring History delivery. Main Menu ➔ History Red ring represents the delivery Red ring suspend status. Medtrum Simplifying Diabetes...
Slide to deliver Main Menu ➔ Bolus ➔ Manual bolus Normal Bolus Set Bolus dose Extended Bolus Set duration Set Bolus type Combo Bolus Tap blue/purple plus sign to set proportion of Normal part and Extended part Set duration Medtrum Simplifying Diabetes...
Main Menu ➔ Bolus ➔ Bolus Calculator Normal Bolus Enter BG or Carb, or both Extended Bolus Set duration Combo Bolus Set Bolus dose and Bolus type Tap blue/purple plus sign to set proportion of Normal part and Extended part Set duration Medtrum Simplifying Diabetes...
Suspend & Resume A Bolus is being delivered Bolus Suspend Main Menu ➔ Suspend No Bolus is being delivered Resume Main Menu ➔ Resume Medtrum Simplifying Diabetes...
• Discard the old Reservoir Patch according to your local waste disposal regulations. Do NOT discard your Pump Base. It is reusable. Warning: Once the Patch is removed from the skin, do not attempt to press the needle button again. Doing so will result in injury. Medtrum Simplifying Diabetes...
Name Rate Duration % or Heavy Exercise : % or Medium Exercise : Light Exercise % or : Sick % or : Temp 1 % or : Temp 2 % or : % or Temp 3 : Medtrum Simplifying Diabetes...
Page 18
: : 1 U : 1 U : mmol/L : : BG Target (mmol/L) Max Bolus: __________________________U Start Time Low Limit High Limit Active Insulin Time: _______ : _______ : : : : : : : Medtrum Simplifying Diabetes...
Page 19
-Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Medtrum Simplifying Diabetes...
Page 20
RF warning for Portable device The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. FCC ID Pump Base (MD0201) FCC ID: 2AARU-MD0201 PDM (FM-018) FCC ID: 2AARU-FM018 Medtrum Simplifying Diabetes...
Page 21
Medtrum Technologies Inc. 7F, Building 8, No. 200, Niudun Road Shanghai 201203, China Tel: +86-21-50274781 Fax: +86-21-50274779 Medtrum B.V. EC REP Nijverheidsweg 17 5683 CJ Best The Netherlands Tel: +31(0) 499745037 This product complies with Directive 93/42/EEC (MDD) and Directive 2014/53/EU (RED).
Need help?
Do you have a question about the TouchCare MD0201 and is the answer not in the manual?
Questions and answers